background image

Pin No.

Designation

-1-

Video Output Board

WV-PB5504AE

Before attempting to connect or operate this product, please read these instructions completely

PREFACE

The WV-PB5504AE Video Output Board is provided for expanding the video output capability of the
Matrix Switcher.

APPEARANCE

1.

Alarm Output/Reset Output Connector (ALARM OUT/RESET OUT)
External Timing Input Connector (EXT TIMING IN)
Recover Input Connector (RECOVER IN)

ALARM OUT:

When the Matrix Switcher receives an alarm from the WV-PB5564E Alarm Board

or camera site receivers WV-RC100, WV-RC150 or WV-RC170, the alarm output signal is
provided at this connector for the Time Lapse VTR. The active pin number of the alarm out-
put depends on the alarm mode set by the on-screen programme (Mode-1, Mode-2,
Mode-3).

RESET OUT:

When the Matrix Switcher resets the activated alarm, the alarm reset output sig-

nal, either Open Collector or pulse, is provided at this connector for the Time Lapse VTR.

EXT TIMING IN:

The camera switching interval (Sequential Dwell Time) can be synchronized

with the lapse mode set in the Time Lapse VTR.
EXT. TIMING IN 1 controls Monitor 1 output, EXT. TIMING IN 2 controls Monitor 2 output, etc.
Supply the camera switching pulse from the Time Lapse VTR to this connector. Minimum
duration for camera switching pulse needs to be more than one (1) second.

RECOVER IN:

This connector accepts the alarm recover signal from the Time Lapse VTR.

When handling this board, hold only by circuit board edges. Otherwise components on the
board may be damaged by static electricity.

Caution

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

ALARM OUT 1
RESET OUT 1
RECOVER IN 1
Ground
EXT TIMING IN 1
Ground
ALARM OUT 2
RESET OUT 2
RECOVER IN 2
Ground
EXT TIMING IN 2
(+5V DC)
ALARM OUT 3
RESET OUT 3
RECOVER IN 3
Ground
EXT TIMING IN 3
Ground
ALARM OUT 4
RESET OUT 4
RECOVER IN 4
Ground
EXT TIMING IN 4
Ground
Ground

OUT

   IN

OUT

   IN

OUT

   IN

OUT

   IN

MONITOR

ALARM OUT

RESET OUT

EXT TIMING IN

RECOVER  IN

OUTPUT

1

2

3

4

q

w

25

13

24
23
22
21
20
19
18
17
16
15
14

12

11
10

9

8

7
6

5

4

3
2

1

Summary of Contents for WV-PB5504AE

Page 1: ...e Time Lapse VTR EXT TIMING IN The camera switching interval Sequential Dwell Time can be synchronized with the lapse mode set in the Time Lapse VTR EXT TIMING IN 1 controls Monitor 1 output EXT TIMING IN 2 controls Monitor 2 output etc Supply the camera switching pulse from the Time Lapse VTR to this connector Minimum duration for camera switching pulse needs to be more than one 1 second RECOVER ...

Page 2: ...eo input from a VTR or system expansion to 128 camera input 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 OFF 1 2 3 4 5 6 7 8 1 4 5 8 9 12 13 16 1 4 5 8 9 12 13 16 MONITOR OUT NO SW1 SETTING Be careful when setting these switches as the swtches are not physically located on the board in numerical order Switch location from the top of the board going do...

Page 3: ...cal so the board can installed in any slot However it is recommended to install the board as shown below for an orderly installation Note CPU RS 232C TIME ADJUST IN COM PRINTER OUT IN VS VD VD OUT OFF 9V 5V 5V POWER ON 11A00001 OUT IN 1 OUT IN 2 OUT IN 3 OUT IN 4 MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN OUTPUT MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN MONITOR ALARM OUT RESET...

Page 4: ...utput 1 4 Pulse VTR 5VDC 500msec or Open collector output 16VDC 100mA max External Timing Input 1 4 Pulse 5V p p interval time more than one second Recover Input 1 4 Make Contact or Open collector Input Contact time more than 0 5 second Interval time more than two seconds Character Generator Camera ID 30 characters 15 x 2 lines Character Style White with Black Border Black with White Border Dimens...