Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide IntelliComm Communication Center For use with the IntelliFlo and IntelliPro pumps ...

Page 2: ...less noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N 520700 Rev B September 26 2008 Technical Support Contact Pentair Technical Support Sanf...

Page 3: ...IntelliComm enclosure 2 Mounting the IntelliComm enclosure 2 Connecting AC power wires to the IntelliComm 3 IntelliComm system wiring 4 IntelliComm electrical specifications 4 Connecting the IntelliFlo communication cable 5 Connecting to IntelliComm 5 Wiring Diagrams 6 4 speeds using IntelliTouch auxiliary relays 6 2 speed using an IntelliTouch 2 speed relay 7 Connection to Sta Rite heater to set ...

Page 4: ...before servicing the pump Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pump Failure to do so could result in serious injury or death to serviceman pool users or others due to electric shock Important Notice This manual provides installation and operation instructions for the product Consult Pentair Water with an...

Page 5: ...valent in size to the circuit conductors supplying this equipment WARNING To reduce the risk of injury service should only be attempted by a qualified Pool Service Professional WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times CAUTION The IntelliFlo pump is for use with permanently installed pools and may also be used wi...

Page 6: ...necting AC wires to terminal 1 and 2 Connecting control input wires to IntelliComm page 4 Connecting control input wires to terminals 3 to 10 from source devices such as automation controllers or heaters Kit Contents IntelliComm Communication Center IntelliComm Installation Guide this manual Required communication cable 50 foot two wire RS 485 communication cable P N 350122 Used to communicate to ...

Page 7: ... The IntelliFlo VF and IntelliPro VF pump can be programmed to run at a specific US gallons per minute GPM for each external control input IntelliFloVF 15 130 GPM IntelliProVF 15 130 GPM Programming Pump Speeds RPM for IntelliFlo VS SVRS IntelliFlo VS3050 and IntelliPro VS3050 The IntelliFlo VS SVRS IntelliFlo VS3050 and IntelliPro VS3050 pump can be programmed to run at a specific speed RPM for e...

Page 8: ...m the pool edges Note For pump operating instructions see the pump s Installation and User s Guide Mounting the IntelliComm enclosure 1 Using a medium flat blade screwdriver loosen the two plastic screws on the front cover and open the front cover 2 Mount the enclosure on a flat surface such as a wall or post Mark each mounting screw hole location 3 Drill four inch 6 35 mm holes Install anchors if...

Page 9: ...he following Grounding is required The unit should be installed by a qualified service person and grounded To connect theAC power wires to IntelliComm 1 Use 12 14 AWG three conductor insulated wire for the main AC power connection Connect the main AC power wires to the IntelliCommAC terminals number 1 and 2 as shown below 2 Grounding Attach incoming GROUND wire to the ground terminal as shown belo...

Page 10: ...which can be actuated by either 15 to 240 VAC or 15 to 100 VDC from the source device automation controller heater heat pump etc There are four pump external control programs that can be enabled Note The IntelliComm will always be configured to communicate to pump address 1 IntelliComm system wiring table IntelliComm electrical specifications Power Requirements The IntelliComm draws less than 1 am...

Page 11: ...ntrol four IntelliFlo or IntelliPro external control programs The example uses four auxiliary relays in an IntelliTouch automation controller Auxiliary relays from other automation controllers would be wired similarly Wire the IntelliTouch relay contacts as shown The controller would then be configured so that each auxiliary relay energizes when a certain flow or speed is required 2 speed using an...

Page 12: ...lays 1 2 9 5 4 3 8 7 6 12 11 10 GND POWER PRGM 4 PRGM 3 PRGM 2 PRGM 1 RS485 RS485 IntelliComm IntelliFlo Drive GRN YEL 100 to 240 VAC Power Supply Aux 2 Relay Aux 1 Relay Aux 4 Relay Aux 3 Relay 115 VAC from circuit breaker 230 VAC Power to Pump Low Volt Comm Cable HOT NEUTRAL IntelliTouch Panel ...

Page 13: ...OWER PRGM 4 PRGM 3 PRGM 2 PRGM 1 RS485 RS485 IntelliComm IntelliFlo Drive GRN YEL 100 to 240 VAC Power Supply 2 Speed Relay Filter Pump Relay 230 VAC Power to Pump Low Volt Comm Cable 115 VAC from circuit breaker HOT NEUTRAL IntelliTouch Panel 2 speed using an IntelliTouch 2 speed relay ...

Page 14: ... 8 7 6 12 11 10 GND POWER PRGM 4 PRGM 3 PRGM 2 PRGM 1 RS485 RS485 IntelliComm IntelliFlo Drive GRN YEL 100 to 240 VAC Power Supply 230 VAC Power to Pump Low Volt Comm Cable Starite Heater Connection to Sta Rite heater to set pump flow or speed when heater is running ...

Page 15: ... during the term of the warranty then upon the consumer following the procedures set forth below Pentair Water will at its option repair or replace such item or part at its own cost and expense Pentair Water is not however responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service Department Also Pentair Water is no...

Page 16: ...P N 520700 Rev B 520700 ...