CyberView  X5

 

         

User’s   Manual

 

 

Summary of Contents for CyberView X5

Page 1: ...CyberView X5 User s Manual ...

Page 2: ...r installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on ...

Page 3: ... Slides into the Holder Loading 135 Film and Slide Holder into Scanner Additional Features How to Scan Film and Slides STEP 1 Acquire Driver STEP 2 Select Film Type STEP 3 Optional Prescan STEP 4 Set Scan Settings STEP 5 Set Scan Preferences STEP 6 Scan STEP 7 Exit User Interface I Main Window Area II Preview Window Area Image Adjustment III Active Frame Setting Area Technical Support 4 7 8 9 10 1...

Page 4: ...ty USB 2 0 Cable GENERAL GUIDANCE Only use the supplied USB Cable Connect the computer to the scanner directly using the USB 2 0 cable For systems using USB 3 0 USB C and USB mini port a Hub may be required please see Connectivity issues with my new scanner If your situation requires a longer USB cable use only cables 6ft or less in length do not use a cable extender Also for best connectivity on ...

Page 5: ... to within this range before turning it on Operating Ambient Humidity Range 15 to 76 relative humidity non condensing Note If the scanner is stored or to be transported in cold temperature and then brought into a warm humid environment condensation may occur WARRANTY INFORMATION NOTICE Pacific Image warrants this product to be free from defects of material and workmanship for 1 year from the date ...

Page 6: ...QUICK INSTALLATION GUIDE ...

Page 7: ...ownload location Double click the CyberView icon to open the zipped file Click on the CyberView X_Windows installer to begin the installation follow the onscreen prompts MAC Download the driver from the above link then click on the CyberViewX_Mac file in the downloads folder this will create a CyberView removable drive icon on the desktop open the CyberView drive and drag the CyberView icon into t...

Page 8: ...it may be necessary to power off or if there is no on off switch disconnect the other scanner from the USB port for the Film scanner to work properly this does not apply if the device connect via Wi Fi QUICK INSTALLATION GUIDE Installing Hardware a Connect the slide scanner to a power source 1 Locate the power switch on the front of the scanner Make sure the scanner is TURNED OFF 2 Plug the AC ada...

Page 9: ...Loading 120 film into the holder ...

Page 10: ...er continued Note Orientation of scanner in the diagrams is from the front of the unit Take note of the curved edge of the 120 film holder also facing towards the front of the scanner for correct orientation when loading the scanner ...

Page 11: ...e tab to the closed position e Insert the film holder into the scanner from the left or right side into the small opening Push the holder inside until you feel it hit a stop then scan After the scan is done push the holder farther into the scanner until it hits another stop and scan again Repeat until the end of the holder Make sure that the orientation of white arrows on the holder correspond wit...

Page 12: ...angle arrow on the scanner 2 Set Scan settings and preferences See Page 13 Loading 135 film and slide holder into the scanner Insert the film holder into the scanner from the left or right side into the small opening Push the holder inside until you feel it hit a stop then scan After the scan is done push the holder farther into the scanner until it hits another stop and scan again Repeat until th...

Page 13: ...e fi lm type to be scanned Positive Negative or B W Black and White c Once you have selected a fi lm type you will have the option to select the frame sizes for the various 120 format films after you have inserted the fi lm holder into the unit NOTE The 135 fi lm will be auto detected a frame selection is not necessary ...

Page 14: ...omplete the image will appear in the CyberView interface 3 When the image appears on the screen select the Final scan icon to scan the fi le into a folder on the hard drive 3a Editing of the prescanned image before saving can also be done by clicking on the Image Adjustment icon for more see Advanced scanning options Page 23 STEP 4 Set Scan Settings After clicking on the Scan from the menu then cl...

Page 15: ...The scanning software has the capability of selecting 8 bit color mode or 16 bit color mode when scanning This will produce 24 or 48 bit color images 8 bits or 16 bits per Red Green and Blue color channels Example 8 bit mode 8 Red 8 Green and 8 Blue for a total of 24 bit color 16 bit mode 16 Red 16 Green and 16 Blue for a total of 48 bit color Scan Mode Normal mode produces a scan in jpeg format w...

Page 16: ...HOW TO SCAN continued STEP 5 Scan Setting Reference ...

Page 17: ...artridge User Defined Start Number Enter a specific start number 5 Choose the fi le type TIF or JPG TIF uncompressed or JPG Compressed Choose image quality for JPEG 20 100 100 offers the least amount of compression HOW TO SCAN continued Set Scan Preferences Continued Advanced Settings Reference ...

Page 18: ...HOW TO SCAN continued Set Scan Preferences Continued Default Scan Area Reference ...

Page 19: ...nned images will be saved to the directory location set previously the factory default locations are Windows C Users YOUR NAME Documents MAC Mac HD Users YOUR NAME Pictures CyberView Images STEP 7 Exit Select Scan Exit to close the driver Scanned image fi les can be open edited with any image editing software ...

Page 20: ...USER INTERFACE ...

Page 21: ...e Frame Setting Area Floating Window I Main Window Area Fixed Windows Menu Commands Scan Prescan Prescan Current Frame Pre scan the existing slide Scan Scan Current Frame Scan Selected to File Scan All Menu Commands Preview overview Zoom Rotate Flip features Preference See Scan Setting See Page 13 Exit Closes the CyberView X5 user interface ...

Page 22: ...Menu Commands Image Adjustment a Image Adjustment 1 Variations Generates different views of image with options to make changes to highlights mid tones etc ...

Page 23: ... too dark use the Brightness slider in the Color Balance window to adjust the image by selecting the slider in the center and moving it to the right The image s After view becomes lighter Select OK to accept the changes which will be sent to the scanning hardware This can also be used to adjust each of the functions in Color Balance by contrast saturation and specific color ranges of cyan magenta ...

Page 24: ...er in the Curves and Levels window can be made to correct the image Selecting the Gray slider in the center and moving it to the left will result in changes in the After view resulting in a lighter image Once the adjusted image is acceptable select OK to send changes to the scanning hardware The same method can also be used to adjust each color channel independently using the channel drop down men...

Page 25: ...re has been saved These files may be downloaded from our website About Displays system information including operation system CPU product information including product name model name hardware version firmware version software version device information including interface and optical resolution Function Bar Diagram Please select your film type and brand from the toolbar Negative Positive also kno...

Page 26: ... Accesses the image adjustment area after a Prescan has been performed Press drop down button for more options Left Return arrow Ejects the film to the left Left arrow Reverses the film one frame to the left Right arrow Advances the film one frame to the right Right return arrow Ejects the film to the right Go To You can select which frame to move to in the strip Preference Accesses the scan setti...

Page 27: ...a the image will reduce by half with every click until the lowest multiple 25 is reached Rotate 90 Left To rotate the image counter clockwise 90 degrees Rotate 90 Right To rotate the image clockwise 90 degrees Flip Horizontal To Flip the image 180 degrees horizontally Flip Vertical To Flip the image 180 degrees vertically Revert Discard all modifications and restores the image back to the original...

Page 28: ...II Preview Window Area Fixed Windows Continued You can select the ruler measurement unit in cm px by clicking the upper left corner ...

Page 29: ...cted to scan if you see Selections 2 or higher indicates Multiple scan areas on one slide ex II I II III Scan Setting Area Floating Windows Normal mode ex I to input the basic parameter to scan including scan resolution film size color depth Advanced mode ex II Allows you to input the parameter of scan output scan resolution Apply to All Applies settings made in this window only to all frames ...

Page 30: ...d Scan Mode Normal Scans using normal speeds Fast Scans 30 faster Quality Scans slower for more detailed images such as optical and dental x rays DPI Set your scanning resolution Color Depth 8 or 16 bits per color Channel resulting in a 24 or 48 bit image ...

Page 31: ...TECHNICAL SUPPORT CyberView For more information on our film scanners please visit Pacific Image Electronics For Support and driver updates Driver and Firmware updates Contact Us ...

Reviews: