background image

315-655-8476

   

n

  

www.peltectimers.com

619        

05/30/14

600 Series

WARNING: Do not bring the hot and neutral to 3 and 5 
without a load. This will cause a catastrophic failure to the 
timer. This is not covered by warranty. 
NOTE: The voltage to the load does not need to be the 
same as the voltage to power the timer.

12Volt DC 

WALL ADAPTER

OUTDOOR

LIGHTING

Neutral

Hot

12

0V

A

C

 

12

0V

A

C

50

/6

0H

z

619-1 TIMER

+

1 2

3 4 5

PELTEC 6191 Wired into circuit

DAILY/WEEKLY  

DIGITAL TIMER

n   

User-programmable 24-hour, 7-day digital timer

n   

15 different program periods built in: Full week, 7 individual days and 
7 multiple-day combinations

n   

Set automatic On/Off cycles; use manual override when needed

n   

Real-time 24/7 accuracy to the minute

n   

12-hour am/pm clock format

n   

Set up to 8 On/Off cycles per day

n   

On board LED power indicator

n   

LCD display shows ON and OFF status

n   

Memory backup with onboard battery 

n   

20 Amp resistive switching capability, maximum

n  

Choice of 6 voltages: 120VAC, 230VAC, 24VAC/VDC, 12VAC/VDC

n   

Clear protective cover included

n   

UL and CE approvals, RoHS compliant

BUTTON FUNCTIONS

FEATURES

SPECIFICATIONS

Dimensions  . . . . . . . . . . . . . . . .  in inches  23/8H x 23/8W x 13/8D  

in mm  60H x 60W x 37D

Supply voltage ranges   . . . .  100–130VAC,  200–250VAC, 

24VAC/VDC, 12VAC/VDC

Operating accuracy   . . . . . . . ±1 second/day at 20°C
Operating temperature  . . . -10°C to +55°C
Standards   . . . . . . . . . . . . . . . . .  UL, CE, RoHS, CUR E166259

619-1

   100–130VAC   

619-2

   200–250VAC     

619-3

   24VAC/VDC     

619-4

   12VAC/VDC     

619-BRKT

   Mounting  bracket  

619 TIMER OPTIONS

Press 

 RESET button to reset timer before using.

CLOCK:  Press/hold to set current time with Day, Hour, Min buttons. 

Press to commence program execution after setting.

TIMER:  Press to enter program mode, and to review up to 8 total 

programmed on/off cycles.  

DAY:  In Clock mode, sets the current day of the week.  

In Timer mode, selects the built-in program period desired.

HOUR: Sets the hour. 
MIN: Sets the minutes.
MANUAL: Press to select ON/AUTO/OFF mode indicator.
RESET:   Press to Cancel all settings. Recessed button next to 

℗ 

Depress with pencil or ballpoint pen.

ON:  Red LED indicator is lit when the internal relay is energized, 

closing the Common (3) to NO (5) terminal.

TYPICAL WIRING EXAMPLE