background image

ISSUED: 03-26-03  SHEET #: 055-9213-2   11-10-04

For customer service call 1-800-729-0307 or 708-865-8870.

Visit the Peerless Web Site at www.peerlessindustries.com

1 of 5

R

Maximum Load Capacity:

75 lb (34 kg)

Model: ACC 912

 Read instruction sheet before you start installation and assembly.

This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.

Installation and Assembly -

Lightweight Cathedral Ceiling
Plate for Projectors

• Installer must verify that the ceiling will safely support

four times the combined weight of all attached equip-
ment and hardware.

WARNING

Summary of Contents for ACC 912

Page 1: ... ACC 912 Read instruction sheet before you start installation and assembly This product is intended for use with UL Listed products and must be installed by a qualified professional installer Installation and Assembly Lightweight Cathedral Ceiling Plate for Projectors Installer must verify that the ceiling will safely support four times the combined weight of all attached equip ment and hardware W...

Page 2: ...ndustries com 2 of 5 Description Qty Part A upper ceiling bracket 1 055 1484 B lower ceiling bracket 1 055 1486 C 1 4 20 x 5 8 carriage bolt 4 520 1175 D 1 4 20 nylock nut 4 530 9413 E 1 4 ID x 3 4 OD washer 4 540 9401 F 14 x 2 5 hex head wood screw 2 5S1 015 C04 G M5 x 8 x 10 mm phillips self tapping screw 1 520 9250 Parts List A B D C E G F ...

Page 3: ...g bracket A with two 14 x 2 5 6 mm x 65 mm wood screws F Installation to Wood Joist Finished Ceiling Exposed Wood Joists or Wood Beam Ceiling Flush Mount Tube Application EXT 002 required Installation to Wood Joist Finished Ceiling Exposed Wood Joists or Wood Beam Ceiling THREADED FITTING WALL CEILING A F Tighten wood screws so that ceiling plate is firmly attached but do not overtighten Overtight...

Page 4: ...pand anchors Cross Section Attachment to a concrete ceiling CONCRETE ANCHOR INSTALLATION FORPRODUCTSAFETYUSEONLY RAWL 5005 OR HILTI HL814 CONCRETE ANCHORS 312x 1 625 8 mm x 41 mm ORDER ACCESSORYFASTENERKIT ACC 200 Installation to Concrete Ceiling Tighten concrete anchor bolts firmly but do not overtighten Overtightening can damage the bolts greatly reducing their holding power Never tighten in exc...

Page 5: ...n column into lower ceiling bracket B and align slot of extension column with one of the holes in lower ceiling bracket B Thread M5 x 10 mm self tapping screw G through lower ceiling bracket B into extension column as shown in detail 1 Note 3 4 extension column FLP series can be used in place of the EXT or ADJ series Two pipe reducers ACC 913 are required for installing the 3 4 column 1 1 2 Extens...