background image

M8-HT-PRO

INSTRUCTIONS - 

English

M8-HT-PRO

INSTRUCCIONES - 

Español

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOL

TAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

Instalación (CA): 

1.

Apague todo el equipo que va a ser

conectado a la unidad. 

2.

Asegúrese que el protector esté apagado

y que esté en la posición OFF (vea el dibu-

jo).  Enchufe la unidad al enchufe en la

pared y encienda. 

3. Unsafe Voltage (voltaje peligroso)

(rojo) normalmente OFF; cuando está encen-

dida, es una luz intermitente que indica que

el voltaje es inseguro y que el protector ha

desconectado su equipo conectado.

4. DC Trigger (disparador de corriente

continuo)

– (verde) el status ON/OFF

depende de si una señal 12VDC está siendo

recibida de otro componente. 

ON

= La señal de voltaje de corriente contin-

ua (DC) está siendo recibida y los enchufes

de alta corriente están encendidos; 

OFF 

= No hay señal de un componente y los

enchufes de alta corriente están apagados. 

El M8-HT-PRO ha sido diseñada, teniendo en

mente, flexibilidad y expansión.  Esto modelo

acepta módulos de protección de línea de

señal adicionales en el evento que su insta-

lación tenga más líneas de señales que nece-

siten protección con una de la unidades

nombradas.  Más información está a su dis-

posición en nuestro sitio web (www.pana-

max.com) o de nuestro departamento de

cuidado del cliente (800-472-5555; 7:30 am-

4:30 PM tiempo pacífico).

Si tiene alguna pregunta sobre cual protector

es el mejor para su equipo, favor de ir a nue-

stro sitio web (www.panamax.com) o pón-

gase en contacto con nuestro departamento

de cuidado del cliente. 

Conectando su protector contra

sobrecargas de tensión correcta-

mente 

Para proteger su equipo completamente de

sobrecargas, cada alambre que sale o entra

del equipo que usted quiere proteger debe

ser conectado al protector de sobrecargas de

tensión indicado.  Relámpagos dañinos y

sobrecargas de tensión pueden entrar a su

sistema por cualquier línea de señal (línea

telefónica, alambres de tierra, cables coaxi-

ales, cables modem, cables red de área local

(LAN), etc.) o corriente alterna que estén

conectados a su equipo electrónico. 

Puntos importantes de seguridad 

Los protectores contra sobrecargas de ten-

sión y el equipo conectado deben estar

adentro en un local seco y en el mismo edi-

ficio.  Aunque su protector Panamax es

duradero, sus componentes internos no

están aislados del ambiente.  No instale

ningún producto de Panamax cerca de

aparatos que emitan calor tal como un radi-

ador o contador térmico.  No instale este

producto donde haya humedad excessiva tal

como una tina, fregadero, piscina, en el piso

de un sótano, pescera, etc.  

Es común que un edificio no esté correcta-

mente conectado a tierra.  Para proteger su

equipo, los productos de Panamax deberán

ser directamente enchufados a un tomacor-

riente CA de 3-alambres con conexión a

tierra.   Adicionalmente, el alambrado del

edificio y conexión a tierra deberán confor-

marse a los códigos NEC (EEUU) o CEC

(Canada) para que la póliza de protección

de Panamax sea válida. 

No use adaptadores de 2-cuchillas o

cualquier otro “cintas de energía” con este

producto.  Sólo use cables de extensión de

Panamax si requiere un cable más largo. 

M8-HT-PRO –

Provee protección CA

(sobrecargas, subtensión y sobretensión),

protección coaxial (CATV, antena fuera de

aire o cable para modem) y protección de

línea de teléfono para aparatos electróni-

cos.  Además tiene un disparador de

entrada y dos bancos de (4 enchufes de

CA cada uno) de circuitos de filtración de

ruido.  El primero, es un circuito de fil-

tración capacitativa, es para componentes

de alta corriente tales como amplificadores

y subwoofers.  El otro es un filtro equili-

brador doble L para equipo con fuentes

A/V o aparatos de visualización. 

Ésto modelo tiene 8 enchufes CA que son

controladas por la combinación cortacir-

cuito/conmutador de electricidad.  Los 4

enchufes de alta corriente también pueden

ser controlados por una señal 12VDC de

otro componente. Este circuito continua-

mente monitorea la electricidad y protege

contra daño causado por la reducción de

tensión de línea y sobretensión continua.

Automáticamente desconecta la electricidad

a su equipo conectado cuando cualquiera

de estas condiciones es detectada, y

entonces lo reconecta cuando la electricidad

ha regresado a un nivel prudente. 

Esto modelo tiene 4 díodos emisores de luz

(LED) para seguridad máxima.  Están nom-

brados como sigue:

1. Power ON, Protection OK

– (verde)

normalmente ON; indica que el protector

está funcionando correctamente y que todo

el equipo conectado está protegido. 

2. Ground OK (tierra OK)

– (verde) nor-

malmente ON; indica que el tomacorriente de

la pared está correctamente alambrado y

puesto a tierra.

3.

Verifique que el LED verde “Ground OK”

esté prendido, esto indica que el enchufe en

la pared está correctamente alambrado y

puesto a tierra. 

4.

Enchufe el equipo que va a proteger a la

unidad Panamax y uno por uno, encienda

cada una de las piezas de equipo conecta-

do y vea si están operando correctamente. 

a.

Equipo Audio/Video tales como recep-

tores, lectores DVD, Televisores, etc, deben

ser enchufados a los tomacorrientes enu-

merados 1-4.  Este banco de tomacorri-

entes provee electricidad de un circuito de

filtración “equilibrador doble L” para que el

ruido de interferencia electromágnetica/

interferencia radioeléctrica (EMI/RFI) no

interfiera con su equipo de visualisación/

fuente. 

b.

Equipo de alta corriente tales como

amplificadores y altavoces deben ser ench-

ufados en los tomacorrientes ennumerados

5-8.  El banco de circuitos de filtros capac-

itativos (sin inductores) limpian la corriente

sin limitar el consumo de corriente a sus

amplificadores. 

LED Indicators

DC Trigger LED
Unsafe Voltage LED
Ground OK LED
Power ON/Protection OK LED

Phone Jacks

Includes Phone Cable (4 ft.)

and Cat 5 Cable (4 ft.)

ON/OFF Power Switch and

Circuit Breaker Combo

8 ft. AC Power Cord

Right Angle with 

45 Degree Offset Plug

8 AC Outlets

Outlets 1-4 feature 

“Balanced Double L” 

Filtration Circuit

Outlets 5-8 for high 

current equipment

Top and Bottom

Mounting Brackets

(Screws and Spacer

Eyelets included)

Telco and LAN Connector RJ-45 

Una nota para instaladores de ante-

nas de televisión, satélite, y cable:

Artículos 810.21 y 820.40 del código NEC

provee guías especifícas a como conectar a

tierra correctamente, y en particular, especi-

fica quel cable de tierra será conectado al

sistema de tierra del edificio, lo más cer-

cano a la entrada del cable que sea posible. 

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

DC Trigger

For high current

outlets (5-8)

La garantía de $5,000,000 de protección de

equipo conectado de Panamax es nula si

cualquier alambre entrando o saliendo del

equipo no está correctamente conectado al

protector(es) contra sobrecargas de tensión

indicado.  El protector contra sobrecargas de

tensión también debe ser enchufado a un

tomacorriente alambrado correctamente y

puesto a tierra. Favor de leer la garantía para

detalles o si tiene preguntas llame al depar-

tamento de atención del cliente de Panamax. 

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOL

TAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

INSTALLATION  (AC Power):

1.

Turn 

OFF

the  power  to  all  equipment

that will be plugged into the unit. 

2.

Make sure that the ON/OFF switch is in

the 

OFF

position (see figure).  Plug the unit

into the wall outlet and then turn it 

ON

.

3.  UNSAFE  VOLTAGE 

–(red)  normally

OFF;  flashes  when  lit,  indicates  that

incoming  voltages  are  unsafe  and  the

surge  protector  has  disconnected  the

power to your connected equipment.

4. DC Trigger  

–(green) ON/OFF status

depends  upon  whether  or  not  a  12VDC

signal  is  being  received  from    another

component when utilizing.  

ON

= DC voltage signal is being received

and high-current outlets are 

ON

;  

OFF

= No signal from source component

and power to high-current outlets is 

OFF

.

The  M8-HT-Pro  has  been  designed  with

flexibility  and  expansion  in  mind.    It  will

accept add-on signal-line protection mod-

ules in the event that your installation has

more  signal-lines  than  can  be  protected

with one unit.  More information is avail-

able  on  our  website  (www.panamax.com)

or from our Customer Support Department

(800-472-5555; 7:30AM – 4:30PM PST).

If you have any questions about which pro-

tector is best for your application, please

check our website (www.panamax.com) or

contact Panamax Customer Support. 

PROPERLY CONNECTING YOUR

SURGE PROTECTOR

To completely protect your equipment from

surges,  every  wire  leading  into  or  out  of

the equipment you want to protect must be

connected  to  the  appropriate  Panamax

surge protector.  Damaging lightning and

power  surges  can  enter  your  system

through  any  AC  power  or  signal-line

(phone line, grounding wires, coax cables,

modem cables, LAN cables, etc.) connect-

ed to your electronic equipment.

IMPORTANT SAFETY POINTS

Panamax  surge  protectors  and  the  con-

nected equipment must be indoors, in a

dry  location  and  in  the  same  building.

Although your Panamax protector is very

durable,  its  internal  components  are  not

isolated  from  the  environment.    Do  not

install  any  Panamax  product  near  heat

emitting appliances such as a radiator or

heat register.  Do not install this product

where excessive moisture is present; for

example near a bathtub, sink, pool, base-

ment floor, fish tank, etc.

It is not uncommon for a building to be

improperly grounded.  In order to protect

your equipment, Panamax products must

be  plugged  into  a  properly  wired  and

grounded  3-wire  outlet.    Additionally,

building wiring and grounding must con-

form  to  applicable  NEC  (USA)  or  CEC

(Canada) codes for the Panamax protec-

tion policy to be valid.

Do not use 2-blade adapters or any other

“power strips” with this product.  Use only

Panamax extension cords if a longer cord

is required.

M8-HT-PRO

–  Provides  AC  power

(surge,  under-voltage  and  over-voltage)

protection, coaxial (CATV, off-air antenna,

SAT or cable modem) protection and tele-

phone/LAN  line  protection  for  electronic

devices.  In addition, it features a 12VDC

input trigger and two banks (4 AC outlets

each) of noise filtration circuitry.  One, a

capacitive filter circuit, is for high-current

draw  components  like  powered  sub-

woofers or amplifiers.  The other is a bal-

anced  double  L  filter  for  A/V  source

equipment or display devices. 

This  model  features  Panamax's  patent-

pending  Automatic  Voltage  Monitoring

(AVM) circuitry for over and under voltage

protection.  This  circuitry  continuously

monitors the power and protects against

damage  caused  by  brownouts  (under-

voltages) and sustained over-voltages. It

automatically  disconnects  the  power  to

your connected equipment when either of

these  conditions  are  detected,  then  re-

connects  it  when  the  power  returns  to  a

safe level.

The  M8-HT-PRO's  coaxial  protection  cir-

cuits achieve optimum signal quality from

our  new  coaxial  protectors  that  have  the

smallest  signal  loss  on  the  market  -  less

than 0.5dB of attenuation from 5MHz to 2

GHz. Our upgraded coaxial protection has

been specifically designed to virtually elim-

inate signal loss. The clamping level of 75V

will  meet  the  demands  of  both  cable  and

satellite voltage while minimizing exposure

to damaging spikes and surges.

This model has 4 diagnostic LEDs for max-

imum  safety.  They  are  designated  as  fol-

lows:

1.  POWER  ON,  PROTECTION  OK

(green)  normally  ON;  indicates  that  the

surge protector is functioning properly and

that all connected equipment is protected.

2.  GROUND  OK

–(green)  normally  ON;

indicates  that  the  wall  outlet  is  properly

wired and grounded.

3.

Verify that the green “Ground OK” LED

is lit, indicating that the wall outlet is prop-

erly wired and grounded.

4

. Plug the equipment to be protected into

the Panamax unit and one at a time, turn

each piece of connected equipment ON and

check for correct operation.

a.

Audio/Video equipment like receivers,

DVD players, TVs, etc. should be plugged

into the outlets numbered 

1-4

.  This bank

of  outlets  provides  power  from  a

“Balanced  Double  L”  filtration  circuit  so

that  EMI/RFI  noise  is  prevented  from

reaching your source/display equipment.

b. 

High-current equipment like amplifiers

and  powered  subwoofers  should  be

plugged  into  the  outlets  numbered

5-8

.

This bank’s capacitive (inductor-less) filter

circuit  cleans  the  power  without  limiting

current flow to your amplifiers.

LED Indicators

DC Trigger LED
Unsafe Voltage LED
Ground OK LED
Power ON/Protection OK LED

Phone Jacks

Coax Connectors

Includes Phone Cable (4 ft.)

and Cat 5 Cable (4 ft.)

ON/OFF Power Switch and

Circuit Breaker Combo

8 ft. AC Power Cord

Right Angle with 

45 Degree Offset Plug

8 AC Outlets

Outlets 1-4 feature 

“Balanced Double L” 

Filtration Circuit

Outlets 5-8 for high 

current equipment

Top and Bottom

Mounting Brackets

(Screws and Spacer

Eyelets included)

3 sets of IN /OUT, bidirectional,

universal coax connectors

3 RG-6 Coax Cables

Coax Connectors

3 sets of IN /OUT, bidirectional,

universal coax connectors

3 RG-6 Coax Cables

Telco and LAN Connector RJ-45 

NOTE to TV ANTENNA, SATELLITE

DISH and CATV INSTALLERS:

Articles  810.21  and  820.40  of  the  NEC

provide  specific  guidelines  for  proper

grounding, and in particular, specify that

the  cable  ground  shall  be  connected  to

the grounding system of the building, as

close to the point of cable entry as prac-

tical.

  POWER ON

PROTECTION OK

GROUND OK

UNSAFE VOLTAGE

DC TRIGGER

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

DC Trigger

For high current

outlets (5-8)

The  Panamax  $5,000,000  Connected

Equipment Protection Policy is void if any

wire leading into or out of the equipment

is not properly connected to the appropri-

ate  Panamax  surge  protector(s).    The

surge protector must also be plugged into

a  properly  wired  and  grounded  outlet.

Please see the warranty for details or con-

tact  the  Panamax  Customer  Support

Department with questions.

5.

Turn 

OFF

the  unit  and  all  connected

equipment before connecting any signal-

lines or installing any add-on signal line

modules.

UNS

DC TRIG

GE

R

PO

W

ER

VO

LTA

GE

 TR

IGG

ER

INSTALLATION  (Telephone or LAN

Lines):

IMPORTANT:

Note  the  position  of  the

LINE

and 

EQUIP

jacks on the Panamax

unit.  

LINE 

is for the line connection that

comes from the wall or floor jack. 

EQUIP

is for the line connection to your connect-

ed equipment.  The protection circuit will

only  function  if  connected  properly.

Reversed connections will pass the signal

to the connected equipment but will also

prevent  the  protection  circuitry  from

working and will invalidate the Panamax

Connected Equipment Protection Policy.

1.

Make sure the Panamax protector and

all connected equipment is turned 

OFF

.

2.

Take  the  incoming  telephone  or  LAN

line and plug it into the appropriate 

LINE

jack on the protector. The line should now

be  connected  between  the  wall  and  the

Panamax unit.

3.

Plug a telephone or LAN line into the

EQUIP

jack and then plug the other end

into the equipment to be protected.

4.

Turn 

ON

the protector and the connect-

ed equipment.  Verify that each piece of

connected equipment is receiving power

and signal.

The  M8-HT-PRO  provides  telephone  and

LAN protection on one set of RJ-45 (RJ-11

compatible)  jacks.    The  telephone  circuit

uses pins 4 & 5 while the LAN circuit uses

pins  1,  2,  3  &  6.    Adaptors  or  custom

cables (not included) must be used when

utilizing  both  protection  circuits  at  the

same time.

small rectangular bracket with a grounding

interface.  This bracket replaces the small

triangular  wall-mount  bracket  that  comes

with the AC base unit and is needed only

when add-on modules are being installed.

More information can be obtained on the

Panamax  website  or  by  calling  our

Customer Support Department.

ADDING SIGNAL-LINE MODULES

(Optional):

Some  connected  equipment  may  have

more signal-lines than can be protected by

the base unit alone.  Panamax offers a line

of add-on signal-line modules (sold sepa-

rately)  for  these  situations.  Each  module

includes installation instructions  and  a 

WALL MOUNTING (optional):

The  small  triangular  bracket  with  one

"key-hole" is for the top end of the unit.

This bracket mounts directly to the back

of  the  unit  with  the  #8-32  x  5/16”

machine screws, then to the wall with one

of the #6-20 x 3/4” pan-head screws and

spacer eyelets (drywall anchors optional).

The  large  rectangular  bracket  with  two

"key-holes"  is  for  the  bottom,  line-cord

end of the unit.  It mounts directly to the

unit with the thread-forming screws, then

to the wall with the other two #6 pan-head

screws  and  spacer  eyelets  (drywall

anchors optional).

Mounting procedure:

1.

Mount  both  brackets  to  the  unit  with

the appropriate screws.

2.

Determine  the  mounting  location  on

the wall and mark the position for the top

mounting screw.

3.

Place a spacer eyelet  on one of the #6

pan-head screws with the flared end of the

eyelet toward the wall. Drive the screw into

the wall (use the included drywall anchors

for  hollow  walls)  at  the  marked  location,

leaving the eyelet exposed.

4.

Position the key-hole on the unit's top

mounting  bracket  over  the  eyelet/screw

and slide the unit down to lock the screw-

head into the bracket.

5.

Mark  the  location  for  the  two  lower

mounting screws (in the narrow portion of

the  key-holes)  and  drive  the  screws  into

the wall using the other 2 spacer eyelets

like  in  step  #3.    The  included  drywall

anchors should be used for mounting on

hollow walls.

6.

Position the protector over the 3 eye-

lets/screws and slide the unit down to lock

it into place.

7.

Using the above procedure allows easy

removal of the unit by sliding the unit up to

disengage  the  brackets  from  the

eyelets/screws.

INSTALLATION (Coaxial Lines):

TROUBLESHOOTING– 

If you are having problems with your surge

protector, read this section.

The  “Power  On/Protection  OK”  LED

is not lit, there is no AC power to my

equipment,  or  my  equipment  does-

n’t turn on.

• 

Make sure that the protector is plugged

into a working AC outlet.

• 

Check all AC power connections.

• 

Make  sure  that  the  protector  and  con-

nected equipment are turned on.

• 

If using the DC Trigger input, verify that

the  source  equipment  is  providing  the

proper DC voltage signal.

• 

Verify that the “Unsafe Voltage” LED is

not lit. If it is on, the incoming line voltage

is either too high or too low and has been

disconnected from  your connected equip-

ment. 

• 

Check to see if the circuit breaker on the

surge  protector  (combination  power

switch/circuit  breaker) needs to be reset

(press “ON” to reset).

• 

If you still have no power, the protector

may be damaged.  Contact Panamax (web-

site or Customer Support Department) for

replacement.

There is no audio or video for my TV,

stereo or VCR.

• 

Check  the  coaxial  connections,  making

sure  they  are  correctly  and  securely

installed.

• 

Bypass the coaxial connectors.  If your

picture returns, the protector is damaged.

Contact  Panamax  (website  or  Customer

Support Department) for replacement. 

• 

If  you  still  have  no  picture,  a  problem

with your cable provider’s signal may exist.

My  fax  machine,  modem  or  tele-

phone  has  AC  power  but  still  does

not work.

• 

Check  to  see  if  your  connected  equip-

ment is receiving a dial tone.

• 

If not, bypass the surge protector’s phone

jacks to see if the protector is damaged.

• 

If your dial tone returns, the protector is

damaged.  Contact  Panamax  (website  or

Customer  Support  Department)  for

replacement.

• 

If you still have no dial tone, a problem

with the phone company’s lines may exist.

The  Panamax  circuit  breaker  dis-

connects  AC  power  from  the  con-

nected equipment.

• 

You have exceeded the ampere rating for

your  surge protector.  As a temporary fix,

disconnect  one or more pieces of equip-

ment.  Ask  your  Panamax  dealer  about

additional Panamax protectors that may be

required.

1.

Make sure the Panamax protector and

all connected equipment is turned 

OFF

.

2.

Connect  the  coaxial  cable  from  the

CATV system, antenna or Satellite dish to

the  appropriate 

LINE

connector  on  the

Panamax protector.

3.

Connect  a  coaxial  cable  from  the

EQUIP

jack on the protector to appropriate

input  jack  on  your  TV,  VCR,  Satellite

receiver or cable modem.

4.

Repeat  steps  2  &  3  for  all  additional

coaxial lines.

Coaxial connectors are bi-directional. You

may  install  your  equipment  into  either

jack.  When used with diplexers, this pro-

tection circuit must be placed between the

diplexer  and  the  Satellite  receiver;  it  will

not

protect the diplexer.

LINE 

(in)

EQUIP 

(out)

SAT/CATV 

(in)

EQUIP 

(out)

SAT/CATV 

(in)

EQUIP 

(out)

SAT/CATV 

(in)

EQUIP 

(out)

800-472-5555

www.panamax.com

INS00825 REV. A             2/07

RJ-45

1  2  3  4  5  6  7  8

LAN

TEL

INSTALLATION & OPERATION OF DC

TRIGGER (optional):

The  DC  Trigger  input  uses  a  standard

3.5mm (1/8”) mono jack.  The circuitry is

bidirectional regarding signal polarity so it

doesn’t  matter  whether  the  center-pin  of

the plug is positive or negative.  Connect a

standard 2-wire cable with a 3.5mm mini-

plug  from  your  source  component’s  DC

Trigger output (or appropriate AC Adapter

plugged  into  a  switched  outlet  on  your

receiver) to this jack.  The 4 high-current

outlets turn 

ON

when a DC voltage signal

is received from your source component.

Power  to  these  4  outlets  is  turned 

OFF

when  a  DC  voltage  signal  is  not  being

received.

Please note:

Power to the high-current

outlets will be controlled by the combina-

tion power switch/circuit breaker if noth-

ing is plugged into the DC Trigger jack. 

1

2

3

3

2

1

Reviews: