background image

Storage  Electric
Water Heater

Water Heating

AWH1111
AWH1121
AWH1121H/90
AWH1122H/90

AWH1110
AWH1120
AWH1122
AWH1121B/90
AWH1122B/90

© 2019 AquaShield
All rights reserved.
The Philips trademark and the Philips Shield Emblem are registered trademarks 
of Koninklijke Philips N.V. used under license.
This product has been manufactured by and is sold under the responsibility of 

Hong Kong  

AquaShield Health Technology Company Limited and 

Hong Kong AquaShield Health 

Technology Company Limited is the warrantor in relation to this product.
Rev A AUG 19

www.philips.com/welcome

Register your product and learn more in the website link below:

User Manual   

1-10

11-21

Manual Pengguna

High

Low

Heating

Power

High

Low

Summary of Contents for AWH1110

Page 1: ...Koninklijke Philips N V used under license This product has been manufactured by and is sold under the responsibility of Hong Kong AquaShield Health Technology Company Limited and Hong Kong AquaShield Health Technology Company Limited is the warrantor in relation to this product Rev A AUG 19 www philips com welcome Register your product and learn more in the website link below User Manual 1 10 11 ...

Page 2: ...d on and off by the utility This appliance can be used by children aged from 8 years and above and persons with reduced physic sensory or mental capabilities or lack of experience and knowledge if they have been given supervision instruction concerning using of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance s...

Page 3: ...WH1122B 90 02 2 Operating procedures 3 Product features Ensure all the piping connection without leakage before turning on the electric power of the heater Make sure that the tank is fully filled up with water otherwise the heating elements will be damaged Turn on the main electrical power supply and then adjust the temperature knob clockwise for higher temperature and anti clockwise for lower tem...

Page 4: ...e shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Water may drip from the discharge pipe of the pressure relief device so please keep the pipe open to atmosphere The pressure relief device should be operated regularly to remove lime deposits and to ver...

Page 5: ...xed Water Valve s Regulation Handle Prefiler optional The model code of the prefilter is AWP9820 07 AWH1110 AWH1111 Diagram 5 Machine Body Hot Water Outlet Pipe Mono directional Security Valve Shower Tap Water Pipe Water Inlet Valve Mixed Water Valve Pressure leakage Pipe Hand rinsing Basin Connection Mouth For Pipe Machine Body Hot Water Outlet Pipe Cold Water Outlet Pipe Mono directional Securit...

Page 6: ...he connector with the earth connection The ground wire must be green yellow in colour and attached to the terminal marked by the symbol The heater must be connected to the electricity supply which is out of reach from the person using the shower All wiring must conform to local requirements If any doubts please consult a qualified electrician Note All plumbing must be connected before electrical c...

Page 7: ...llowing conditions 1 Damage by improper operation such as improper components connection improper installation deprived of manual use misoperation 2 Negligence and damage because of transportation or other accident 3 Maintenance and modification without approval 4 Other damage caused by force majeure such as natural disaster abnormal voltage etc 5 Damage caused by general use outside home e g indu...

Page 8: ...agar terhindar dari bahaya Perangkat pelepas tekanan harus dioperasikan secara teratur untuk menghilangkan endapan kapur dan untuk memverifikasi tidak tersumbat PERHATIAN Untuk menghindari bahaya karena pengaturan ulang pemutus termal yang tidak disengaja alat ini harus tidak dipasok melalui perangkat switching eksternal seperti timer atau terhubung ke sirkuit yang secara teratur dinyalakan dan di...

Page 9: ...an bahwa pemanas lebih dari 200mm dari permukaan tanah atau papan langit langit Ini akan meninggalkan ruang pemeliharaan bila perlu Metode perakitan Setelah memilih posisi pemasangan yang tepat gunakan baut yang menggembungkan untuk menahan papan gantung dengan kuat kemudian mengait pemanas air listrik Diagram 4 Semua bagian perpipaan adalah BSP 1 2 pita putih angin di sektor ulir pipa inlet ditan...

Page 10: ...dapat dipersingkat Jangan menyemprotkan bahan yang mudah terbakar seperti insektisida atau parfum di sekitar produk Simbol ini pada produk atau dalam kemasannya menunjukkan bahwa produk ini mungkin tidak diperlakukan sebagai limbah rumah tangga Sebagai gantinya itu harus dibawa ke tempat pengumpulan limbah yang sesuai untuk daur ulang peralatan listrik dan elektronik Dengan memastikan produk ini d...

Page 11: ...bung ke pasokan listrik yang jauh dari orang yang menggunakan pancuran Semua kabel harus sesuai dengan persyaratan lokal Jika ragu silakan berkonsultasi dengan teknisi listrik yang kompeten Catatan Semua sambungan pipa ledeng harus diselesaikan sebelum membuat sambungan listrik Isi tangki dengan air dan nyalakan keran untuk membiarkan air keluar dari tangki sampai semua udara dikeluarkan AWH1120 A...

Page 12: ...n dan modifikasi tanpa persetujuan 4 Kerusakan lain yang disebabkan oleh force majeure seperti bencana alam tegangan tidak normal dll 5 Kerusakan yang disebabkan oleh penggunaan umum di luar rumah mis Penggunaan industri dan komersial 6 Penuaan keausan yang disebabkan oleh operasi normal produk tanpa mempengaruhi operasi normal produk This statement serves as a publicity for free maintenance withi...