background image

Studio  Card

AW-PB301/PB305

Before attempting to connect or operate this product,

please read these instructions completely.

Summary of Contents for AW-PB301

Page 1: ...Studio Card AW PB301 PB305 Before attempting to connect or operate this product please read these instructions completely ...

Page 2: ...NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE The lightning flash with arrowhead sym bol within an equilateral triangle is intended to alert the user to the pres ence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilat eral triangle is intended to alert the user...

Page 3: ...PREFACE 2 SPECIAL NOTES ON OPERATION 2 PRECAUTIONS 3 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS 4 MOUNTING 5 CONNECTING A STUDIO SYSTEM 7 MENU ITEM SETTING 8 APPEARANCE 12 SPECIFICATIONS 13 STANDARD ACCESORIES 13 ...

Page 4: ...Y C signals will be output SPECIAL NOTES ON OPERATION Power Off Before Connecting or Disconnecting Cables Before plugging or unplugging the cables be sure to switch power off Handle Carefully Do not drop the product or subject it to strong shock or vibration This is important to prevent trou ble Avoid Humidity and Dust Avoid using the product at a humid dusty place because much humidity and dust w...

Page 5: ... shock do not remove screws or cov ers There are no user serviceable parts inside Do not let water metal or other foreign objects inside This is important to prevent fire and electric shock If you see smoke or smell an odor from the product if water or other foreign matter gets inside if it is damaged by dropping or if you find anything wrong with it immediately stop using it 3 ...

Page 6: ...in standby condition The position ON the picture is shown in the view finder screen e Intercom volume control LEVEL Used to adjust intercom volume level r Intercom connector INCOM Connect an intercom to this connector If the intercom plug has a different diameter use the conversion adapter supplied as an accessory LEVEL INCOM EVF ST BY ON Viewfinder connector Viewfinder standby switch Intercom vol...

Page 7: ...off and disconnect the power connector and other cables from the camera 2 Loosen the four screws on the rear of the camera and remove the rear panel 3 Loosen the two screws for the option card slot and remove the cover 4 Insert the Studio card along the guide rail at the bottom of the camera and the tab above Insert it securely all the way 5 Tighten the two card setscrews securely If you have lost...

Page 8: ... 6 Panasonic Panasonic Option card slot cover Studio card Card setscrews 6 mm Rear Panel Rear panel setscrews 8 mm ...

Page 9: ...UDIO SEE MANUAL VIDEO 1 G Y Y VIDEO 2 B PB B SYNC S VIDEO 1 4 2 3 TALLY CAMERA MULTI CABLE SELECT FUSE 250V 1 25A TALK INCOM RECEIVE CONTROL TALLY INCOM MULTI OVP MPX MPX OUTPUT RCU cable AW CA50A26 15 m RCU WV RC700A AC120V 60Hz Cable selector switch Set it to MULTI Panasonic Viewfinder mounting bracket AW Q40 Push viewfinder from behind Turn clamp knob to fasten camera Turn clamp knob to fasten ...

Page 10: ...et Other Set Option Card Set Initialize Data End Main Menu of Halogen Fluorescent Outdoor Mode Main Menu of User Mode A convertible camera for example AW E300 can be set using the menu as suited to the system and shoot ing conditions For details refer to the operation manu al for the camera Setup Procedures Output Signal Selection 1 Display the main menu Camera alone Keep the menu switch depressed...

Page 11: ...h item switch or NO switch is pressed Select Option Card Set and press the YES switch to display the Option Card Set submenu 3 Select an item to set using the menu switch and item switch 4 Change the settings using the YES and NO switch es 5 Select Return with the menu switch and item switch and press the YES switch to return to the main menu 6 The camera is now back in shooting condition Camera a...

Page 12: ...shown in the viewfinder Note If CVBS is selected at Item EVF Output Y CVBS r the zebra indicator will not be shown w Zebra 1 Level Set Zebra 1 Level 70 to 109 Zebra 2 Level Set Zebra 2 Level 71 to 110 Zebra level 1 or 2 can be only when Zebra Indicator q is at ON The zebra indicator can be shown in two steps using two zebra patterns 2 Level shows a finer zebra pattern than 1 level 2 Level must be ...

Page 13: ...re output to the viewfinder CVBS Color signals are output to the viewfinder No zebra indicator will be shown t Component Output Select Component Output R G B Y Pr Pb Y C AW PB301 only Component output signals can be selected Component output signals are output from the inter face remote connector on the rear of the camera Note R G B output or Y Pr Pb output will be posi tive in reproduced image re...

Page 14: ... 12 APPEARANCE mm inch LEVEL INCOM EVF ST BY ON 70 2 3 4 21 5 27 32 96 3 3 4 91 2 3 4 5 3 16 ...

Page 15: ...ching AW PB301 only Adjusting functions Intercom voice output level adjusted on the panel Zebra level adjusted using the menu Source voltage 12 VDC supplied from camera Power consumption 3 8 W AW PB301 0 5 W AW PB305 Operating temperature 10 C to 45 C 14 F to 113 F Operating humidity 30 to 90 Dimensions 21 5 W x 70 H x 96 D mm 27 32 x 2 3 4 x 3 3 4 Weight 105 g Weight and dimensions indicated are ...

Page 16: ...ax 770 338 6741 Law Enforcement Video Products 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 Panazip 11 770 338 6844 fax 770 338 6721 WESTERN ZONE Seattle Region 1200 Westlake Ave North Suite 508 Seattle WA98109 206 285 8883 Los Angeles Region 6550 Katella Ave 17A 1 Cypress CA 90630 714 373 7271 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 PANASONIC CAN...

Reviews: