background image

 

 

 

 

 

 

 

PCE Americas Inc. 
711 Commerce Way  
Suite 8 
Jupiter 
FL-33458 
USA 
From outside US: +1 
Tel: (561) 320-9162 
Fax: (561) 320-9176 
info@pce-americas.com 
 

PCE Instruments UK Ltd. 

Units 12/13  

Southpoint Business Park 

Ensign way 

Hampshire / Southampton 

United Kingdom, SO31 4RF 

From outside UK: +44 

Tel: (0) 2380 98703 0 

Fax: (0) 2380 98703 9 

info@pce-instruments.com 

 

www.pce-instruments.com/english 

www.pce-instruments.com 

Manual 

Color Meter MK350N Plus 

 

Version 1.0 

Date of creation: 23.07.2015 

Date of last change: 25.08.2015

 

 

Summary of Contents for MK350N Plus

Page 1: ...uments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments com english www pce instruments com Manual Color Meter MK350N Plus Version 1 0 Date of creation 23 07 2015 Date of last change 25 08 2015 ...

Page 2: ...ion 8 2 3 Strap and Neck Strap Installation 9 2 4 Screen Wiper Usage Method 10 2 5 Power On Off 10 2 6 Dark Calibration 11 2 7 Option Function Setting 12 2 8 System Reset 14 3 System overview 15 3 1 Measurement Modes Introduction 15 3 2 Continuous Measurement Introduction 20 3 3 Customizing BASIC Mode List 21 3 4 BROWSER Mode Introduction 22 3 5 PC Connection 23 4 Specification 24 4 1 Product Spec...

Page 3: ...Manual 3 1 Introduction 1 1 Packing Contens Please check MK350N PLUS packing before use contact your agent if there are missing items ...

Page 4: ...e at any time high mobility 3 3 5 colour touch screen simple interface easy to use 4 SD card storage easy to transfer data 5 Built in file browser allows for quick access to previously saved data 6 Spectrum diagram and including 35 light unit of measure 7 Flicker measurement for disease prevention and health check ...

Page 5: ...t expose the battery to heat fire or water moisture When disposing used old batteries wrap with insulation tape to shield the battery from electrical contact with metallic objects which might ignite a fire or explosion If the unit is plugged into the power adapter and the battery seems to be overheating or if there is smoke or peculiar odors emanating from the unit unplug immediately to avoid the ...

Page 6: ... after removing battery cover Note 1 Please charge the battery for 6 hours at first time usage 2 To avoid any interruption while measuring please check battery status before use 3 Please purchase a new battery if it gets low easily after being fully charged which means battery life comes to an end 4 Usage time will depend on battery life MK350N PLUS battery can operate 5 hours after being fully ch...

Page 7: ... Power Off Status Users can check power key it will light in red while charging and light off after being fully charged 3 Power On Status Users can check MK350N PLUS screen it will appear a lightning symbol to indicate charging and a lightning symbol will disappear after being fully charged ...

Page 8: ...Manual 8 2 2 Memory Card Installation Installing the SD card Remove the SD card Note 1 Check SD card status refer 2 7 storage 2 Check SD card storage method refer 3 2 Save Measured Data ...

Page 9: ...eck Strap Installation Strap installation 1 Unscrew the strap 2 Tie the strap to the strap hole of MK350N PLUS 3 Tie the strap to the sensor cover 4 Screw the strap Neck strap installation Tie on the strap hole of MK350N PLUS ...

Page 10: ...an remove the dirt easily 2 Strong absorbent and no effect after repeated washing 3 Can use bleach for wash but do not iron the wiper 2 5 Power On Off Turn on the power Press the power key for 1 second Turn off the power Press the power key for 5 seconds ...

Page 11: ...libration automatically Note Suggest to execute dark calibration every time when turning on MK350N PLUS 2 When using MK350N PLUS users can execute dark calibration manually Users can go to measurement page then select MEASUREMENT SETTING DARK CALIBRATION to execute dark calibration manually ...

Page 12: ...Manual 12 2 7 Option Function Setting Go to main menu and select OPTION to start system setting ...

Page 13: ...Manual 13 Note 1 Pease set up date and time before saving the files 2 Users can set up auto power off time to saving battery power Default auto power off setting is 10 minutes ...

Page 14: ...Manual 14 2 8 System Reset Users can press the reset key to turn off the system if system crashes ...

Page 15: ...Manual 15 3 System overview 3 1 Measurement Modes Introduction 4 kinds of measurement modes ...

Page 16: ...troduction 1 Measurement mode BASIC SPECTRUM CIE1931 CIE1976 2 Integration mode Auto Manual 3 Capture function One time Continuous 4 Battery capacity 5 Measurement result 6 Measurement setting 7 Back to main menu 8 Save data ...

Page 17: ... sensor head at light source with suggest angle 30 2 At appropriate distance then press capture key 3 After beep sound measured data will be displayed on the screen Note Operation sound setting refer 3 3 Operation sound ...

Page 18: ...Manual 18 Save measured data Note 1 Save format setting refer 3 3 Save format 2 Available capacity of SD card refer 2 7 Storage ...

Page 19: ...Manual 19 Please go to measurement page to do measurement settings ...

Page 20: ...ent Introduction Note 1 Continuous measurement has no beep sound after press capture key 2 Users cannot save the measurement data while processing continuous measurement 3 Adjust the integration time is only allowed in the manual mode ...

Page 21: ...Manual 21 3 3 Customizing BASIC Mode List 1 Tap the box of measuring unit 2 Select an item from the list 3 The new data item will be displayed ...

Page 22: ...eview historical data that was previously saved to the SD card 1 Press the BROWSER icon 2 A file browser will now show the files on the SD card If you select an excel file a review menu will be displayed 3 Press any of the icons to review the data 4 Displaying the data of excel file ...

Page 23: ... directly to the MK350N PLUS using the enclosed USB cable This allows your PC to use Windows Explorer to view data or transfer data that was saved onto the MK350N PLUS SD Card Excel files or JPG files After connection the MK350N PLUS screen will display as shown ...

Page 24: ...ates 1 CIE 1931 x y Coordinates 2 CIE 1976 U C S u v Coordinates 3 CIE 1921 XYZ colour space 4 Peak Wavelength 5 Delta uv 6 x y u v 7 Correlated Colour Temperature CCT 8 Colour Rendering Index Ra R1 R15 9 Colour Quality Scale CQS 10 TLCI 11 Flicker Percentage 12 SP Ratio Scotopic and Photopic 13 Foot Candle Digital Resolution 16 bits Dark Calibration Yes Stray Light 25 dB max 1 Wavelength Data Inc...

Page 25: ...ng Temperature 0 35 C Storage Temperature 10 40 C Language Selection English Traditional Chinese Simplified Chinese Japanese Spanish German French Italian Russian 1 Use the input of 550 nm single frequency and measurement the range of optical 40 nm 2 Input source must be a stable light source The company reserves the right to change product specifications if it has any changes will not give any no...

Page 26: ...e contact PCE Instruments 5 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 5 2 PCE Americas By post PCE Americas Inc 711 Commerce Way Suite 8 Jupiter 33458 FL USA By phone 561 3209162 ...

Reviews: