background image

perco.com                  linkedin.com/mwlite/company/perco                   export@perco.com                  +7 (812) 247-04-64

   

RTD-20 full height double rotor turnstile is a doubled version of RTD-16 full height rotor turnstile 

i.e. it features two passage lanes. This turnstile allows saving more than 25% of the passageway 

width compared with two RTD-16 turnstiles installed in a row.
Turnstile is available in two versions:

 

RTD-20.1 – with the motor drive of automatic resetting

 

RTD-20.2 – with the mechanical drive of resetting

RTD-20.1S and RTD-20.2S turnstiles are equipped with a stainless steel rotor.
Two RC-panels are included in the standard delivery set, one for each passage zone. Buttons 

orientation relative to the passage directions is to be set upon connecting the RC-panel to the 

RTD-20 Full height rotor turnstile

Application

RC-panel

turnstile.
It is recommended to install one turnstile based on a maximum 

working load of 20 persons/min. Turnstiles can be equipped with 

a matching gate and railings.

Each passage zone provides passage control in two directions, operating mode may be 

set independently for each passage direction of both passage zones. Supported operating 

modes:

 

passage denial in both directions

 

single passage in one direction and passage denial in the other direction

 

successive single passage in both directions

 

free passage in one direction and passage denial in the other direction

 

free passage in one direction and single passage in the other direction

 

free passage in both directions

 

lock-chamber mode (two-step mode with a pass-through verification, set during 

installation)

The product is a normally closed device. When de-energized, the rotor is locked in its home 

position.

Operating modes

+55

-40

22-30V

operating 

voltage

temperature 

range

40

persons/min

mechanical 

unlocking

2

passage 

direction

motor drive

210

 

W

W

power 

consumption

Summary of Contents for RTD-20

Page 1: ...It is recommended to install one turnstile based on a maximum working load of 20 persons min Turnstiles can be equipped with a matching gate and railings Each passage zone provides passage control in two directions operating mode may be set independently for each passage direction of both passage zones Supported operating modes passage denial in both directions single passage in one direction and ...

Page 2: ...pped with a stainless steel rotor two control modes pulse and potential possibility to connect an intrusion detector and a siren to the turnstile The turnstile with regard to resistance to environmental exposure complies with GOST 15150 69 category N2 operation outdoors The operation of the turnstile is allowed at ambient temperature from 40 C to 55 C and relative air humidity up to 98 at 25 C Top...

Page 3: ...TD 20 1 max 105 W Power consumption current for each turnstile RTD 20 2 30 W walkway downlights 10 W Throughput rate for each passage lane in the single passage mode 20 persons min in the free passage mode 30 persons min Overall dimensions without canopy 2480х1595х2303 mm with RTC 20 canopy 2485х1840х2558 mm Turnstile weight RTD 20 1 max 370 kg RTD 20 2 max 375 kg Width of each passage zone 630 mm...

Page 4: ...STOP UNLOCK B A5 1 A5 2 ACS 1 ACS 2 OUT A13 7 8 9 10 11 GND RS SOUND UNLOCK A STOP UNLOCK B 7 8 9 10 11 XP1 XP19 DIN RAIL 7 8 9 10 11 GND RS SOUND UNLOCK A STOP UNLOCK B 7 8 9 10 11 XP1 XP19 DIN RAIL 17 12V 17 LED A 1 RIDER A 1 ACS 1 1 2 1 2 7 20 21 22 23 24 COMMON PASS A PASS B READY DET OUT PASS A PASS B READY DETECTOR COMMON BLUE BLACK BLUE RED RED BLACK 31 32 33 34 35 36 25 26 27 28 29 30 NO A...

Page 5: ...cated on the guide barrier set 37 38 U1 U2 Connection of the walkway downlights power supply Operation algorithm Each passage zone can operate from the RC panel included in the delivery set WRC or ACS controller Operation is performed by applying a low level signal to unlock A Stop and Unlock B contacts relative to the GND contact Response to these signals depends on the control mode the user has ...

Page 6: ... allowed cable length of the RC panel ACS controller is 40 meters The maximum allowed cable length of the power supply depends on its cross section and must be for 1 5 mm cable 10 meters for 2 5 mm cable 20 meters Example of connection to the ACS Example of one passage zone connection to the ACS controller CT L04 2 XT6 XT7 XT2 XT1 XT5 S1 XT4 OUT1 OUT2 IN RC RS 485 TCP IP 12V NO1 С1 NС1 NO2 С2 NС2 ...

Page 7: ...on a less steady foundation it is recommended to apply reinforcing elements 500х500х500 mm or RF 20 foundation frame When using the foundation frame hole marking and anchors are not required in this case the turnstile mounting is more secure Hole marking cable duct for cable laying turnstile with security gate and railing section mounting layouts are shown in Figures 2 holes ø25x100 24 holes ø16x6...

Page 8: ...rnstile and WHD 16 security gate Flanges of RTD 20 guide barrier sections Flanges of WHD 16 security gate 4 holes ø16x60 Hole marking for mounting turnstile and MB 16 security gate HDF marking template is provided for easier marking It is recommended to place ACS readers on the guide barrier sets near the indication blocks Lock chamber mode is arranged during the installation the home position of ...

Page 9: ...made of galvanized sheet steel Frameworks 1 2 3 5 Mounting hardware set 1 Installation instruction 1 Overall dimensions length x width x height 2548х1536х65 mm Weight max 50 kg Mounting Assembled frame is installed on prepared foundation sized 2800х1700 mm and 200 250 mm deep is levelled with included in the delivery set pins and reinforcement wires Cable channels are to laid cable channel is allo...

Page 10: ...re similar to the requirements for the turnstile mounting The symmetry axes of the turnstile mounting holes are the same Flanges and holes for RTD 20 turnstile mounting 4 holes ø16x60 Symmetry axis of mounting holes for RTD 20 and RTC 20 Hole marking for canopy mounting Warranty The warranty period is 5 five years commencing from the date of sale unless otherwise determined in the delivery contrac...