background image

English

T

i

ế

ng V

i

t

Operating Instructions

Air Conditioner

Model No.
Indoor Unit

Outdoor Unit

CS-XZ9ZKH-8
CS-XZ12ZKH-8
CS-XZ18ZKH-8
CS-XZ24ZKH-8

CU-XZ9ZKH-8
CU-XZ12ZKH-8
CU-XZ18ZKH-8
CU-XZ24ZKH-8

H

ướ

ng d

n s

 d

ng

Máy 

đ

i

u hòa không khí

2-13

Tr

ướ

c khi b

t thi

ế

t b

, vui lòng 

đọ

c k

 h

ướ

ng d

n s

 d

ng này 

và gi

 l

để

 tham kh

o cho nh

ng l

n sau.

Tr

ướ

c khi l

đặ

t, ng

ườ

i l

đặ

t nên: 

Đọ

c h

ướ

ng d

n l

đặ

t và yêu c

u khách hàng c

t gi

 b

h

ướ

ng d

để

 tham kh

o sau này.

G

 

đ

i

u khi

n t

 xa 

đượ

đ

óng gói cùng v

i dàn l

nh.

Operating Instructions
Air Conditioner

14-25

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer 
keep them for future reference.
Remove the remote control packed with the indoor unit.

ACXF55-34510

Summary of Contents for CS-XZ9ZKH-8

Page 1: ...g l n sau Tr c khi l p t ng i l p t n n c h ng d n l p t v y u c u kh ch h ng c t gi b n h ng d n tham kh o sau n y G i u khi n t xa c ng g i c ng v i d n l nh Operating Instructions Air Conditioner 1...

Page 2: ...au nh n c i t th i gian Nh n n t CLOCK trong kho ng 5 gi y hi n th th i gian theo d ng 12 gi am pm ho c 24 gi 2 Nh n x c nh n A B M t Network Adaptor B i u h p m ng t ch h p s n cho ph p b n i u khi n...

Page 3: ...kho ng 10 gi y hi n th n v nhi t l C ho c F 2 Nh n ch n ch mong mu n COOL DRY AUTO iAUTO X HEAT M c L c C ch S d ng 4 6 T m Hi u Th m 7 8 V sinh M y i u h a 9 Nh ng v n th ng g p 10 13 Ph ki n i u kh...

Page 4: ...nh t c qu t h y h y ch iAUTO X QUIET Y N T NH Gi m ti ng n c a lu ng gi th i Ch n y k t h p gi a ch nanoe X v nanoe G nanoe TECHNOLOGY nanoe TECHNOLOGY b t u t ng khi thi t b c b t Nh n ON B T hay OFF...

Page 5: ...i u th i n v ti t ki m n ng l ng t t h n m kh ng nh h ng n s tho i m i Ch c n ng ECO kh ng th c k ch ho t khi ang s d ng ch iAUTO X Nh n n t l n n a h y b gi m l ng ti u th i n Ch c n ng n y s mang l...

Page 6: ...Nh n n t ho c ch n thi t l p ho c t ng ng sau nh n C i t h n gi g n nh t s c hi n th v s c k ch ho t sau Ch h n gi ho t ng theo c i t gi tr n i u khi n t xa v s l p l i h ng ng y khi gi h n c c i t c...

Page 7: ...nh o gi ngang c c nh v tr nh tr c C nh h ng gi d c s ch y theo h ng tr i ph i sau khi nhi t t ng l n ch COOL L M L NH C nh o gi ngang c c nh gi a v tr c i t Khi t c nhi t c nh o gi ngang s t ng xoay l...

Page 8: ...hi t b t t Kh ng t t ngu n i n trong khi th c hi n thao t c n y Thao t c v sinh b n trong ho n th nh khi qu t d ng v c nh o gi ng Khi c i n tr l i sau khi b l i ho t ng n y s kh ng ti p t c i u ki n h...

Page 9: ...khi m y ang ho t ng L i l c kh 2 tu n m t l n R a tr ng l i l c nh nh ng v i n c tr nh l m h b m t l i l c Ph i kh l i l c trong b ng r m tr nh xa l a ho c ph i tr c ti p d i n ng Thay l i l c khi b h...

Page 10: ...qu tr nh l m l nh kh ng kh l nh t a ra c th g y n c ng ng t Kh i ngo i tr i c n c ho c h i n c tho t ra ch l m l nh qu tr nh ng ng t x y ra t i c c ng ng l nh v n c ng ng t c th ch y t kh i ngo i tr...

Page 11: ...kh p ch a i u khi n t xa kh ng ho t ng n hi n th m ho c t n hi u y u Ki m tra pin c l p ng kh ng Thay pin y u M y kh ng ho t ng Ki m tra xem c u dao ng kh ng Ki m tra xem c h n gi t t kh ng M y kh ng...

Page 12: ...m b o kh ng c v t th l xung quanh c c ng gi v o v ng gi ra S d ng AUTO OFF ON T NG T T B T tr n m y ch n ch HEAT S I M COOL L M L NH Xem m c i u khi n t xa b m t ho c c l i x y ra tr n bi t th m chi...

Page 13: ...i nhi t s 2 c a kh i ngo i b t th ng H 33 Kh i trong kh i ngo i m t k t n i v i nhau H 34 C m bi n nhi t b l m m t kh i ngo i b t th ng H 35 N c ng ng ho c b m n c ng ng b t th ng H 36 C m bi n nhi t...

Page 14: ...he remote control receiver on the indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Pr...

Page 15: ...approximately 10 seconds to show the temperature as C or F 2 Press to select the desired mode COOL DRY AUTO iAUTO X HEAT Table of Contents How to Use 16 18 To Learn More 19 20 Cleaning the Air Conditi...

Page 16: ...er environment This operation combines both nanoe X and nanoe G nanoe TECHNOLOGY nanoe TECHNOLOGY automatically starts when the unit is turned on Press to turn ON or OFF this operation manually This o...

Page 17: ...iAUTO X mode To cancel iAUTO X mode press button Not applicable for Heat operation To reach the desired temperature quickly This operation provides you with a comfortable environment while sleeping I...

Page 18: ...n Press or to select the respective setting or then press The nearest timer setting is displayed and will activate in sequence The timer operation follows the clock setting on the remote control and w...

Page 19: ...n The vertical flap swings left right after the temperature rises In COOL mode The horizontal flap is fixed at middle position setting Once the temperature is achieved the horizontal flap swings up do...

Page 20: ...is turned off Do not turn off the power supply during this operation The inside cleaning operation is completed when the fan stops and the flap is close When power is resume after failure this operat...

Page 21: ...h during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Repl...

Page 22: ...peration Refrigerant flow inside the unit Mist emerges from indoor unit During cooling operation the discharged cold air may condense to water vapour Outdoor unit emits water or steam During cooling o...

Page 23: ...ntrol does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers h...

Page 24: ...n around the air inlets and outlet vents Use AUTO OFF ON on the unit to select HEAT COOL mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of op...

Page 25: ...Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H...

Page 26: ...Memo...

Page 27: ...Memo...

Page 28: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 34510 FZ1122 0...