background image

 

 

INSTALLATION MANUAL GUIDE | DATE: 02/2017

 

1

 

 

INSTALLATION MANUAL

 

INDEX

 

 

I) WARNING

 ........................................................................................................ 2 

 

II) INTRODUCTIONS

 .......................................................................................... 2 

 

IV) CODES and REGULATIONS

 ........................................................................ 2 

 

V) MECHANICAL INSTALLATIONS

 ................................................................... 3 

a) Mounting site

 ........................................................................................ 3 

b) Orientation of installations

 .................................................................. 3 

c) Module tilt angle

 ................................................................................... 4 

d) Mounting

 ............................................................................................... 4 

d.1)

 

Mounting using bolt holes

 ................................................. 5 

d.2)

 

Mounting using "Clipping method" and profile insert

 .. 5 

 

VI) ELECTRICAL INSTALLATIONS

 ................................................................... 7 

a) Blocking diodes

 .................................................................................... 7 

b) Over current protection

 ........................................................................ 7 

c) Grounding

 ............................................................................................. 7 

d) Wiring

 .................................................................................................... 9 

 

VII) MAINTENANES

 ......................................................................................... 10 

 

VIII) SAFETY PRECAUTIONS

 ......................................................................... 10 

 

IX) NOTES

 ........................................................................................................ 11 

 

 

Summary of Contents for Peimar

Page 1: ...LLATIONS 3 a Mounting site 3 b Orientation of installations 3 c Module tilt angle 4 d Mounting 4 d 1 Mounting using bolt holes 5 d 2 Mounting using Clipping method and profile insert 5 VI ELECTRICAL INSTALLATIONS 7 a Blocking diodes 7 b Over current protection 7 c Grounding 7 d Wiring 9 VII MAINTENANES 10 VIII SAFETY PRECAUTIONS 10 IX NOTES 11 ...

Page 2: ...signed to operate efficiently in sunlight By modules the solar radiant energy is transformed into electrical energy for using Modules usually be used as one fittings of PV solar system A set of basic PV solar system is consisted of PV solar module controller inverter and storage battery Modules can be used in roof PV solar systems PV stations building and other electric generation application etc ...

Page 3: ...er than 50 pounds per square foot of uniformly distributed wind snow or other loading Not install modules near naked flame or flammable materials When choosing a site avoid trees buildings or obstructions Modules should be mounted to maximize direct exposure to sunlight and to eliminate or minimize shadowing Even partial shadowing can substantially reduce module and system output Furthermore parti...

Page 4: ...and corrosive treatment Installation the modules should has proper ventilation A clearance of 4 5 inches about 115mm or more behind the modules is recommended to permit air circulation and cooler module operation Elevated temperatures lower operating voltage and power and shorten module lifetime Clearance of 1 4 inch 6 35mm or more between modules is required to allow for thermal expansion of the ...

Page 5: ...r cast shadow on the front glass Not to damage the surface of the frame To ensure the clamps overlap the module frame by at least 5 mm To ensure the clamps overlap length is at least 50 mm Clamp material should be anodized aluminum alloy Clamp positions are of crucial importance for the reliability of the installation the clamp centerlines must only be positioned within the clamping area indicated...

Page 6: ...INSTALLATION MANUAL GUIDE DATE 02 2017 6 ...

Page 7: ...rrent protection Whenever necessary to comply with local codes use a fuse or circuit breaker rated for the maximum series fuse rating of the module and the system voltage Always fuse the connections at the battery for safety Refer to the module rating label on module for recommended fuse size Also refer to the charge controller owners manual All electrical components should have ratings equal or g...

Page 8: ... grounding lug to the Aluminum frame using stainless steel M3 M4 or M5 screw and hardware as shown below Note there are two different size grounding holes the smaller of which is being phased out Further build up of hardware for mounting the grounding lug are the same except for the M3 M4 screw and added flat washer is mounted directly under the M3 M4 screw head The star washer is fitted directly ...

Page 9: ...ted in series One module has a pair of male and female waterproof cables and connectors for electrical connection that are pre wired inside the junction box The cables have obvious marks of the positive and the negative Module bypass diodes type is Yangzhou HY Technology Development Co Ltd type 10SQ050 maximum junction temperature rating 200 C The maximum number of modules connected in series must...

Page 10: ...ite to be checked but once per year Under most conditions normal rainfall is sufficient to keep the module glass clean Clean the glass with a soft cloth using mild detergent and water Modules that are mounted fiat 0 tilt angle should be cleaned more often as they will not self clean as effectively as modules mounted at a 15 tilt or greater It is advisable to perform periodic inspection of the modu...

Page 11: ...ower Modules are intended for use in terrestrial applications only thus excluding aerospace or maritime conditions or use with sunlight concentration It is recommended that the module remains packed in the box until time of installation Work only under dry conditions with a dry module and tools since sparks may be produced do not install module where flammable gases or vapors are present Do not dr...

Page 12: ...nditions that produce more current and or voltage than reported at standard test conditions Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to the PV output ...