background image

CR

SPECIFICATIONS

TWIN POWER SILENT 

AUTOMOTIVE RELAY

CR RELAYS

18.5

.728

24.6

.969

17.0

.669

mm 

inch

RoHS Directive compatibility information

http://www.nais-e.com/

FEATURES

• Silent

Noise has been reduced by 
approximately 20 dB, using our own 
silencing design.

• Twin (1 Form C

 

×

 2)

Forward/reverse motor control is possible 
with a single relay.

• Sealed construction

• Simple footprint enable ease of PC 

board layout

Normally
Open

Common

Normally
Closed

Coil

Coil

Contact

Coil

#1 This value can change due to the switching frequency, environmental conditions, 

and desired reliability level, therefore it is recommended to check this with the 
actual load.

Characteristics

Arrangement

1 Form C 

×

 2

Contact material

Ag alloy (Cadmium free)

Initial contact resistance (Initial)
(By voltage drop 6 V DC 1A)

Typ. 6 m

 (N.O.)

Typ. 9 m

 (N.C.)

Contact voltage drop

Max. 0.2V (at 10 A)

Rating

Nominal switching 
capacity

N.O.: 20 A 14 V DC 
N.C.: 10 A 14 V DC

Max. carrying current

35 A for 2 minutes, 

25 A for 1 hour 

(12 V, at 20

°

C

68

°

F

30 A for 2 minutes, 

20 A for 1 hour 

(12 V, at 85

°

C

185

°

F

)

Min. switching capacity

#1

1 A 12 V DC

Expected life 
(min. operations)

Mechanical (at 120 cpm)

Min. 10

7

Electrical

Resistive load

Min. 10

5

*

1

Motor load

Min. 2

×

10

5

*

2

Min. 10

5

*

3

Nominal operating power

640 mW

Max. operating speed 
(at nominal switching capacity)

6 cpm

Initial insulation resistance*

4

Min. 100 M

 (at 500 V DC)

Initial breakdown 
voltage*

5

Between open 
contacts

500 Vrms for 1 min.

Between contacts 
and coil

500 Vrms for 1 min.

Operate time*

6

 

(at nominal voltage)(at 20

°

C

68

°

F

)

Max. 10 ms (initial)

Release time*

6

 

(at nominal voltage)(at 20

°

C

68

°

F

)

Max. 10 ms (initial)

Shock resistance

Functional*

7

Min. 100 m/s

2

 {10G}

Destructive*

8

Min. 1,000 m/s

2

 {100G}

Vibration resistance

Functional*

9

10 Hz to 100 Hz, 

Min. 44.1 m/s

2

 {4.5G}

Destructive*

10

10 Hz to 500 Hz, 

Min. 44.1 m/s

2

 {4.5G}

Conditions for 
operation, transport 
and storage*

11

 

(Not freezing and 
condensing at low 
temperature)

Ambient 
temperature

–40

°

C to +85

°

–40

°

F to +185

°

F

Humidity

5% R.H. to 85% R.H.

Mass

Approx. 12.5g

.44 oz

Remarks

*

1

At nominal switching capacity, operating frequency: 1s ON, 9s OFF

*

2

N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating 
frequency: 0.5s ON, 9.5s OFF

*

3

At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF

*

4

Measurement at same location as “Initial breakdown voltage” section

*

5

Detection current: 10mA

*

6

Excluding contact bounce time

*

7

Half-wave pulse of sine wave: 11ms; detection: 10

µ

s

*

8

Half-wave pulse of sine wave: 6ms

*

9

Detection time: 10

µ

s

*

10

Time of vibration for each direction;

X, Y, direction: 2 hours
Z direction: 4 hours

*

11

Refer to Conditions for operation, transport and storage mentioned in AMBIENT 
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere 
(110

°

230

°

F

).

X

Y

Z

TYPICAL APPLICATIONS

• Power windows
• Auto door lock
• Electrically powered sunroof
• Electrically powered mirror, etc.

ORDERING INFORMATION

Contact arrangement

Coil voltage(DC)

1 Form C 

×

 2

Standard packing: Carton(tube package) 32pcs. Case: 800pcs.

12 V

Ex. CR

2

12 V

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Summary of Contents for CR Relays

Page 1: ...een contacts and coil 500 Vrms for 1 min Operate time 6 at nominal voltage at 20 C68 F Max 10 ms initial Release time 6 at nominal voltage at 20 C68 F Max 10 ms initial Shock resistance Functional 7 Min 100 m s2 10G Destructive 8 Min 1 000 m s2 100G Vibration resistance Functional 9 10 Hz to 100 Hz Min 44 1 m s2 4 5G Destructive 10 10 Hz to 500 Hz Min 44 1 m s2 4 5G Conditions for operation transp...

Page 2: ...4 5 177 Pre soldering A Max 1 0 039 Dimension Tolerance Max 1mm 039 inch 0 1 004 1 to 3mm 039 to 118 inch 0 2 008 Min 3mm 118 inch 0 3 012 Dimensions thickness and width of terminal specified in this catalog is measured before pre soldering Intervals between terminals is measured at A surface level PC board pattern Bottom view Tolerance 0 1 004 Schematic Bottom view 4 5 177 4 5 177 4 5 177 3 5 138...

Page 3: ...mbient temperature C Ratio against the rated voltage V 10 20 30 70 60 50 40 80 40 20 20 40 60 100 0 Pick up voltage upper limit Pick up voltage lower limit 80 0 30 20 10 40 50 60 70 Voltage V Frequency n 1 5 2 0 2 5 3 0 3 5 4 5 5 0 4 0 5 5 6 0 6 5 7 0 7 5 Pick up voltage Drop out voltage 6 Distribution of operate time Sample CR2 12V 100pcs 7 Distribution of release time Sample CR2 12V 100pcs With ...

Page 4: ...de N C side Load current waveform Inrush current 25A Steady current 6A Brake current 15A Tested voltage 14V DC 100ms 10A 9 2 Electrical life test Motor lock Sample CR2 12V 3pcs Brake current 22A power window motor actual load lock condition Tested voltage 14V DC Switching frequency ON OFF 0 5s 9 5s Ambient temperature Room temperature Circuit Change of pick up and drop out voltage Change of contac...

Reviews: