background image

Model 1016 

rev1

  

•  eDIN DMX/RDM Hub 

Manual

 

STATUS INDICATORS 

CONNECTIONS 

POWER

 

Amber

. Steady glow indicates each port

isolated power supply is OK; off indicates 

no  power.  If  all  LEDs  are  off,  check  that 

the module is receiving power.

 

INPUT

 

Amber.

 Steady glow indicates port latched 

to  active  DMX  source.  Input  and  Output 

off on all ports indicates no DMX source.

 

OUTPUT

 

Green

.  Steady  glow  indicates  port  is 

transmitting DMX.  Input and Output off on 

all ports indicates no DMX source.

 

FUNCTION

 

Amber

. Steady glow indicates the current 

operating  mode.  Flashing  indicates  the 

module is in edit mode.

 

OVERVIEW 

The #1016 eDIN 8

-

port RDM Hub brings flexibility to 

single  universe  DMX512  distribution  systems. 

Through  the  use  of  automatic  DMX512  sensing, 

across four operating modes, any port may detect 

a  roving  DMX512  source  and  act  as  an  input;  or 

two  inputs  may  be  merged  together;  or  the  user 

may  select  between  inputs;  or  a  priority  scheme 

may be invoked.  The module is RDM discoverable 

and configurable, as well as daisy

-

chainable.

 

The  eDIN  RDM  Hub  features  terminal  strips  that  can  be 

removed from the card to facilitate easy wiring installation 

or  replacement.  Make  the  following  connections, 

WITH 

THE POWER TURNED OFF.

 

 

POWER

 

The RDM Hub will operate on a range of voltages from 9

-

30  volts  DC.  Each  eDIN  module  requires  250mA.        

Observe  the  correct  polarity  when  connecting  to  V+  and  

V

-

.  A second set of terminals are provided as a thru con-

nection  to  other  eDIN  modules.  The  EARTH  GND  termi-

nal must be connected to the enclosure

s chassis or elec-

trical ground terminal to ensure EMC compliance.

 

 

DMX512

 

DMX512 (DMX) connections consist of a shield and data 

pair.    DMX  usually  comes  from  a  lighting  console,  Path-

port

®

 gateway, architectural controller or another #1016. 

 

   Connect DATA+ and DATA

-

 to D1+ and D1

-

.  Observe 

the  same  polarity  convention  throughout  the  system.  

Connect  the  cable  shield  or  common  wire  to  the  SHLD 

COM terminal. 

 

DMX TERMINATE 

Each port on the RDM Hub is auto

-

terminated as required 

by its operation.

 

CONFIGURATION 

 

To configure, press and hold the function button until the 

current  Function  LED  begins  to  flash.  Momentarily  re-

lease then press the button to cycle through the operating  

mode  options.    Once  the  desired  mode  is  selected,      

release  the  button.  After  three  seconds,  the  LED  will 

change to a steady glow and the new mode will take ef-

fect.

 

V-

V+

V-

GRO

U

N

D

EAR

TH

V+

NC

NC

D1-

D1
+

NC

SHL

D

C

OM

NC

D1
+

C

OM

SHL

D

D1-

12

 Watts

 M

A

X

9-30 V

DC

POWER

 IN

NC

NC

D1
+

C

OM

SHL

D

D1-

NC

NC

D1
+

C

OM

SHL

D

D1-

NC

NC

D1-

D1

+

NC

SHL

D

C

OM

NC

D1

+

C

OM

SHL

D

D1-

NC

NC

D1

+

C

OM

SHL

D

D1-

NC

NC

D1

+

C

OM

SHL

D

D1-

RDM Hub

Priority

RDM A/B

Rev.0

8 CHANNEL 

R

D

H

U

B

CO
M

A/B

Merge

Reviews: