background image

General Installation Manual 

 

HIT Photovoltaic Module

 

 

VBHN225DJ06 series

 

 

 
 
 
 
Thank  you  for  choosing  Panasonic  HIT 
photovoltaic (PV) modules. Please read 
this 

manual 

completely 

before 

installation or use of Panasonic

 

HIT PV 

modules.  With  proper  operation  and 
maintenance, 

Panasonic 

HIT 

PV 

modules  will  provide  you  with  clean, 
renewable  solar  electricity  for  many 
years.  This  manual  contains  important 
installation,  maintenance  and  safety 
information.  The  word  “module”  as 
used  in  this  manual  refers  to  one  or 
more  PV  modules.    Retain  this  manual 
for future reference.    
 
SANYO  is  part  of  the  Panasonic  Group 
and  is  in  charge  of  the  manufacturing 
process for Panasonic HIT PV modules. 
 
 
 
 
 
 
 
 

 

VBHN225DJ06 

 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 
Model No. 

 

VBHN225DJ06 

 

VBHN225DJ06B 

 
 
 

Contents 

 
Please read before installation 
Safety Precautions 

 

General Information 

:2 

 

Warning 

 

 

:2 

 

Cautions 

 

 

:2 

 

General Safety 

 

:2 

 
Installation 

 

General 

 

 

:2 

 

Notes on Installation 

:3 

 

 

Operating Conditions 

:3 

 

Special Conditions   

:3 

 
Specifications 

 

Note on Specifications 

:4 

 

Application Class of Product  :4 

 

Fire class of Product  

:4 

 

Mechanical Loading  

:4 

 

Certification 

 

 

:4 

 
Wiring 

 

General 

 

 

:4 

 

Module Wiring 

 

:4 

 

Array Wiring 

 

:4 

 

Earth Ground Wiring 

:4 

 

Module Terminations 

:4 

 

Junction Box and Terminals  :4 

 

Conduit 

 

 

:4 

 
Bypass Diodes 

 

 

:5 

 
Maintenance 

 

 

:5 

 
Disclaimer of Liability 

 

:5 

 
Customer Services  

 

:5 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VBHN225DJ06

Page 1: ...for future reference SANYO is part of the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT PV modules VBHN225DJ06 Model No VBHN225DJ06 VBHN225DJ06B Contents Please read before installation Safety Precautions General Information 2 Warning 2 Cautions 2 General Safety 2 Installation General 2 Notes on Installation 3 Operating Conditions 3 Special Conditions 3 Specificat...

Page 2: ...ctric shock injury or damage to the module Do not drop anything on the surfaces of a module to avoid the hazard of electric shock injury and damage To avoid the hazard of electric shock and fire be sure that all other system components are compatible and they do not subject the module to mechanical or electrical hazards Since sparks may occur do not install the module where flammable gases or vapo...

Page 3: ...be increased or decreased depending upon angles of installation height from surfaces shade from structures or rails and the albedo of surrounding surfaces The height of a module above a surface affects the power potential of the module s back face When it is possible maximize the height of modules above surfaces in order to maximize ambient light beneath the modules Always position support structu...

Page 4: ...s damage All modules connected in series should be of the same model number and or type Do not connect modules in parallel without using a connection box Do not disconnect terminals while modules generate electricity and connect electrical load to avoid the hazard of electrical shock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is...

Page 5: ...lity and expressly disclaims liability for loss damage or expense arising out of or in any way connected with installation operation use or maintenance by using this manual Panasonic assumes no responsibility for any infringement of patents or other rights of third parties which may result from use of modules No license is granted by implication or under any patent or patent rights The information...

Page 6: ...ectrical Specifications at Standard Test Conditions VBHN225DJ06 VBHN225DJ06B Cell Number in Series 72 Rated Power Watts Pmax W 225 Maximum Power Voltage Vpm V 43 2 Maximum Power Current Ipm A 5 21 Open Circuit Voltage Voc V 52 4 Short Circuit Current Isc A 5 54 Cell Type HIT Maximum System Voltage V 600 Maximum over current protection A 15 Factory Installed Bypass Diodes 6 HIT Heterojunction with ...

Reviews: