background image

 
 

PAN16

 

Smart energy plug in switch

 

               

       

 

                                                                                           

 

 

 

 

 

Introduction

 

This  plug-in  ON/OFF  switch  PAN16  is  a  security  enabled  wireless  switch,  based  on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  connected  load  is  possible  with  other  manufacturer’s  wireless  Controller.  Each 
switch  is  designed  to  act  as  a  repeater.  Repeaters  will  re-transmit  the  RF  signal  to 
ensure  that  the  signal  is  received  by  its  intended  destination  by  routing  the  signal 
around obstacles and radio dead spots. Because PAN16 supports Security Command 
Class, it can learn with  Secured controller. Its functionality and supported command 
classes is identical when included as a secure and non-secure device.

 

 
This  plug-in  ON/OFF  switch  is  able  to  detect  instance  wattage  (3000W/230Vac) 
(13Ampere)  and  overload  current  (14.5A  with  resistive  load)  of  connected  lights  or 
appliances. When detecting overload state, the Switch will be disabled and its On/Off 
button  will  be  lockout  of  which  LED  will  flash  quickly.    However,  unplug  and 
re-connect the switch will reset its overload condition to normal status.

 

 
 
 

Warning: 

1.Plug out to disconnect from power supply; Do not plug in line.   

2. Do not exceed the max rating. 

Warnung: 

1.Trennen Sie das Gerät von der Stromzuführung. Verwenden Sie das Gerät nicht mit 

einem DIP Schalter.   

2. Achten Sie darauf, dass die maximale Spannung niemals überschritten wird. 

Warnung: 

für    zwischenstecker: 

nicht hintereinander stecken 

 

Specification

 

Rated Voltage

 

100V-240Vac 50Hz-60Hz 13A

 

Maximum Load (Ampere)

 

13A (Resistive load) 

 

PAN16-1; PAN16-2; PAN16-3

 

Maximum Load (Ampere)

 

10A (Resistive load) 

 

PAN16-4

 

(Switzerland)

 

Socket Type:

 

Germany type: PAN16-1 

France type: PAN16-2

 

UK type: PAN16-3

 

Switzerland type: PAN16-4

 

Range

 

Minimum 40 m in door 100m outdoor line of sight

 

Operating Temperature

 

0°C - 40°C

 

Frequency Range

 

868.40MHz & 869.85MHz for EU (PAN16-1/-2/-3/-4); 

 

RF Maximum Power

 

+5dBm

 

** Specifications are subject to change and improvement without notice.     

 

 

Troubleshooting

 

                                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working 
and LED off

 

1.

 

The Switch is not 
plugged into the 
electrical outlet 
properly

 

2.

 

The Switch break down

 

1.

 

Check power connections

 

2. Don’t open up the Switch and send it 

for repair.

 

The Switch LED 
illuminating, but cannot 

1.Check if the load 

plugged into the Switch 

1. Set the ON/OFF switch of the load 

attached to ON

 

Summary of Contents for PAN16

Page 1: ...h quickly However unplug and re connect the switch will reset its overload condition to normal status Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zw...

Page 2: ...d 13A Resistive load For Instruction to http www philio tech com Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows PAN16 1 German PAN16 2 French PAN16 3 U K Note Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the...

Page 3: ...n mode Remove 1 Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the ev...

Page 4: ...he Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Comman...

Page 5: ...power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 ...

Page 6: ...AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size ...

Page 7: ... 3 5 Restore switch state mode Whenever the AC power return from lost PAN16 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is...

Page 8: ...nt by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 6 Command Classes The Switch supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS...

Reviews: