background image

IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS

Installation Guide

IntelliChlor

 Power Center

(For use with

IntelliChlor

 model IC20 and IC40)

Patents pending

Summary of Contents for C20

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide IntelliChlor Power Center For use with IntelliChlor model IC20 and IC40 Patents pending ...

Page 2: ...0 Trademarks and disclaimers IntelliChlor IntelliTouch EasyTouch and the Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Pentair Water Pool and Spa Inc disclaims proprietary interest in marks and names of others P N 520590 Rev...

Page 3: ...Support iii Introduction 1 Power Center Overview 1 IntelliChlor Models 1 Operating Instructions 2 Installation 2 Kit Contents 2 RequiredTools 2 SAFETY PRECAUTIONS 2 Installing the Power Center 3 Troubleshooting 5 Electrical Specifications and 110 VAC and 220 VAC Wiring 6 220 VAC Basic System Wiring 6 110 VAC Basic System Wiring 6 ...

Page 4: ...r water circulation A build up of flammable gases will result in hazardous conditions CAUTION When using IntelliChlor with an IntelliTouch system it is recommended to wire the IntelliChlor Power Center to the pump side of the relay located in the IntelliTouch Load Center This wiring method does not require a ground fault circuit interrupter GFCI to protect the circuit A green colored terminal or a...

Page 5: ...5 P M Phone 800 831 7133 Fax 919 566 8920 Moorpark California 8 A M to 5 P M Phone 800 831 7133 Fax 805 530 0194 Web sites visit www pentairpool com and www staritepool com 1 3 2 4 Declaration of Conformity We declare under our sole responsibility that the product identified in this declaration and to which this declaration relates are in conformity with the protection requirements of Council Dire...

Page 6: ...bottom of the enclosure for additional protection There are no other controls or lights on the outside of the Power Center A green power LED indicator is mounted on the inside main board When the Power Center is switched on the power LED is lit IntelliChlor Models The IntelliChlor salt chlorinator system models are PC 100 P N 520556 Power Center Kit IC 20 Cell P N 520554 Designed for pools up to 2...

Page 7: ...onnector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment The power supply must be interconnected with pool pump motor power source This insures the IntelliChlor chlorinator and pool pump will switch on and off together Grounding earth bonding is required The unit should be installed by a quali...

Page 8: ...er see the IntelliChlor User s Guide P N 520589 Mount the Power Center enclosure 1 Remove the screw securing the Power Center cover and remove the cover 2 Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location There are two 2 screw holes and a keyslot for the top and lower bracket 3 Drill six inch 6 35 mm holes Install anchors if necessar...

Page 9: ...The Power Center should be connected to the pump motor switch or automatic timer For system wiring information see page 6 7 Attach incoming GROUND wire to the ground lug inside the Power Center 8 Earth Bonding Grounding Connect the earth wire to the GROUND BONDING LUG located on the bottom of the Power Center enclosure Earth bonding is necessary to ensure personal safety and safety of equipment IM...

Page 10: ...b 24 hour 317 gm 24 Hour IntelliChlor Model IC40 Input 90 130 VAC 50 60 Hz 220 Watts 2 AMP or 220 240 VAC 50 60 Hz 220 Watts 1 AMP Output 22 39 VDC 6 AMPS maximum from the Power Center Chlorine 1 40 lb 24 Hour 635 gm 24 Hour IMPORTANT When using IntelliChlor with an IntelliTouch system it is recommended to wire the Power Center to the pump side of the relay located in the IntelliTouch Load Center ...

Page 11: ...6 IntelliChlor Power Center Installation Guide Notes ...

Page 12: ...ed by this warranty become evident during the term of the warranty then upon the consumer following the procedures set forth below Pentair Water will at its option repair or replace such item or part at its own cost and expense Pentair Water is not however responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service D...

Page 13: ...P N 520590 Rev C ...

Reviews: