background image

Model Number:

PQ6830AB, PQ6830AW

PQ6836AB, PQ6836AW

Read all instructions before operating the range hood.

PACIFIC RANGE HOOD

OPERATING INSTRUCTION

Airflow  Control   Technology

TM

C  

www.2pacific.com

XP022665(2)

Summary of Contents for PQ6830AB

Page 1: ...odel Number PQ6830AB PQ6830AW PQ6836AB PQ6836AW Read all instructions before operating the range hood PACIFIC RANGE HOOD OPERATING INSTRUCTION Airflow Control Technology TM C www 2pacific com XP022665 2 ...

Page 2: ...al Duct Cover P13 P15 Surface Maintenance P19 Table of Content www 2pacific com Product Functions Performance Specification Chart P4 Product Dimension P7 Circuit Diagram P6 Part Supplied P5 P9 P10 P11 List of Materials P8 Installation Procedures Wall Mount Installation Procedures Under Cabinet Installation Guidelines ...

Page 3: ... a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product damage serious personal injury or death CAUTION Caution means that failure to heed this safety statement may result in minor or moderate personal injury property or equipment damage WARNING To reduce the risk of fire or elect...

Page 4: ...wl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction exhausting of gases through the flue chimney of fuel burning b Sufficient air is needed for proper combustion and...

Page 5: ... standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qualifi ed electrician if you are not sure the range hood is properly grounded Do not have a fuse...

Page 6: ... Size PQ6830AB AW PQ6836AB AW 9W LED x 1 Under Cabinet Wall Mounted 1200 CFM 7 Round Verntical 120V 60Hz 4A 340W 29 3 4 x 18 7 8 x 12 1 8 35 7 16 x 18 7 8 x 12 1 8 290 390 CFM Black Glass Stainless Steel White Glass Stainless Steel Model Maximum CFM 1 Memory function to remember the last used fan and light settings 2 3 min and 5 min automatic delay off 3 Built in timer 4 Built in clock 5 Airflow C...

Page 7: ...Parts Supplied 5 www 2pacific com 1 7 Collar 1 Mounting Bracket 1 Blower Housing 2 Baffle Filter 1 Bottom Panel 1 Glass Touch Control 1 LEDStrip 1 Oil Tray 1 Hood Body ...

Page 8: ...Circuit Diagram 6 www 2pacific com MOTOR MOTOR LED LOGO LED Blue Blue Brown Brown Black Black White White Red Red Red Red Yellow Yellow Yellow Yellow Yellow Yellow Yellow ...

Page 9: ...rawing Cabinet Wall 7 www 2pacific com Installation Specifications Mounting Template Top Side Front Back 30 29 3 4 3 1 8 8 11 16 9 11 16 9 1 16 10 1 4 29 3 4 35 7 16 29 3 4 35 7 16 1 3 4 11 5 16 12 1 8 11 36 35 7 16 ...

Page 10: ...ate STANDARD CONFGURATION 8 www 2pacific com 5x24x1T Washer 1 1 2 Wood Screw M4x8 Round Head Screw HARDWARE PACKET CONTENT 4 8 6 3 Bracket Support Bracket Hardware Packet Part Supplied 3 16x2 Duct Cover Upper Bracket Wall Bracket Bottom Duct Cover Lower 1 1 1 2 1 1 2 Wood Screw M4x8 Round Head Screw 2 4 6 M4x8 Black Screw Flat Head Screw ...

Page 11: ...e maximum is 20 1 2 inches FIG 3 Suggest to close windowdoor before using hood FIG 1 Avoid left right or front dropped inclination FIG 2 Install the range hood and exhaust duct to the plastic collar and seal with metal tape 6 inches diameter exhaust duct is available but it might impact the suction efficiency 3 Exhaust duct 2 Mounting Height and Position 1 Location FIG 1 FIG 2 ...

Page 12: ...mounting template from the wall place the main bracket on the wall adjust the level and use 6 1 1 2 wood screws to screw the installation bracket on the wall 15 3 Locate the wooden beam and mark the location 650 50 70 130 150 130 70 50 29 15 16 35 5 8 Min 760mm 905mm Min 381mm 4 Measure the Installation Bracket Location Take out the Installation Bracket and the Installation Bracket Mounting templa...

Page 13: ...ight and one for left 10 Use 4 M4x8 round head screws to screws the collar on the top of hood 11 Install duct work and seal with aluminum duct tape 12 Remove the protective film from oil tray and install it on the lower side of appliance 14 Plug the appliance for a test run 8 Use the two holes under backside to hang the appliance on the installation bracket 15 Turn on the light and you can open th...

Page 14: ...81mm 5 Tear off the installation bracket mounting template from the wall place the main bracket on the wall adjust the level and use 6 1 1 2 wood screws to screw the installation bracket on the wall Foam Strip 6 Take out the foam strip from the accessory bag and stick it on the appliance under back side Installation Procedures Wall Mount 4 Measure the Installation Bracket Location Take out the Ins...

Page 15: ...liance 13 Plug the appliance for a test run 14 Turn on the light and you can open the deflect panel When the panel is open please take down the baffle filters and re install the filters after remove the protective film from those filters 9 And use 2 1 1 2 wood screws to screw the appliance on the wall 7 Use the two holes under backside to hang the appliance on the installation template 8 Fix the s...

Page 16: ...over bracket to wall below ceiling or soffit using 2 1 1 2 wood screws Optional Duct Cover 30 36 Model P1C 0068 Note P1C 0068 is not supplied in the package To order it please visit us online at www 2pacific com or call 888 833 8833 P1C 0068 Duct cover Min Max www pacifichoods com 718 633 3688 ...

Page 17: ...com 2 Attach the bottom bracket to the top of hood by securing the 6 M4x8 black screws for each side 4 Then extend inner top duct cover upwards and secure to duct cover bracket using 2 M4x8 round head screws 3 Remove the protective film from the duct cover surface ...

Page 18: ...at the lock function is on unlock the screen Press the to change lighting level from 2 1 off Press to increase fan speed from off 1 2 3 4 If hood is Off and is pressed fan will turn on Speed 1 Press to decrease fan speed from 4 3 2 1 off If fan is on Speed 1 and is pressed fan will power Off When ACT is enabled the fan speeds will be reduced as follows 1 390 CFM 2 290 CFM While the fan is on press...

Page 19: ...be disappeared and then resume the original operating status Or press the On Off button to turn off the fan and lights Alarm Operating Instructions 17 www 2pacific com Timer 5 Clock settings The display time on the screen is 12 hour clock At the first time delivery power it automatically display 12 00 Press for 3 seconds to enable the clock setting If no buttons is touched for more than 6 seconds ...

Page 20: ...The usage of ACT may not be necessary for your installation Please check your local codes for CFM restrictions With the hood off press and hold the and simultaneously for 3 seconds fan speed indicators illuminate for 3 seconds to show current setting Under the ACT verification mode press to enable setting mode If no button is touched for more than 6 seconds while the hood is in alarm setting mode ...

Page 21: ... often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood to prevent grease from accumulating the surface temperature in the kitchen Remarks 1 The range hood must be turned on every time before cooking to ensure maximum ventilation effect If there is damage to the power cord removing 2 Changing the p...

Page 22: ...connecting properly Check the power connection with the unit is connected properly The switch board or control board wirings are disconnected Make sure the wirings at the switch board and control board are connected properly The switch board or control board is defective Change the switch board or control board The wires on control board are loose Make sure the wires on the control board are conne...

Page 23: ...registration PACIFIC KITCHEN LIFE 390 Kansas St San Francisco CA 94103 888 833 8833 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warranty coverage should you need service Ownership verification for insurance purposes Notification of product changes or recalls To order parts visit us online at www 2pacific com or call us at 888 833 8833 www pacifichoods com ...

Page 24: ...排油煙機使用說明書 型號 使用前 請先詳細閱讀此說明書 太 平 洋 油 煙 機 PQ6830AB PQ6830AW PQ6836AB PQ6836AW Airflow Control Technology TM C www 2pacific com XP022665 2 ...

Page 25: ...P1 P12 P14 P15 P16 目 錄 www 2pacific com P3 P2 P6 P4 P5 P9 P10 P7 P8 P13 P14 安裝步驟 選配風管飾板 功能操作 P11 P12 故障排除 產品保養與清潔 功能簡介 性能規格表 安裝尺寸 安裝原則 爆炸圖 規格線路圖 安裝步驟 櫥櫃式 安裝步驟 壁掛式 配件說明 ...

Page 26: ...時鐘功能 5 ACT 專利風量控制技術 可依照地區法規調整風速設定 性能規格表 額定電壓 顏色材質 LED 照明 機 型 安裝方式 重量 Kg Ibs 排風量 CFM ACT 額定功率 機箱尺寸 英吋 風管口徑 PQ6830AB AW PQ6836AB AW 9W LED 燈條x1 櫥櫃式 壁掛式 7吋上出風 120V 60Hz 4A 340W 29 3 4 x 18 7 8 x 12 1 8 35 7 16 x 18 7 8 x 12 1 8 黑色玻璃 不鏽鋼 白色玻璃 不鏽鋼 24 9 54 78 290 390 CFM 27 2 59 84 1200 CFM ...

Page 27: ...爆炸圖 2 www 2pacific com 1 出風口 1 吊掛片 1 風胃 2 不鏽鋼濾網 1 煙罩 1 觸控開關組 1 LED 燈 1 油杯 1 機箱 ...

Page 28: ...規格線路圖 3 www 2pacific com MOTOR MOTOR LED LOGO LED Blue Blue Brown Brown Black Black White White Red Red Red Red Yellow Yellow Yellow Yellow Yellow Yellow Yellow ...

Page 29: ...產品尺寸圖 上視圖 側視圖 正視圖 後視圖 櫥櫃 壁式 4 www 2pacific com 安裝尺寸 安裝尺寸圖 30 29 3 4 3 1 8 8 11 16 9 11 16 9 1 16 10 1 4 29 3 4 35 7 16 29 3 4 35 7 16 1 3 4 11 5 16 12 1 8 11 36 35 7 16 ...

Page 30: ...1 1 1 1 1 1 1 2 1 櫥櫃開孔 尺寸圖 1 吊掛片 安裝尺寸圖 主機吊掛片 輔助吊掛片 螺絲包 5 www 2pacific com 風管飾板 上 風管飾板 下 風管吊掛片 固定片 墊片 5x24x1T 吋木螺釘 1 1 2 圓頭螺絲 M4 x 8 3 3 8 6 1 1 1 2 配件 選配 風管飾板 P1C 0068 1 1 2 木螺釘 M4x8 圓頭螺絲 2 4 6 M4x8 黑色螺絲 扁平頭螺絲 3 16 2 標準配置 螺絲包內容 ...

Page 31: ...15 min 20 1 2 max 傾 斜 抽油煙機安裝位置如在窗上或附近有太多門窗 開動抽油煙機前先關閉門窗 圖1 1 周圍環境 抽油煙機安裝高度 抽油煙機機體應保持左 右水平避免油杯積油溢出 圖2 量度安裝高度應從機器最低點垂直量度至爐頭正上方 最低15吋最高20 1 2吋 圖3 風喉必須配合本機出風管接頭之直徑 7吋 及避免太多彎位 以免影響抽風效果 可以安裝6吋風管接頭 但會影響抽風量 將排風管安裝至風管圈並使用金屬膠帶固定 2 安裝高度和機體位置 3 風喉 ...

Page 32: ...81mm到520mm 之間 30 機器 安裝寬度最小29 15 16 760mm 36 機器 安裝寬度最小35 5 8 905mm 4 測量吊掛片位置 從附件包內拿出吊掛片安裝尺寸圖 將尺寸 圖貼到牆面上並依照圖面指示鑽孔 5 撕下尺寸圖 將吊掛片放置在牆面上 調整水 平後並使用 6 1 1 2 木螺釘將固定片鎖在牆壁 上 15 3 尋找壁面的支撐點並標註 650 50 70 130 150 130 70 50 7 www 2pacific com 29 15 16 35 5 8 Min 760mm 905mm Min 381mm ...

Page 33: ...和鑽洞 完成後撕下尺寸圖 7 將機器的保護膜全撕除 9 用單手撐住機器 再由上方使用 3 3 16x2 扁平頭螺絲鎖及5x24x1T墊圈 固定於櫥櫃 右邊2個 左邊1個 11 接上鋁管 使用膠帶密封周圍 12 將油杯上的膜撕除後 裝上機器底部 13 插上電源後測試所有功能是否正常運作 8 將機器掛上主機吊掛片 8 www 2pacific com 14 測試完成後開啟照明 喚醒導流板 當導流板 開啟後 請拿下濾網並撕除保護膜後裝回 10 使用 4 M4x8圓頭螺絲 鎖上排風管 ...

Page 34: ...器 安裝寬度最小29 15 16 760mm 36 機器 安裝寬度最小35 5 8 905mm 5 撕下尺寸圖 將吊掛片放置在牆面上 調整水 平後並使用 6 1 1 2 木螺釘將固定片鎖在牆壁 上 泡棉條 6 將附件包內泡棉條拿出 貼在機器後方 如圖 安裝步驟 壁掛式 3 尋找壁面的支撐點並標註 4 測量吊掛片位置 取出附件包內的主機吊掛片 依安裝高度在牆 面上作記號 650 50 70 130 150 130 70 50 9 www 2pacific com 15 29 15 16 35 5 8 Min 760mm 905mm Min 381mm ...

Page 35: ...4x8圓頭螺絲安裝7吋出風口 7 將機器吊掛上去 8 使用 2 M4x8圓頭螺絲將輔助吊掛片鎖固於機器 上 方 10 www 2pacific com 12 將油杯上的膜撕除後 裝上機器底部 安裝步驟 壁掛式 11 接上鋁管 使用膠帶密封周圍 13 插上電源後測試所有功能是否正常運作 14 測試完成後開啟照明 喚醒導流板 當導流板 開啟後 請拿下濾網並撕除保護膜後裝回 9 再用 2 1 1 2 木螺釘將機器鎖固於牆面 ...

Page 36: ...c com 1 將風管吊掛片與機器中心對齊 並使用 2 1 1 2 木螺釘將吊掛片鎖於牆面 安裝步驟 選配風管飾板 選配飾風管飾版組 22 1 16 43 3 4 型號 P1C 0068 注意 P1C 0068不包含在機器裡面 請上我們網站www 2pacific com 或撥打 888 833 8833 訂購此產品 Min Max P1C 0068 風管飾板組 www pacifichoods com 718 633 3688 ...

Page 37: ...安裝步驟 選配式風管飾版 12 www 2pacific com 2 將附件包內兩支固定片各使用 6 M4x8黑色螺絲鎖固於機器頂部 4 使用 2 M4x8圓頭螺絲將內風管飾板鎖固於吊掛片上 並用 2 M4x8圓頭螺絲 將外風管飾版固定在底部固定片上 3 移除風管飾板表面保護膜 ...

Page 38: ...4 3 2 1 關閉 顯示框會顯示當時的速別 按下 鍵可提高風扇轉速 開啟 1 2 3 4 顯示框會顯示當時的速別 風速調整鍵 延遲關機鍵 計時鍵 有兩種時段可以選擇5分鐘或3分鐘 開機狀態下 按1下 啟動5分鐘延時關閉計時器 再按第2下則為3分鐘 且風速降至1速中間螢幕會 顯示剩餘時間 此功能開啟時可以依需求調整風速 時間到後會自動關閉風扇和照明 若想中途停止 可以按下 關閉電源即可停止倒計時 顯示速別 延遲關閉倒數 小時 分鐘 分鐘 小時 按壓 或 設定 分鐘數字從0到59循環 長按 或 時 中間的數字會快速跳動 若確定後按1下 即可 設定小時 按壓 或 設定時間 數字從0到99循環 若確定後 按1下 即設定完成 在未使用延遲關機功能或設定時鐘的狀態下 按1下 進入設定 設定中連續6秒未操作機器則不會儲存 當前設定會自動離開設定介面 計時途中 可切換風速 按1下 就會停止計時 電源鍵 ...

Page 39: ...間設定 設定過程中若連續6秒以上未動作 將不會儲存當前設定並自動離開設定介面 設定時鐘時 機器會強制取消計時器動作 按壓 或 設定 分鐘數字從0到59循環 長按 或 時 中間的數字會快速跳動 若確定後按1下 即可設定小時 按壓 或 設定 分鐘數字從1到12循環 長按 或 時 中間的數字會快速跳動 若確定後按1下 即可設定小時 分鐘 小時 關機狀態下 同時按住 和 3秒 會顯示原廠設定為6 按一下 進入設定 每按1下 介面數字會顯示6 4 3 6循環 超過6秒沒有動作 機器會不儲存並自動離開設定介面 當螢幕顯示為 6 則目前風速為原廠設定 當螢幕顯示為 4 則目前設定最大為400CFM 當螢幕顯示為 3 則目前設定最大為300CFM ...

Page 40: ...過濾網拆下清洗 3 過濾網可用溫水清洗或請使用非腐蝕性洗碗精浸泡後清洗 風乾後請安裝回機身 4 若過濾網有所損壞 請洽經銷商購買更換 5 移除過濾網方法如右圖示 1 握住濾網把手將濾網向下壓 2 將濾網前端向外取出 3 將濾網從機器上取下 三 排油煙機清潔方法 1 清潔排油煙機時 請先拔掉電源插頭以免發生危險 2 請勿用水沖洗馬達以免馬達燒毀 3 煮食時 勿噴清潔劑清洗排油煙機 以免清潔劑掉落菜餚 4 清潔時 藉由工具拆卸零件 使用者不得徒手拆卸 以免發生危險 5 建議市售之廚房專用除油清潔劑 依據市售之廚房專用除油清潔劑 使用方法清潔 排油煙機煙罩外殼表面 6 清潔油杯 將油杯往自身方向拆下 在油杯中倒入除油清潔劑 靜置30分鐘再清洗 產品保養與清潔 使用者依煮食習慣一周清潔一次 當油杯油污七分滿時 請清潔油杯 請勿直接噴灑清潔劑至開關表面 15 www 2pacific com ...

Page 41: ...電線是否正確連接 馬達熱保護裝置溫度下降後機器將恢復正常運作 檢查風管是否正確密封 風管未密封或正確安裝 更換開關組或主控PC板 更換馬達 更換開關組或主控PC板 檢查連接到馬達的所有連接線是否都正確連接 更換風葉 將馬達鎖緊 LED燈連接線脫落 LED燈損壞 更換LED燈 檢查LED燈連接線是否正確連接 出風口或排風管阻塞 移除出風口或排風管的阻塞物 開關組或主控PC板損壞 更換開關組或主控PC板 出風口尺寸不正確 機器的安裝高度過高 窗戶或門開啟導致風進入影響機器排風 關上門窗防止風影響機器排風 調整機器底部至爐面的距離 建議安裝距離為 15 20 1 2 改為正確出風口尺寸 機器未正確安裝 濾網或導流板未正確安裝 檢查機器是否正確安裝 調整濾網或導流板直到口哨聲消失 檢查連接到主控PC板的所有連接線是否都正確連接 馬達正常運作 但LED燈不動作 馬達損壞 出風口或排風管阻塞 更換馬達...

Page 42: ...www 2pacific com ...

Page 43: ...www 2pacific com ...

Page 44: ...油煙機 https www 2pacific com en us productregistration PACIFIC KITCHEN LIFE 390 Kansas St San Francisco CA 94103 888 833 8833 即時註冊的幫助不止一種 註冊很重要 當您需要服務時 確保產品保固範圍 保障產品所有權驗證 產品變更或召回通知 如需要訂購零件 請上 www 2pacific com 跟我們聯繫或者以電話 888 833 8833聯絡我們 www pacifichoods com 718 633 3688 ...

Reviews: