background image

Contact Information:

Parker Hannifi n Corporation

Refrigerating Specialties Division

2445 South 25th. Avenue 
Broadview, IL 60155-3891

phone (708) 681-6300 
fax (708) 681-6306

www.parker.com

Product Bulletin 22-05 A

Outlet Pressure Regulator

Type: A4WO, A4WOB, A4WOS, A4WOBS, A4WOK,
  

A4WOBK, A4WOE, A4WOES

Size: 20 - 50 mm (

3

4

” to 2”)

Design Pressure Rating: 32 bar (464 psig)

Purpose:

The A4WO outlet pressure 
regulators modulate the fl ow of 
refrigerant gas or liquid to maintain 
a constant downstream pressure.  
This improved design has a higher 
working pressure, greater working 
temperature range than competitive 
products, and minimizes the effects 
of system impurities for a more 
durable operation.  The A4WOs most 
benefi cial features are its stainless 
steel and aluminum construction, 
which allows it to withstand corrosive 
environments and its overall light 
weight minimizes installation costs.

Product Features:

Suitable for Ammonia, CO

• 

2

, R-22, 

R-404a, and other common 
refrigerants
Designed with corrosion resistant 

• 

material – 304 stainless steel and 
aluminum
No body wearing surfaces

• 

Stainless steel components are 

• 

resistant to wiredrawing
Improved performance at low loads 

• 

with a turn down ratio of 10% of 
capacity

Design drastically reduces foreign 

• 

material to fl ow from inlet to 
diaphragm/seat and piston cavity
Light weight

• 

Can be mounted in a horizontal 

• 

and vertical position
Several control options available

• 

Fluid temperature rating: -60

• 

o

C to 

116

o

C (-76

o

F to 240

o

F)

Ambient temperature rating: -40

• 

o

to 60

o

C (-40

o

F to 140

o

F)

Complies with Pressure Equipment 

• 

Directive 97/23/EC

A4WOB

A4WOS

A4WO

A4WOB

A4WOBS

Patent Pending

Summary of Contents for A4WO

Page 1: ...eatures are its stainless steel and aluminum construction which allows it to withstand corrosive environments and its overall light weight minimizes installation costs Product Features Suitable for Am...

Page 2: ...ectric Shut Off S or a Electric Wide Open Bypass B The bonnet which contains the 3 range set spring and adjustment stem The A4WO is a normally closed valve furnished with socket weld and weld neck opt...

Page 3: ...n diagram is blocked off at the port plate This passage N is used for the A4W inlet regulator variation and is not required for a standard A4WO outlet regulator A plug is installed at the factory to p...

Page 4: ...gh the pilot plug because the pilot plug piston is fully seated Simply de energize the B feature on the valve to regulate A4WOS Principle of Operation The port plate for the A4WOS is the same port pla...

Page 5: ...are factory set for a given set pressure The seal cap is wired to the bonnet cap screw and the wires are sealed with a lead seal The relief pressure setting is stamped on the seal Note if the lead se...

Page 6: ...weld valves require that the pipe be inserted into the socket until bottomed against the stop The pipe is then to be backed out approximately 1 16 of an inch before welding Use of welding rings is op...

Page 7: ...he pilot assembly 17 21 on an A4WO is required then the compression must be taken off the range spring as described above and the bonnet bolts 4 removed If a solenoid feature is incorporated the solen...

Page 8: ...12 14 18 16 19 20 21 22 23 24 25 26 27 29 31 28 32 30 34 33 23 48 47 46 45 44 35 36 37 38 39 40 41 42 43 A4WO Exploded Parts View A4WOS shown Note The port plate for a A4WO and A4WOE outlet pressure...

Page 9: ...46 49 Port Plate A4WOES Only 208944 208944 208944 208944 208944 35 42 Piston 208778 208779 208780 208781 208782 35 39 Spring Piston 208795 208796 208797 208798 208799 35 39 41 42 Wear Seal Piston 2088...

Page 10: ...0 0 mm 3 54 90 0 mm 3 54 D 266 7 mm 10 5 299 5 mm 11 79 312 7 mm 12 31 E 41 4 mm 1 63 53 1 mm 2 09 49 3 mm 1 94 A4WO Butt Weld BW Dimensions A B C D E Dimension Port Size 20 25 mm 3 4 1 32 mm 1 1 4 40...

Page 11: ...ient temperatures The higher fluid temperatures require lower ambient temperatures for the maximum coil temperature not to be exceeded Conversely low fluid temperatures permit higher ambient temperatu...

Page 12: ...s Division Defective products or parts thereof returned to the factory with transportation charges prepaid and found to be defective by factory inspection will be replaced or repaired at Refrigerating...