background image

User's Manual

PRO-LCD

Series UPS

Para Systems, Inc.

1455 Lemay Dr.

Carrollton, TX 75007

Phone: 1-972-446-7363

Fax: 1-972-446-9011

Internet: minutemanups.com

UPS Sizing:  sizemyups.com

PN - 34000407 R2

Summary of Contents for PRO1100LCD

Page 1: ...User s Manual PRO LCD Series UPS Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000407 R2...

Page 2: ...Other trademarks are property of their respective owners 1 Introduction 2 2 Controls and Indicators 6 3 Installation 8 4 Operation 11 5 Troubleshooting 14 6 Replacing the Battery 15 7 Obtaining Servic...

Page 3: ...NG This Uninterruptible Power Supply contains potentially hazardous voltages Do not attempt to disassemble the UPS beyond the battery replacement procedure This UPS contains no user ser viceable parts...

Page 4: ...t has been tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Sub part J of Part 15 of FCC Rules and the Class B limits for radio noise...

Page 5: ...Displays the amount of Battery Capacity available in the AC and Battery mode 3 Load Capacity Bar Graph Displays the amount of load connected to the UPS in the AC and Battery mode 4 AC normal and Boost...

Page 6: ...r or excessive humidity or where the UPS is exposed to direct sunlight Select a location which will provide good air circulation for the UPS at all times Route power cords so they cannot be walked on...

Page 7: ...whenever the UPS is connected to anAC source and there is an acceptableAC voltage present 90 150VAC It is recommended that the UPS s batteries be charged for a minimum of 4 hours before use The UPS m...

Page 8: ...ger than the start up or user invoked test This every two week test will run for approximately fifteen seconds to measure the battery s capability to support the output load The start up and user invo...

Page 9: ...fore attempting to service the batteries Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges h...

Page 10: ...ith the UPS on the load will not be backed up To hot swap the batteries start with step number 6 1 Turn off the equipment that is plugged into the output of the UPS 2 Turn off the UPS 3 Unplug the UPS...

Page 11: ...hnician about obtaining a new set It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material A Include a letter with your name addres...

Page 12: ...ting Temperature 0 to 35 degrees C 32 to 95 degrees F at Operating Elevation 1501 to 3 000m 0 to 10 000 ft 17 6 lbs 8 0 Kgs 19 8 lbs 9 0 Kgs 5 17 7 21 English 120VAC 1100VA 770W Protection Waveform Ty...

Page 13: ...ys of purchase The warranty shall be void if a the equipment is damaged by the customer is improperly used is subjected to an adverse operating environment or is operated outside the limits of its ele...

Page 14: ...25 24 Notes Notes English English...

Reviews: