Summary of Contents for GP-MF622E

Page 1: ...Machine Vision Camera GP MF622E Before attempting to connect or operate this product please read these instructions completely DEUTSCH FRAN AIS ENGLISH...

Page 2: ...SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The exclamation point within an equilateral triangle is intended to alert the user to...

Page 3: ...zioni della direttiva CEE 89 336 Wij verklaren als enige aansprakelijke dat het product waarop deze verklaring betrekking heeft voldoet aan de volgende normen of andere normatiefve dokumenten overeenk...

Page 4: ...age sensor with 752 H x 582 V pixels 2 Selectable scanning system 1 line interlace and 2 line interlace are avail able for the highest quality possible within video processing 3 External synchronizati...

Page 5: ...or other extremely bright objects Otherwise blooming or smear may be caused PRECAUTIONS 1 Do not attempt to dissemble the camera To prevent electric shock do not remove screws or covers There are no s...

Page 6: ...ed inside the camera turn the power off immediately and ask a quali fied service person for servicing 8 Do not operate the camera beyond the specified temperature humidity or power source ratings Use...

Page 7: ...HEIR FUNCTIONS 12P VIDEO 622 ON OFF 1 6 q 2 3 4 5 6 7 ON OFF 1 6 y u i o 0 1 e r w t 1 1 2 Manual Iris Lens Sold Separately 2 Camera Connector 12 pin This is connected with the optional Camera Cable G...

Page 8: ...S TO A DC 12V CLASS 2 POWER SUPPLY ONLY 5 Video Output Connector This connector is used to connect with the VIDEO IN connector of the monitor 6 Switch 1 No 1 1 ON 1 ON This switch selects the Field or...

Page 9: ...tch 1 Mode No 2 No 3 No 4 No 5 OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF ON ON OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF ON ON OFF ON ON ON OFF OFF OFF OFF ON ON OFF OFF ON OFF ON OFF ON Other Comb...

Page 10: ...Switch 2 No 6 to OFF 16 Switch 2 No 5 5 ON 5 ON This switch turns on or off the termination for HD signal with 75 17 Switch 2 No 6 6 ON 6 ON This switch turns on or off the termination for VD signal...

Page 11: ...an 300 g 0 66 lbs Note If the lens is heavier than 300 g 0 66 lbs both the lens and the camera should be secured by using the sup porter Mount C mount The protrusion at the rear of the lens should be...

Page 12: ...of this camera and the 12V DC Class 2 power supply not provided as an accessory 2 Connect the video connector of the GP CA34 to the Video Monitor OUT IN 75 Hi Z VIDEO 622 Camera GP CA34 Coaxial Cable...

Page 13: ...light such as a spotlight or a surface that reflects bright light smear or blooming may appear Therefore the camera should be operated carefully in the vicinity of extremely bright objects to avoid s...

Page 14: ...signal 4 0 V p p 75 negative supplied to EXT VD IN con nector can be used as reset signal Horizontal Resolution 560 lines at center Minimum Illumination 1 0 lx 0 1 foot candles F1 4 Manual Gain Max 6...

Page 15: ...ission Power Source DC 12 V 170 mA Ambient Temperature 10 C 50 C 14 F 122 F Dimensions 29 W x 29 H x 65 D mm 1 1 8 W x 1 1 8 H x 2 13 16 D Weight 86 g 0 19 lbs Camera Only Dimensions and weight indica...