background image

-1-

Before attempting to connect or operate this product,

please read these instructions carefully and save this manual for future use.

Central Processing Unit

Model No.

WJ-MPU855

The serial number of this product may be found on the rear of
the unit.
You should note the serial number of this unit in the space
provided and retain this book as a permanent record of your
purchase to aid identification in the event of theft.

Model No.

Serial No.

WARNING:

To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.

The lightning flash with arrowhead sym-
bol, within an equilateral triangle, is
intended to alert the user to the pres-
ence of uninsulated "dangerous voltage"
within the product's enclosure that may
be of sufficient magnitude to constitute a
risk of electric shock to persons.

The exclamation point within an equilat-
eral triangle is intended to alert the user
to the presence of important operating
and maintenance (servicing) instructions
in the literature accompanying the appli-
ance.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

SA 1965

SA 1966

NOTE: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be
required to correct the interference at his own expense.

FCC Caution: To assure continued compliance, (example -
use only shielded interface cables when connecting to com-
puter or peripheral devices). Any changes or modifications
not expressly approved by the party responsible for compli-
ance could void the user’s authority to operate this equip-
ment.

For U.S.A

Preface

The WJ-MPU855 CPU is the Central Processing Unit for the System 850 Matrix Switcher.  The System 850 Matrix Switcher is
a CCTV surveillance system having multiple video inputs, multiple video outputs, and multiple control stations.  The WJ-
MPU855 is capable of controlling a maximum of 1 024 video input sources and a maximum of 256 video outputs, such as
monitors, with 64 system controllers.
The WJ-MPU855 is a high-performance Intel X86 processor based computer running the OS-9 real time operating system
allowing you to build up a redundant system of duplicate CPUs.

Summary of Contents for WJ-MPU855

Page 1: ...o comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 2: ... q w t r e Front View CAMERA CROSS POINT OSD This port is used to exchange control data between the cages through a hub OTHER Reserved for future use u Controller Ports SYSTEM CONTROLLER RS 485 These ports are provided for controlling the 850 System with the WV CU350 system controllers Up to 12 controllers can be connected i Peripheral Interface Ports PERIPHERAL INTERFACE RS 232C These ports are r...

Page 3: ...ack mounting screws Cautions The cooling fans inside the CPU are subject to wear and need to be replaced periodically Do not block the ventilation opening or slots on the cover to prevent the appliance from overheating Always keep the temperature in the rack within 50 C 122 F Secure the rear of the appliance to the rack by using the additional mounting brackets procured locally if the rack is subj...

Page 4: ...50 Katella Ave Cypress CA 90630 714 373 7840 Specifications Power Supply 120 V AC 60 Hz Power Consumption 90 W Controllable Cameras 1 024 cameras 8 card cages Cross Point Controllable Cages 1 024 x 256 32 card cages Controllable Monitors 256 2 card cages System Controller Ports Ethernet 10Base T 8 conductor modular jack x1 Maximum 64 controllers RS 485 6 conductor modular jack x12 Maximum 12 contr...

Reviews: