background image

© 2014 Pentair Equipment Protection

PH 763 422 2211   

    

pentairprotect.com

89116261

Rev. A

P/N 89116262

 

Usage notes

For use on a flat surface of a type 4/12 enclosure

Failure to follow these instructions may lead to damage or injury. Comply with local and 
national safety requirements when working in hazardous locations.

 Before you start

The installation may be carried out by using either a circular hole saw or a hydraulic hole 
punch.

Tools required:

1.  Hydraulic punch or hole saw (95 mm - 95.5 mm (3-3/4 in.))  
2.  Drill
3.  Conedrill 

 

 

 

4.  Pozidrive screwdriver
5.  Center punch   

 

 

6.  6 mm (1/4 in.) drill bit
7.  3.6 mm (9/64 in.) drill bit

 Getting started

Unpack and check

When your Infrared Window arrives, carefully unpack  
the unit and check contents:

1.   IW4000 unit (1) 

 

 

2.   Fixing screws (4) 
3.   Drilling template (1)

IR Window

IW4000

STEP 

1

Reviews: