WARNING
If you ignore the advice with this mark, death or serious injury could result.
CAUTION
If you ignore the advice with this mark, injury or material damage could re-
sult.
In this Instruction Manual, and are indicated de-
pending upon the level of danger. Please observe them strictly for the
safe use of this sensor.
WARNING
CAUTION
Hazard Indications
WARNING
٨
Installation of a touch bumper
You are requested to always install a touch bumper when this product is
used on an automatic guided vehicle (AGV).
CAUTION
٨
Use outside Japan
This sensor conforms to the EMC directive. However, it is not certified
by a competent body in accordance with other country safety standards.
Since each country has its regulations, please follow the local and na-
tional regulations of the country where this sensor is used.
CAUTION
٨
Fail-safe measures
This sensor is meant for proximity detection and does not possess con-
trol functions for safety maintenance.
If fail-safe measures are required, consider their incorporation in the to-
tal system.
Further, do not connect the sensor output directly to a stopping mecha-
nism (brake).
CAUTION
٨
Periodical maintenance check
The person incharge must periodically confirm the performance of the
product and maintain a record of such checks. In addition, whenever
the operating environment of the product is changed due to system
modification, etc., performance check must be done.
MOUNTING
2
٨
The tightening torque should be
1.2N
m or less.
M4 screw with washers
(Please arrange separately)
Main sensor mounting bracket
(
MS-PX-2
) (Accessory)
M4 (length 8mm)
screw with washers
<On main sensor mounting bracket (MS-PX-2)>
٨
Mount the sensor, horizontally, at least 300mm
above the floor, to avoid reflection from the floor.
300mm or more
Notes: 1)
2)
The sensing range is specified for white non-glossy paper (300
300mm).
Obtain the current consumption by the following calculation.
Current consumption = Power consumption
¸
Supply voltage
(e.g.) When the supply voltage is 12V, the current consumption (operating condition) is:
1.5W
¸
12V = 0.125A = 125mA
SPECIFICATIONS
1
Infrared LED (modulated)
Emitting element
0.3mm
2
5-core cabtyre
cable, 0.5m long
(for input and output)
For input and output:
0.18mm
2
9-core (
PX-24ES
and
PX-23ES
: 12-
core) cabtyre cable, 0.5m long
For auxiliary sensor connection:
0.18mm
2
10-core connector attached cabtyre
cable, 0.5m long
Cable
MS-PX-2
(Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
Matrix chart for sensing areas and external inputs 1 sheet (
PX-24ES
and
PX-23ES
only)
Accessories
170g approx.
210g approx.
220g approx.
210g approx.
Weight
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent
left OUT 1 and OUT 2 areas are adjusted independently.)
Sensitivity adjuster
Optical interference from up to 25 units is prevented.
Automatic interference
prevention function
IP65 (IEC)
Protection
-10 to +55
͠
(No dew condensation or icing allowed), Storage: -20 to +70
͠
Ambient temperature
35 to 85% RH, Storage: 35 to 85% RH
Ambient humidity
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
Material
Red LED (lights up when the beam is received in the effective OUT 1 areas)
OUT 1 area operation indicator
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
OUT 2 area operation indicator
Four sensing areas are selectable
with dip switches.
Four sensing areas are
selectable with dip
switches, and eight sens-
ing areas are selectable
with external inputs.
Sensing area
Fixed
Sensitivity of all areas (except auxiliary area
changes simultaneously in response to the
external analog voltage input (0 to +5V)
External sensitivity
adjustment input
㧙
Connected to 0 to +1V or GND (0V):
Auxiliary area ineffective
Connected to 4.5 to 31V, or open:
Auxiliary area effective
Right OUT 1 auxili-
ary area cancel input
Left OUT 1 auxiliary
area cancel input
㧙
80ms or less
Response time
㧙
㧙
Output operation
㧙
ON when modulated beam other than its own
(including auxiliary sensor's light is received
Short-circuit protection
NPN open-collector transistor
Maximum sink current: 100mA
Applied voltage: 40V DC or less
(between extraneous light monitor output and 0V)
Residual voltage: 1.5V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
Extraneous light
monitor output
Connected to 0 to +1V or GND (0V): Sleep condition
Connected to (supply voltage - 1V) to 31V, or open: Operational condition
Sleep input
㧙
Output operation
Incorporated
Selectable either Light-ON or Dark-ON with a switch (Output operation of
OUT 1 and OUT 2 is the same.)
Short-circuit protection
NPN open-collector transistor
Maximum sink current: 100mA
Applied voltage: 40V DC or less (between OUT 1 / OUT 2 and 0V)
Residual voltage: 1.5V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
OUT 1
OR circuit among the ef-
fective center, left, right,
adjacent left / right OUT
1 areas and the effective
auxiliary left / right areas
OUT 2
OR circuit among the
effective center, left,
and right OUT 2 areas
15% or less of operation distance
Hysteresis
Under operation: 1.5W or less, Under sleep condition: 0.3W or less
(without auxiliary sensor)
Power consumption
(Note 2)
10 to 31V DC including ripple
Supply voltage
3m
1m
3m
1m
5m
Sensing range (Note 1)
(OUT 1 and OUT 2 areas)
PX-22
PX-21
PX-24
PX-24ES
PX-23ES
PX-26
Type
Standard model
Short sensing range
Short sensing range
Long sensing
range
Auxiliary sensor connectable model
With external control function
Model No.
Item
Outputs
Inputs
Thank you very much for purchasing Panasonic products. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.
INSTRUCTION MANUAL
Obstacle Detection Sensor
PX-2
Series
MJE-PX2 No.0034-73V