315-655-8476
n
www.peltectimers.com
619
05/30/14
600 Series
WARNING: Do not bring the hot and neutral to 3 and 5
without a load. This will cause a catastrophic failure to the
timer. This is not covered by warranty.
NOTE: The voltage to the load does not need to be the
same as the voltage to power the timer.
12Volt DC
WALL ADAPTER
OUTDOOR
LIGHTING
Neutral
Hot
12
0V
A
C
12
0V
A
C
50
/6
0H
z
619-1 TIMER
–
+
1 2
3 4 5
PELTEC 6191 Wired into circuit
DAILY/WEEKLY
DIGITAL TIMER
n
User-programmable 24-hour, 7-day digital timer
n
15 different program periods built in: Full week, 7 individual days and
7 multiple-day combinations
n
Set automatic On/Off cycles; use manual override when needed
n
Real-time 24/7 accuracy to the minute
n
12-hour am/pm clock format
n
Set up to 8 On/Off cycles per day
n
On board LED power indicator
n
LCD display shows ON and OFF status
n
Memory backup with onboard battery
n
20 Amp resistive switching capability, maximum
n
Choice of 6 voltages: 120VAC, 230VAC, 24VAC/VDC, 12VAC/VDC
n
Clear protective cover included
n
UL and CE approvals, RoHS compliant
BUTTON FUNCTIONS
FEATURES
SPECIFICATIONS
Dimensions . . . . . . . . . . . . . . . . in inches 23/8H x 23/8W x 13/8D
in mm 60H x 60W x 37D
Supply voltage ranges . . . . 100–130VAC, 200–250VAC,
24VAC/VDC, 12VAC/VDC
Operating accuracy . . . . . . . ±1 second/day at 20°C
Operating temperature . . . -10°C to +55°C
Standards . . . . . . . . . . . . . . . . . UL, CE, RoHS, CUR E166259
619-1
100–130VAC
619-2
200–250VAC
619-3
24VAC/VDC
619-4
12VAC/VDC
619-BRKT
Mounting bracket
619 TIMER OPTIONS
Press
℗
RESET button to reset timer before using.
CLOCK: Press/hold to set current time with Day, Hour, Min buttons.
Press to commence program execution after setting.
TIMER: Press to enter program mode, and to review up to 8 total
programmed on/off cycles.
DAY: In Clock mode, sets the current day of the week.
In Timer mode, selects the built-in program period desired.
HOUR: Sets the hour.
MIN: Sets the minutes.
MANUAL: Press to select ON/AUTO/OFF mode indicator.
RESET: Press to Cancel all settings. Recessed button next to
℗
.
Depress with pencil or ballpoint pen.
ON: Red LED indicator is lit when the internal relay is energized,
closing the Common (3) to NO (5) terminal.
TYPICAL WIRING EXAMPLE