background image

Bulletin TI-SteamSR-M 

Installation, Operation and Maintenance Manual

Technical Information

 

Balston

®

 Series "SR" Steam Filters

Parker Hannifin Corporation

Industrial Gas Filtration and 

Generation Division

Haverhill, MA  •  1-800-343-4048

www.balstonfilters.com

1

The Balston 23SR Steam Filter contains a patented Microfibre

®

 

Filter Cartridge in a rugged stainless steel housing designed 
specifically for steam service.  Included as standard items with 
the 23SR Steam Filter are a stainless steel condensate drain 
and high quality bleeder valve.  The unit as received is complete 
and ready for installation.

As shown in the cutaway drawing, steam enters the housing 
into an expansion chamber, where much of the condensate is 
knocked out of the steam as a result of the abrupt change in 
flow direction and velocity.  The steam then flows upward in the 

Balston SR Steam Filters are in full compliance with the 
requirements of the United States Food, Drug and Cosmetic 
Act.  These filters may be used with steam, air, and other gases 
which directly contact food and food ingredients, including 
milk, alcoholic and non-alcoholic liquids.

These filters also meet the regulations for Indirect Food Ad-
ditives used as Basic Components for Repeated Use Food 
Contact Surfaces as specified in 21 CFR Part 177, and Current 
Good Manufacturing Practices, 21 CFR Part 110.

The Balston SR Steam Filters are in full compliance with the 3A 
Accepted Practices (Number 609-03) for producing steam of 
culinary quality.

The Balston SR Steam Filters have also been accepted by the 
USDA for use in federally inspected meat and poultry plants.

Bulletin TI-SteamSR-M

USFDA, USDA, and 3A Compliance

housing, through the Balston Grade SR Microfibre

®

 Filter Cartridge (outside-to-inside flow), and then downward to the exit port.  

The Grade SR Microfibre Filter Cartridge, rated at 98+% efficiency for 0.01 micron and larger particles, removes essentially all 
the suspended solid particles and the remaining water droplets.  The water draining from the filter cartridge and the expansion 
chamber is automatically removed from the housing by the automatic condensate drain.

The Balston Grade SR Microfibre Filter Cartridge, the heart of the Model 23SR Filter, combines rugged construction with re- 
markably efficient filtration of solid particles and liquid droplets.  Solid particles remain trapped in the depth of the filter car-
tridge, while liquid water drips from the filter cartridge to the automatic drain.  The Microfibre Filter Cartridge is constructed from 
chemically inert borosilicate glass fibers and a fluorocarbon resin binder.  The filter cartridge is completely free of impurities 
which could extract into the steam, and is in compliance with USFDA regulations as stated.   

The Balston 23SR Steam Filter
What it is - How it works

Installation, Operation, and Maintenance Manual

Balston® Series "SR"

Steam Filters

Summary of Contents for Balston SR Series

Page 1: ... CFR Part 110 The Balston SR Steam Filters are in full compliance with the 3A Accepted Practices Number 609 03 for producing steam of culinary quality The Balston SR Steam Filters have also been accepted by the USDA for use in federally inspected meat and poultry plants Bulletin TI SteamSR M USFDA USDA and 3A Compliance housing through the Balston Grade SR Microfibre Filter Cartridge outside to in...

Page 2: ...hour respectively Each filter has its own steam trap to avoid short circuiting A master trap at the end of the inlet manifold disposes of most condensate before it reaches the filters Manifolds can be connected to flow from left to right or right to left allowing for convenient installation For 2 Steam Lines The Balston SP4 23 75SR four 23 75SR steam filters manifolded together handles steam flow ...

Page 3: ... The Mud Leg and manifold end plugs see installation diagram have not been installed The filter may be installed to flow from left to right or from right to left whichever is more convenient for your application The inlet manifold is at a lower level than the outlet manifold This prevents steam conden sate from climbing into the filter housings Make sure that incoming steam is connected to this lo...

Page 4: ...tap water A continuous discharge of live steam accompanied by a violent bucket rattle indicates that the trap has lost its prime This can usually be corrected by closing the inlet valve for a few minutes and then gradually opening it Caution Remove all steam pressure from filter before removing trap After backflushing reassemble trap to filter using Rectorseal TM 5 or equivalent on the threads How...

Page 5: ...rial Gas Filtration and Generation Division Haverhill MA 1 800 343 4048 www balstonfilters com 5 Replacement Parts Order by part number Not by item number To ensure consistent product performance and reliability use only genuine Balston replacement parts and filter cartridges Replacement Parts for 23 75SR SP2 23 75SR SP3 23 75SR SP4 23 75SR and SP6 23 75SR ...

Page 6: ...lletin TI SteamSR M 03 18 2014 Parker Hannifin Corporation Parker Manufacturing UK Ltd Gas Separation Filtration Division EMEA Dukesway Team Valley Trading Estate Gateshead Tyne Wear NE11 0PZ United Kingdom Ph 44 0 191 402 9000 www parker com gsfe Parker Hannifin Corporation Industrial Gas Filtration and Generation Division 4087 Walden Ave Lancaster NY 14086 Tel 716 686 6400 Fax 877 857 3800 www b...

Reviews: