background image

Service Manual

Philips Domestic Appliances and Personal Care

Published by Philips Domestic Appliances and Personal Care 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

 Specialist 

Vacuum 

cleaner

FC 9104

/A
/B

PRODUCT INFORMATION

- Colour 

/A

  

Mint 

green

Version 

/B

  

2000 

logo

-  Maximum air displacement 

:  37 l/sec.

-  Maximum vacuum water column 

:  310 cm

-  Power consumption (IEC) 230 V 

:  1500 W

-  Duststorage capacity 

:  3 L

-  Type number dustbag 

:  FC 8021

-  Cord length (depends on version)  :  7 metres 
-  Filter system 

 

:  Paper dustbag

 

 

:  Exhaust HEPA air fi lter

 

 

:  Motor inlet fi lter 

-  Dimensions of cleaner 

:  460 x 315 x 270 mm

-  Dimensions of packaging 

:  595 x 395 x 295 mm

-  Net weight 

 

:  5.88 kg

-  Gross weight   

:  9.135 kg

OPTIONAL

-  FC 8021  

S-bags

- FC 8030 

AFS-fi lter

-  FC 8031 

HEPA Air Filter

-  FC 8034 

Upgrate kit Active Carbon Filter

-  HR 6988 

Turbo brush nozzle

-  HR 8040 

Polishing nozzle

SERVICE INFORMATION

-  Open the appliance, fi rst remove the exhaust fi lter grille 

(

item 20

), and then remove the 2 screws - 

C

 of the switch 

control panel (

item 15

).

-  Undo and remove the 9 screws - 

C

 in the upper housing 

(

item 8

).  You will require a screwdriver with a 14.5 cm-long 

shank for this. 

4322 277 00576
02/05

  Depending on the version screwdriver 9965 000 08332 for cross 

head or onwards 0234 screwdriver 4322 009 08490 for T15 can be 
used.

Item8

 Spare part is standard 

supplied without a hole, you must drill 
a hole 2mm dia, so the air can reach 
the sensor on the PCB via the 
pressure tube. 

 - 

Item 22

 Replace the HEPA fi lter as 

soon as the pilot light of the fi lterfull 
indicator goes on.

-  The component confi guration shown in the exploded view may 

differ in case of specifi c versions.  The components are 
distinguished by means of code numbers.

-  When the repair is fi nished, check whether all functions of the 

appliance work properly.

Item 4

, cotton dustbag, is used in countries in which paper 

dustbags are not available.

-  To disassemble the cord winder, use TORX screwdriver no.T15, 

which is one of a set consisting of T20; T15; T10; T9; T8; T7 and T6 
(code number 4822 395 50145).

-  If the reel half spring unit is replaced, shaft 

A

 must be lubricated 

with 

silicone grease

.  Do not apply any silicone grease to or spill 

any grease on terminals (

43

) or conductors (

42

).

Item 40

 is provided with a long cord-winder spring, but both long 

and short cords can be used in combination with this spring.
(L = 9.3 m)

-  Depending on the original cord, the spare cord must be shortened 

to the length of the original cord.

-  The cord winder spring must be tensioned to the maximum level 

and then be rewound approx. 1.5 turn 

Item 13

, air valve, opens to cool the motor if the air displacement 

is too low or if the airfl ow is blocked.

-  To adjust the telescopic tube (

item 59

) to the required length, push 

the adjustment collar in the direction of the arrow while sliding the 
top section of the telescopic tube into or out of the lower section.

-  If the function of the electronic control unit (

item 12

) is not 

required, the Triac must be short-circuited in the manner shown in 
the circuit diagram. 

-  When the vacuum cleaner is used to suck up fi ne dust the pores of 

the dustbag may become clogged, causing the passage of air 
through the dustbag to become obstructed. As a result, the 
dustbag-full indicator will indicate that the dustbag needs to be 
replaced, eventhough the dustbag is not full at all.

C

 2x

C

 9x

Ø 2mm