background image

 

 

 

Data Logger

     PCE-THB 40

Your  purchase  of  this

HUMIDITY/BAROMETER/

TEMP.  MONITOR  with

S D  

C A R D

DATALOGGER  marks  a

step  forward  for  you

into 

the 

field 

of

precision measurement.

A l t h o u g h  

t h i s

DATALOGGER 

is 

a

complex  and  delicate

instrument,  its  durable

structure 

will 

allow

many  years  of  use  if

p r o p e r  

o p e r a t i n g

t e c h n i q u e s  

a r e

developed.  Please  read

t h e  

f o l l o w i n g

instructions 

carefully

and  always  keep  this

manual 

within 

easy

reach.

       OPERATION MANUAL

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

info@pce-americas.com

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

info@pce-instruments.com

Summary of Contents for PCE-THB 40

Page 1: ...i q u e s a r e developed Please read t h e f o l l o w i n g instructions carefully and always keep this manual within easy reach OPERATION MANUAL PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL...

Page 2: ...4 3 15 Hanging unit with sticker 4 4 MEASURING PROCEDURE 5 5 DATALOGGER 5 5 1 Preparation before execute datalogger function 5 5 2 Datalogger 7 5 3 Check time information 7 5 4 SD Card Data structure...

Page 3: ...pacitance type humidity sensor professional and high accuracy for humidity measurement Professional barometer unit hPa mmHg inHg SD card capacity 1 GB to 16 GB Large LCD display easy readout Microcomp...

Page 4: ...t ON OFF Set the unit of Barometer Update Time Approx 1 second if measuring data of Display is changed Data Output RS 232 USB PC computer interface Connect the optional RS232 cable UPCB 02 will get th...

Page 5: ...ble UPCB 02 Data Acquisition software SW U801 WIN 2 2 Electrical Specifications 23 5 Humidity Range 10 to 90 R H Resolution 0 1 R H Accuracy 70 RH 4 reading 1 RH 70 RH 4 RH Temperature Range 0 to 50 3...

Page 6: ...on 3 4 button 3 5 SET button 3 6 Humidity Temp Barometer sensor 3 7 Hanging holes 3 8 Stand 3 9 Battery cover Battery compartment 3 10 Screw for battery cover 3 11 Reset button 3 12 RS 232 output term...

Page 7: ...arometer unit hPa mmHg inHg refer to chapter 7 8 page 15 5 DATALOGGER 5 1 Preparation before execute datalogger function a Insert the SD card Prepare a SD memory card 1 GB to 16 GB optional insert the...

Page 8: ...le 20 6 1000 53 Under such situation it should change the Decimal character at first details of setting the Decimal point refer to Chapter 7 5 page 13 e 3 Information of LCD display If the Display sho...

Page 9: ...the Datalogger During execute the Datalogger function Display show the Datalogger indicator press the Logger button 3 2 Fig 1 2 seconds continuously until the Display indicator DATALOGGER is disappea...

Page 10: ...ew file name HBA01001 XLS After exist the Datalogger then execute again the data will save to the HBA01001 XLS until Data column reach to 30 000 columns then will generate a new file for example HBA01...

Page 11: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name HBA0100...

Page 12: ...button Following press the SET button 3 5 Fig 1 once a while in sequence to select the eight main function the display will show Sd F SD memory card Format dAtE Set clock time Year Month Date Hour Mi...

Page 13: ...Fig 1 once again the Display will show text yES Enter to confirm again if make sure to do the SD memory card format then press Enter Button once will format the SD memory clear all the existing data t...

Page 14: ...ower 7 3 Set sampling time When the Display show SP t 1 Use the Button 3 3 Fig 1 or Button 3 4 Fig 1 to adjust the sampling value 5 seconds 10 seconds 30 seconds 60 seconds 120 seconds 300 seconds 600...

Page 15: ...structure of SD card is used the as the decimal with default for example 20 6 1000 53 But in certain countries Europe is used the as the decimal point for example 20 6 1000 53 Under such situation it...

Page 16: ...ill save the setting function with default 7 7 Set RS232 data output ON OFF When the Display show rS232 1 Use the Button 3 3 Fig 1 or Button 3 4 Fig 1 to select the upper Display text to yES or no yES...

Page 17: ...or InHg Text Unit hPA hPa HG mmHg InHg inHg 2 After the unit is selected press the Enter Button 3 2 Fig 1 will save the setting function with default 8 POWER SUPPLY from DC ADAPTER The meter also can...

Page 18: ...the instrument and remove the battery 3 Replace with DC 1 5 V battery UM4 AAA Alkaline heavy duty x 6 PCs and reinstate the cover 4 Make sure the battery cover is secured after changing the battery 10...

Page 19: ...ad with the following connection will be required to link the instrument with the PC serial port Meter PC 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2 K resistor Pin 5 The...

Page 20: ...egative D11 D12 Annunciator for Display 01 02 RH 04 hPa 91 inch Hg 80 mm Hg 78 D13 When send the up display data 1 When send the middle display data 2 When send the low display data 3 D14 4 D15 Start...

Reviews: