Summary of Contents for PF250S-PP

Page 1: ...rʼs responsibility to have all operators and service personnel read and understand this manual OPERATING MANUAL AND SCHEMATIC P PRINTED IN U S A 2015 Illinois Tool Works Inc Positive Placement MODEL PF250S PP Metal Connector Nailer 511999 1 03 15 ...

Page 2: ...13 TROUBLESHOOTING 14 WARRANTY 15 ACCESSORIES 16 The PASLODE PF250S PP Positive Placement Metal Connector Nailer is a quality built tool designed for use in residential framing applications This tool will deliver efficient dependable performance when used according to the manufacturerʼs guidelines Please study this manual including the safety instructions to fully under stand the operation of this...

Page 3: ...g must be capable of discharging tool air pressure when disconnected from the air supply OPERATING AIR PRESSURE 90 to120 psi 6 2 to 8 3 bar Select the operating air pressure within this range for best tool performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE NAIL LENGTH 1 1 2 to 2 1 2 SHANK DIAMETER 131 to 162 TOOL AND FASTENER SPECIFICATIONS NAIL COATINGS Heat Treated Galvanized Heat Tre...

Page 4: ... DISCONNECT THE TOOL WHEN NOT IN USE CARRY THE TOOL BY THE HANDLE the air hose or with the trigger depressed since you could drive a fastener unintentionally and injure yourself or someone else because people who are not familiar with the tool may handle it and injure themselves or others tool to a new location The tool must never be left unattended Always disconnect the tool from the air line whe...

Page 5: ...N Depress the work contacting element and hold it against the work surface before pulling the trigger After each fastener is driven completely release the trigger and lift the tool from the work surface Driving of Nails The tool is equiped with a sequential gray trigger to operate the tool Step No 1 Grasp the nailer handle firmly Loading of Nails Step No 2 Insert one or two strips of fasteners int...

Page 6: ...l counter clockwise to decrease fastener depth Turn thumbwheel clockwise to increase fastener depth Thumbwheel The PF250S PP is equipped with a tool free Quick Clear feature to allow you easy access to the nose and magazine for clearing a jam Clearing a Jam 3 Slide the magazine back in the mounting bracket until the front of the magazine clears the guide pins located on the nose Pivot or remove th...

Page 7: ...the bottom of each branch line A refrigerant type dryer is installed on the system Air hoses are kept as short as practical A regular maintenance program is followed Outdoor Air System Installation Be certain that A moisture trap and a filter regulator lubricator are installed at the compressor Air hoses and fittings are large enough so that air flow is not restricted Minimum hose size is 3 8 inch...

Page 8: ...e tool X 1 2 X 0 051scfm 100psi 18 36 scfm This number is found in the Air Consumption Chart In this example using the air consumption chart we find that a compressor providing at least 19 scfm of air is required Because in compressors approximately 1 hp is required to produce 4 scfm a compressor of at least 5 hp is required Calculated Required Piping For example given a 20 hp electric compressor s...

Page 9: ...en Compact Design Left Right Rafter Hook Accommodates left or right handed operators Nail Guide Helps guide fasteners into magazine for quick loading Sequential Trigger Lock Out Eliminates blank firing Promotes driver blade durability End Cap Inline Magazine Narrow design for balance maneuverability operation Able to get into tight spots and unobstructed Tool less Adjustable Depth of Drive Quick C...

Page 10: ...2037 1 Shear Block 77 513109 1 Label Fastener Usage Follower Release 78 511819 1 Magazine 1 End Cap Magazine 64 502061 1 Spring 23 1 Blade Seal 79 502332 1 Rafter Hook Denotes Normal Wear Items Make sure Warning Label Part No 511822 is properly affixed Replace if necessary Label available at no charge through the Service Department Apply Loctite 242 Blue PartNo 093500 Denotes New Change WARNING All...

Page 11: ... 21 20 19 18 17 28 30 31 32 5 33 34 56 55 71 60 58 59 57 53 52 37 35 92 5 68 69 67 61 62 66 64 63 75 74 73 78 76 65 Positive Placement Metal Connector Nailer Torque Values IN LBS 15 20 180 140 210 80 90 140 70 Poppet Assembly 502920 Seal must be installed in this position Note Install check band with thick side down 70 72 79 84 81 83 82 80 85 89 90 86 87 88 91 11 41 73 180 25 26 27 77 93 ...

Page 12: ...acing any part or parts it is important to check the tool for proper operation This ensures that the tool was put together correctly is safe to use and will perform the job properly Ensure that all hardware is tight Ensure that the work contacting element is installed correctly in relation to the trigger and that both parts move freely Ensure that the magazine is properly attached Ensure that the ...

Page 13: ...fficient operation Promote operator safety and efficient tool operation Prevent jamming of fasteners Assure long life and proper operation of tool Keep tool operating efficiently and maintain Paslode tool warranty Open manual petcock most air supply systems have such a valve Fill with Paslode pneumatic tool lubricant Part No 403720 Wash with soap and water or follow manufacturers instruc tions Check ...

Page 14: ...ol is connected to air Increase air pressure do not exceed 120 psi Increase air flow to tool use larger air lines 3 8 inch ID minimum Reduce air pressure Check magazine for proper fasteners Magazine fol lower should slide freely Clean as needed to remove debris Make sure correct fasteners are being used Use fasteners that meet Paslode specifications only Increase air flow to tool use larger air lines...

Page 15: ...15 An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills Illinois 60061 TOOL WARRANTY AND LIMITATIONS TOOL WARRANTY P than Probe ...

Page 16: ...rt No 403734 Tool Cleaner Ideal cleaner for all Paslode tools Part No 219348 Safety Glasses Clear Part No 401382 ACCESSORIES P An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills Illinois 60061 3105 Lubricant 5 gram tube Part No 219188 Paslode and Positive Placement are registered trademarks of ITW All other trademarks are property of their respective owners ...

Page 17: ... Lentes de Seguridad Claros Pieza No 401382 ACCESORIOS PUBLICADO EN EE UU 2014 Illinois Tool Works Inc P Una Compañia de Illinois Tool Works 888 Forest Edge Drive Vernon Hills Illinois 60061 3105 El limpiador ideal para todas las herramientas Paslode Lubricante en Tubo de 5 gramos Pieza No 219188 Paslode y Positive Placement es una marca registrada de ITW Las marcas registradas son propiedad de su...

Page 18: ... de la herramienta excepto según lo estipulen las leyes pertinentes PASLODE NO SERÁ RESPONSABLE EN NINGÚN CASO POR NINGÚN DAÑO DIRECTO INDIRECTO O CONSECUENTE INCLUYENDO PERO SIN LIMITARSE CUALQUIER DAÑO RESULTADO DE LA PÉRDIDA DE PRODUC CIÓN O GANANCIAS ANTICIPADAS EL DETERIORO DE MATERIALES AUMENTOS EN EL COSTO DE OP ERACIÓN O CUALQUIER OTRO Paslode garantiza que sus herramientas mecánicas sus p...

Page 19: ... presión de aire Abra el seguro delantero quite el sujetador obstruido y cierre bien el segurro Compruebe si el cargador tiene los sujetadores apro piados El transportador debe deslizarse sin dificultad Límpielo para quitar cualquier suciedad Verifique que se usen los sujetadores apropiados Use solamente sujetadores que reúnan las especifica ciones de Paslode Aumente el flujo de aire a la herramienta ...

Page 20: ...cionamiento de la herramienta Par prevenir que se obstruyan los sujetadores Para prolongar la vida de la herramienta y su funcionamiento adecuado Para que la herramienta continúe funcionando eficientemente y mantener vigente la garantía de Paslode Abra la llave de escape La mayoría de los sistemas neumáticos la tienen Llene con lubricante neumático N 403720 474 ml Lave con agua y jabón o siga las i...

Page 21: ...anque del compresor del aire para eliminar cualquier humedad cuando haga mucho frío o el grado de humedad sea muy alto Poniendo una pequeña cantidad de descongelante en el tanque evitará que la humedad se congele Probar la Herramienta Después de Darle Servicio Después de reemplazar una o más piezas es importante comprobar si la herramienta funciona como es debido Esto asegura que todas las piezas ...

Page 22: ... 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 24 23 22 21 20 19 18 17 25 27 28 29 5 30 31 53 52 68 57 55 56 54 50 49 34 32 88 5 65 66 64 58 59 63 61 60 72 71 70 74 73 62 15 20 180 140 210 80 90 140 70 67 69 75 80 77 79 78 76 81 85 86 82 83 84 87 11 38 70 180 Ensamblado De Válvua 502908 Ensamblado DeGatillo 513105 Ensamblado De La Válvula Principal 502920 Nota Instale precinto de control con el lad...

Page 23: ...97913 1 O Ring 502044 1 41 502059 1 Spring Valve Pin 42 1015358 1 O Ring 43 502045 1 Valve Pin 44 196345 1 O Ring 45 092747 1 O Ring 502060 1 Spring Trigger 49 50 502042 1 O Ring 53 54 002187 5 Lock Washer 55 091545 4 S H C S 1 4 20 x 7 8 56 511824 1 57 513107 1 Bias Lever Pin 58 501410 1 59 511808 1 Bias Lever 60 511821 1 502328 1 62 Magazine Washer 63 502049 1 S H C S 10 32 x 5 8 65 503069 1 Det...

Page 24: ... al ser impulsado CARACTERÍSTICAS Y BENEFICIOS DE LA PF250S PP Desvia el aire del usuario Gancho de Vigas Ensamblé al derencho Ó al izquierdo Guía de Clavos Ayuda a guiar los clavos en el cargador para carga rapida Diseño Compacto Ligero en lugares apretados Cargador En Linea Para balancé Y agilidad sin para operación sin barreras Tapón Trasero Cierre de Disparo Elimina disparos en blanco Sin herr...

Page 25: ...sando la tabla de consumo de aire este ejemplo demuestra que se necesita un compresor que propor cione 19 pies min estándar de aire por lo menos Como en compresores se necesita aproximadamente 1 hp para proporcionar 4 pies min estándar se requi ere por lo menos un compresor de 5 hp Cómo Calcular la Tubería Necesaria Por ejemplo si un compresor eléctrico de 20 hp proporciona aproximadamente 80 pies...

Page 26: ...o inferior de cada línea secundaria Se haya instalado en el sistema un secador tipo refrigerante Lasmanguerasdeaireseantancortascomosea posible Se siga un programa regular de mantenimiento Instalación de Un Sistema Neumático para Exteriores Asegure Que Se hayan instalado en el compresor un colector de humedad y un filtro regulador lubricador Las mangueras de aire y los adaptadores tengan la longit...

Page 27: ...nspección Instalación del cargador Quick Clear 1 En el cargador coloque el agujero grande de montaje sobre la oreja de montaje redon da en la herramienta 2 Alinee los agujeros de montaje en el car gador con el pernos de guía en la nariz Pasadores de Guía 6 3 continuación los pernos de guía de la nariz con los orificios derecha hasta que esta firmemente apretado la izquierda para para disminuir la ...

Page 28: ...arla llame de inmediato al representate de Paslode PELIGRO La presión de aire en la herramienta nunca debe exceder 120 psi FUNCIONAMIENTO DE LA HERRAMIENTA Paso 1 Agarre el mango firmamente Mueva el seguidor de clavos hacia la parte trasera del cargador hasta que se cierre en la posción de carga Carga de Sujetadores Paso 2 Meta la tira de clavos en la parte de arriba del cargador con la punta de l...

Page 29: ... llamado elemento de contacto para prevenir cualquier disparo accidental Nunca manipule indebidamente deje inoperante ni quite el elemento de contacto No use la herramienta a menos que dicho elemento funcione correctamente porque podría producirse un disparo imprevisto DESCONECTE LA HERRAMIENTA CUANDO NO LA ESTE USANDO Siempre desconecte la herramienta de la línea de aire comprimdo cuando no la es...

Page 30: ... de 1 4 N P T El acoplamiento debe ser capaz dedescargar la presión de aire en la herramienta cuando sea desconectada del suministro de aire OPERACION de PRESIÓN de AIRE 90 hasta120 p s i 6 2 hasta 8 3 bar Seleccione una presión de aire dentro de esta gama para obtener el mejor rendimiento NO EXCEDA LA PRESIÓN DE AIRE RECOMENDADA LONGITUD DEL CLAVO 1 1 2 DIAMETRO DEL TALLO 131 162 ESPECIFICACIONES...

Page 31: ...ricante Lea cuidadosamente este manual y las instrucciones de seguridad para comprender como usar la herrmienta correctamente CONTENIDO SPECIFICACIONES DEL LA HERRAMINETA Y SUS SUJETADORES 3 INSTRUCCIONES DE SEGURIDAD 4 INSTALACION Y OPERACION DE LA HERRAMINETA 5 6 SISTEMAS DE AIRES 7 8 BENEFICIOS DE LA HERRAMIENTA 9 ESQUEMA CON LISTA DE PIEZAS DE REEMPLAZOS 10 11 MANTENIMIENTO 12 13 DETECCION Y C...

Page 32: ...STE MANUAL El cliente tiene la responsibilidad de que todo el personal de operaciones y servicio lea y entienda este manual Manual de Funcionamiento y Esquema P Clavadora de Entramado para Conectores Metálicos Modelo PF250S PP ...

Reviews: