Page 1: ...P N 5500433 10 Rev H Perle Cx 10GRT SFP Media Converter Modules Installation Guide C 10GRT SFP CM 10GRT SFP ...

Page 2: ...tems or third party MSA compatible modules See the Technical Specifications section in this guide for supported modules The C model media converters are the unmanaged modules and the CM models are the managed media converters For information on the management options of the CM models refer to the Perle MCR MGT User s Guide that came with your Perle Management Module All combination of modules with...

Page 3: ...le Installation Guide 3 Getting to know your C CM 10GRT Media Converter Your C CM 10GRT Media Converter package consists of the following items C CM 10GRT module with one transceiver port SFP SFP and one RJ 45 copper port This guide Front View ...

Page 4: ... most installations Refer to the Auto Config Jumper section for CM models These are the steps required to configure the Perle C CM 10GRT module 1 Set the DIP switch settings optional 2 Install the module into the chassis 3 Insert the appropriate SFP SFP into the transceiver port 4 Connect the fiber cable 5 Connect the RJ 45 copper cable DIP Switches ...

Page 5: ...If link is lost on one of the connections then the other link will be brought down by the media converter Standard In this mode the links can be brought up and down independently of each other A loss of link on either connection can occur without affecting the other fiber connection Fiber Fault Alert Switch 2 Switch Position Mode Up default Enabled Down Disabled Enabled If the media converter modu...

Page 6: ...B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1 Media Converter Module A loses fiber connection RX 2 Media Converter Module A notifies the remote Media Converter Module that there is a fault on the Link 3 Media Converter Module B detects loss of fiber link on receiver RX 4 Media Converter Module B turns off transmitter TX Cut through Rate converting Sw...

Page 7: ...converter module will be in Fiber loopback mode Disabled When disabled the media converter module will not be in Fiber loopback mode Copper Negotiation Switch 5 Switch Position Mode Up default Auto Down Manual Auto The media converter module will auto negotiate copper link parameters Manual The media converter module will use the link parameters as defined by Switches 6 and 7 Copper Duplex Switch ...

Page 8: ...ort will be set to Half Duplex mode Copper Speed Switch 7 Switch Position Mode Up default 100Mbps Down 10Mbps Note Switch 5 must be set to manual for this setting to take affect UP The copper port will be fixed at 100 Mbps Down The copper port will be fixed at 10 Mbps Note For 1000Mbps and 10G the copper link must be auto negotiated ...

Page 9: ... internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this configuration as its running configuration If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration SW When set to SW Switch the module will at power up read the settings of the DIP Switches and us...

Page 10: ...Perle C CM 10GRT SFP Media Converter Module Installation Guide 10 ...

Page 11: ...ire 1000 Mbps SGMII For the Managed CM 10GRT SFP the configuration must be set within the software Refer to the Perle MCR MGT User s Guide that came with your Perle Management Module The unmanaged model the C 10GRT SFP supports the SGMII via the jumper setup as shown below The SGMII jumper is located on the outer edge at the midpoint of the card P3 Jumper Pins 1 and 2 to select SGMII for port 1 ...

Page 12: ...the module is in normal operation mode Green blinking slowly The module is in test or loopback mode Red Solid Hardware error detected See PWR Red LED Errors Red Blinking quickly Error detected See LK1 LK Errors LK1 Port 1 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through Of...

Page 13: ...been taken down as a result of Smart Link Pass Through Off No copper link present LK1 LK Error Codes LK1 LK Meaning Off Off Incompatible SFP SFP On On Internal Error Off On Mismatch in Cut though mode On Off SFP SFP communication error PWR Red LED Errors LK1 LK Meaning Blinking Blinking Blinking one second on 3 seconds off the maximum specified operating temperature within the inserted module has ...

Page 14: ... to the chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the media converter module to the desired operating mode 4 Locate the top and bottom alignment guides inside the chassis 5 Using the module alignment guides gently slide the module into the slot until it becomes flush with the front of the chassis Light pressure may be needed to seat the module Do not force the module...

Page 15: ...Perle C CM 10GRT SFP Media Converter Module Installation Guide 15 ...

Page 16: ...Fiber Module 1 Locate appropriate fiber module and insert into opening 2 Ensure the SFP SFP module is properly seated 3 SFP module may be inserted before or after the media converter module is inserted into the chassis 4 Proceed with fiber cable connection Installing the Duplex Fiber Cable 1 Locate a 1000 10GBase X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fi...

Page 17: ...fiber cable from the SFP SFP to the other media converter switch fiber device Installing the Copper Cable 1 Locate 10 100 1000 10GBase T compliant copper cables with male RJ 45 connectors installed at both ends 2 Connect the RJ 45 cable between the Perle media converter module and the device Note The Perle Media Converter Module supports Auto MDIX which allows a straight through or cross over Ethe...

Page 18: ...e the C CM 10GRT will reduce the power to that module s The C CM 10GRT will continue to monitor the modules temperature until the temperature is below the maximum operating temperature and then the C CM 10GRTwill return the module s to normal operating mode Loopback Mode Perle C CM 10GRT media converter modules can be put into Loopback mode for diagnosis purposes A packet generator and analyzer mu...

Page 19: ...GBase T based on IEEE 802 3bz Pluggable Fiber Transceiver IEEE 802 3ae 10G Base R 10 Gigabit SFP slot support 10GBase R Standard SFP Power level 1 1 watt and level 2 1 5 watts as per SFP 8431 Operating Temperature 0 C 50 C 32 F 122 F Storage Temperature 25 C 70 C 13 F 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft ...

Page 20: ...rted 10 Gigabit Fiber pluggable transceivers IEEE 802 3as compliant 10GBase SR 10GBase LMR 10GBase LR 10GBase ER 10GBase ZR Supported 10 Gigabit Copper pluggable transceivers SFP Direct Attach Cable DAC Also known as Twinax 10GBase CU 10GSFP Cu 10GBase CX1 10GBase CR1 Note Passive and Active cable types are supported Supported Gigabit Fiber SFP s 1000Base SX 1000Base LX LH 1000Base EX 1000Base ZX ...

Page 21: ...s MM 50 125 microns or 62 5 125 microns SM 9 125 microns Copper Cable Requirements Category 6A for 10G speeds 5 5e used for speeds under 10G Straight through or Ethernet crossover Note Please refer the product page on the Perle website for the most up to date specifications http www perle com ...

Page 22: ...nsceiver port Ensure that the copper cabling RJ 45 meets Ethernet copper cabling requirements No connectivity Set all DIP switches to the Up position Loopback Mode The media converter module has the ability to be put into Loopback mode for diagnosis purposes A packet generator and analyzer must be used to generate and capture the packets in this mode ...

Page 23: ...ce at his her own expense EN 55032 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made via this...