REM3-EI07
REM3
Hand-Held 2-Way Remote Keypad
V1.0
Instructions
Introduction
The REM3 combines the flexibility of a keypad with the convenience
and mobility of a remote control. Its 15 buttons allow for a greater level
of interaction with the system than regular remote controls, and the two-
way transceiver allows for accurate feedback for up to 2 partitions.
Assigning the REM3 to the Panel
One-touch Arm Keys
The REM3 offers the use of one-touch arm keys. The use of one-touch
arm keys must be enabled in section
[703]
, options
[1]
to
[3]
in the
panel.
Technical Specifications
RF frequency
433MHz or 868MHz
Battery type
One 3V lithium battery (2032)
Battery life
Battery life expectancy is a minimum of 1 year.
“Low Battery Signal” is sent to the control panel when
battery is below 2.2Vdc. Upon power-up, a “Low
Battery Restore Signal” is sent to the control panel
when the battery voltage level has reached 2.7Vdc or
higher.
Range (typical in a
residential environment)
45m (150ft)
Compatibility
MG5000 / MG5050 V3.0 and higher /
Spectra SP Series V3.0 and higher in conjunction
with a RTX3 V1.31 and higher.
IMPORTANT
: The REM3 is not compatible with the
RPT1 and will not benefit from the additional range.
Dimensions
8cm x 3.4cm x 1.5cm (3.1in x 1.3in x 0.6in)
Standards
EN 50131-3 Grade 2 Class II
Step Action on Keypad
Details
1
[
]
+
[
MASTER
CODE
]
The
[
]
key will flash.
LED/key on = programmed user.
[
PARTITION
MASTER
CODE
]
may also be used.
2
[
USER
NUMBER
]
2 digits: 01 to 32
3
[
CODE
]
Enter 4- or 6-digit code
4
[
CONFIRM
CODE
]
Re-enter 4- or 6-digit code
5
[
LEARN
REMOTE
]
Press and hold the Information key (
[i]
) on
the designated remote.
Important:
For parti-
tioned systems, go to step 6. For non-parti-
tioned systems, go to step 2 to add another
remote or press
[
CLEAR
]
to exit.
6
[1]
and/or
[2]
+
[
ENTER
]
Assign the user to one or both partitions, then
press
[
ENTER
]
.
Go to step 2 or press
[
CLEAR
]
to exit.
[703]
Arming/Disarming Options 1
Option
OFF
ON
[1]
One-touch regular arming
Disabled
Enabled
[2]
One-touch stay arming
Disabled
Enabled
[3]
One-touch sleep arming
Disabled
Enabled
PGM Key Assignment
The REM3 provides six PGM keys. See sections
[610]
to
[642]
in the panel to
define the six PGM keys and two combo keys:
One-Touch Programming
Program the REM3 to enable one-touch mode to disarm your system and/or
trigger PGMs. By default, the REM3 is set to require code entry. Section
[360]
is used to configure all odd and even-numbered REM3s, while sections
[361]
to
[376]
are used to configure REM3s by pairs.
PGM1
[9]
PGM2
[0]
PGM3
[x]
PGM4
[
]
PGM5
[ ]
PGM6
[ ]
PGM
[x] + [
]
PGM
[ ] + [ ]
Default:
[B]
[C]
[D]
[E]
[5]
[6]
[
SLEEP
]
[
SLEEP
]
[610]
ALL RC
S
___
___
___
___
___
___
___
___
IMPORTANT:
When section
[610]
is accessed, the panel will copy the saved value of that
section to all remotes.
[611]
RC#1
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
[642]
RC#32
___
___
___
___
___
___
___
___
[360] Odd-Numbered REM3s
[1]
PGM activate/deactivate
[2]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[3] & [4]
N/A
N/A
Even-Numbered REM3s
[5]
PGM activate/deactivate
[6]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[361] REM3 #1
[1]
PGM activate/deactivate
[2]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[3] & [4]
N/A
N/A
REM3 #2
[5]
PGM activate/deactivate
[6]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[376] REM3 #31
[1]
PGM activate/deactivate
[2]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[3] & [4]
N/A
N/A
REM3 #32
[5]
PGM activate/deactivate
[6]
Disarm
OFF
=
Code entry
OFF
=
Code entry
ON = One-touch
ON = One-touch
[
SLEEP
]
- Empty / Button disabled
[1]
-
Regular / Regular Force arming
[2]
-
Stay / Stay Force arming
[3]
- N/A
[4]
- Sleep / Sleep Force arming
[5]
-
PGM Activation (Event Group #22)
[6]
- PGM Activation (Event Group #23)
[7]
- N/A
[8]
- Panic 1
[9]
- Panic 2
[A]
- Panic 3
[B]
- PGM Activation (Event Group #8)
[C]
- PGM Activation (Event Group #9)
[D]
- PGM Activation (Event Group #10)
[E]
- PGM Activation (Event Group #11)
[F]
- Paramedic alarm
PGM Key Definitions Table
Printed in Canada 01/2012
See reverse for REM3 Diagnostic Mode instructions.