background image

Programming steps to the PARADOX MG5050 Control panel 
working in conjunction to RDC transmitters. 

Connecting the transmitter to the panel: 

Connect the R (RING) wire to the transmitter negative. Connect the T (TIP) wire to the transmitter CID 
connection. Power the transmitter directly from the battery. 

Entering programming: 

Press ENTER 0 0 0 0 (This is the default code) 

Programming the communicator: 

The keypad expects a 3-digit section number 

 

Press 800 

Programming of the communicator options 

 

 

 

Ensure 1, 2, 5, 6 is on 

 

 

 

1 is TLM trouble 

 

 

 

2 is TLM reporting 

 

 

 

5 is Tone dial 

 

 

 

6 is force dial 

 

Press 801 

Program reporting options 

Ensure 1 is off and 2 is on 

 

 

 

 off - Always report disarming 

 

 

 

 on - Zone restoral reports on zone closure 

 

Press 802 

Program reporting options 

 

 

 

Ensure 1 and 5 is on 

 

 

 

 on 

 Report Arm/disarm on MSTN 1 

 

 

 

 on 

 Report Alarms/restores on MSTN 1 

 

Press 803 

Program reporting options 

 

 

 

Ensure 1 is on  

 

 

 

 on 

 Report Tamper/restores on MSTN 1 

 

Press 804 

Program reporting options 

 

 

 

Ensure 1 is on 

 

 

 

 on 

 Special reporting on MSTN 1 

 

Press 838 

Closing delay to be 000 seconds 

 

Press 851 

Armed report delay (default is 5min) 

 

 

 

Set it to 001 for 1min 

 