INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference

DANGER - IF YOU SMELL GAS

1. Shut off gas to the appliance. 

2. Extinguish any open flame. 

3. If odor continues, keep away from the appliance and immediately call your gas   

    supplier or fire department.

WARNING

Do not store or use gasoline or other flammable vapors and liquids in the vicinity 

of this or any other appliance.  An LP-cyllinder not connected for use shall not be 

stored in the vicinity of this or any other appliance.

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide which has no odor. 

Using it in an enclosed space can kill you. 

Never use this appliance in an enclosed space such as a camper, tent, 

car or home.

WARNING:

Improper installation, adjustment, alteration, service or maintenance can cause 

injury or property damage. Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this equipment.

WARNING: FOR OUTDOOR USE ONLY!

DANGER

OUTDOOR FIREPIT BURNER MODELS LIN-48, LIN-48P or LIN-36, LIN-36P

ROBATA 72 & 54 CORTEN FIRE |

 

Installation Manual

Burner conforms to:  ANSI Z21.97/CSA 2.41 - (2012/10/01) “Outdoor Decorative Gas Appliances”

We recommend that our fire pits be 

installed and serviced by professionals 

that are certified in the U.S. by NFI 

(National Fireplace Institute)

Summary of Contents for ROBATA 72 CORTEN FIRE

Page 1: ...duce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING F...

Page 2: ... cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition 6 Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance 7 Young children should be carefully supervised when they are in the area of the appliance 8 This app...

Page 3: ...not be compromised FIG 1 BASE DIAGRAMS See page 12 of this manual for Gas Installation Requirements This appliance requires 110V AC power supply in the form of an outdoor receptacle installed inside the unit body ATTENTION Gas and electrical lines must be installed by licensed contractors in compliance with local codes Main power must be off when connecting to main electrical power supply or perfo...

Page 4: ...receptacle fire pit vessel should be placed so that the stubs are enclosed within the Robata Body 1 but do not interfere with the centre 8 of the unit see page 3 8 If the Robata Body 1 does not sit flat shim appropriately so that it is well and evenly supported 9 Connect Gas and Electrical as per page 7 10 Check for leaks test burner and complete installation as per pages 7 8 CAUTION HEAVY Use car...

Page 5: ...NENTS FIG 2 ROBATA CORTEN EXPLODED VIEW 72 MODEL SHOWN 2 Media Tray Suggested location for gas and electrical RECOMMENDED Outdoor receptacle with weatherproof in use cover 3 Burner Assembly LIN 36 48 4 Corten Cover 5 Gas Connection 6 Power Connection 24 VAC 1 Body ...

Page 6: ...6 ROBATA 72 54 CORTEN FIRE Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 8 8 72 ...

Page 7: ...ll prevent excess sealant from going into pipe Excess sealant in pipe could result in a clogged burner injector Install sediment trap in supply line as shown below Locate sediment trap where it is within reach for cleaning and trapped matter is not likely to freeze A sediment trap prevents moisture and contaminants from entering the Outdoor Fire Pit controls If a sediment trap is not installed or ...

Page 8: ...5 8 Place and evenly distribute decorative topping media lava rock or tempered glass pebble on top of burner media Completely fill topping receptacle Decorative media can be brought level with the top of the pilot cover Do not obstruct PILOT IGNITION PORT WARNING Failure to position parts in accordance with these diagrams and instructions and or failure to use parts specifically approved for use w...

Page 9: ...vers a fabric all weather cover and a stainless steel insert which converts your fire pit into a table when not in use To ensure that stainless steel insert seats properly decorative toppings must be arranged below the level of the stainless steel top See Fig 4 FIG 4 SECTION DIAGRAM STAINLESS STEEL COVER Top Burner Media Crushed Glass for NG Lava Rock for LP Decorative Media Must be kept below thi...

Page 10: ...ied service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or maintenance can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable...

Page 11: ... the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ignite burner turn on electric power to the appliance 11 To turn off appliance turn off electric power to the appliance TURNING OFF THE GAS TO THE APPLIANCE 1 Turn off all electric power supplied to the appliance if servi...

Page 12: ... PORT SIZE LIN 36 60 000 4 5 W C 10 5 W C 3 5 W C 26 35 1 8 LIN 48 80 000 4 5 W C 10 5 W C 3 5 W C 18 47 1 8 LIN 36P 57 000 11 0 W C 13 0 W C 10 0 W C 43 35 1 8 LIN 48P 77 000 11 0 W C 13 0 W C 10 0 W C 37 47 1 8 ELECTRICAL ALL MODELS 120V 15A OUTDOOR RECEPTACLE DEDICATED CIRCUIT WITH WALL SWITCH BURNER CONNECTS VIA AN AC ADAPTER MUST BE INSTALLED AND GROUNDED IN ACCORDANCE WITH LOCAL CODES ABOVE ...

Page 13: ...nings are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner If it evident that the burner is damaged the burner must be replaced prior to the appliance being put into operation PILOT FLAME The flames from the pilot should be visually checked as soon as the unit is installed and periodically during normal operation Th...

Page 14: ...BLOCK IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled Unit is smoking sooting excessively Note It is natural and unavoidable for appliance sets to produce moderate levels of carbon soot where flames contact the media 1 Poor fuel quality 2 Excessive flame impingement or blockage 3 Improper fuel air mixture 1...

Page 15: ...s loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 9 or replace pilot assembly 4 Check reconnect lead Burner does not light after pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 3 Burner orifice diameter is too small 4 Flame sensor lead loose disconnected 5 Main valve lead...

Page 16: ...5 Straight Burner w Venturi Throat Plate Set two pieces Burner Tray Chassis Control Box c w Cover Pilot Assembly Pilot Shroud Pilot Cover 3 8 MPT x 3 8 MPT Orifice Main Gas Valve Ignition Control Board Wire Harness Main Flex Connector Adapter 24 VAC 750 mA not shown Burner Media Topping Media 1 1 1 1 1 1 1 1 1 1 1 1 1 PKG PKG PKG LB14V072 LB14001 LB14072 CBLIN NA410 EPCLIN01 EPCLIN02 OAM004 GVBGD2...

Page 17: ...17 ROBATA 72 54 CORTEN FIRE Owner and Installation Manual ILLUSTRATED PARTS LIST cont d 1 7 2 5 6 9 10 11 3 8 ...

Page 18: ...LUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT NA410 OR LP410 IGNITION CONTROL BOARD CC 9120 30 GAS VALVE GVBGD258 ...

Page 19: ...s The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transpor...

Reviews: