background image

S7980

Summary of Contents for S7980

Page 1: ...S7980 ...

Page 2: ......

Page 3: ...1 2 3 8 9 10 13 15 14 11 12 4 5 6 7 16 17 18 ...

Page 4: ...empty page before TOC ...

Page 5: ...English 6 简体中文 35 ...

Page 6: ...kincare advice tailored to you General description Fig 1 1 Protection cap for cleansing brush 2 Cleansing brush 3 Cleansing brush base 4 Shaving unit 5 On off button 6 Handle 7 Socket for small plug 8 SkinAnalyst sensor 9 Notification symbol 10 Shaving unit detector 11 Cleansing brush detector 12 Cleaning reminder 13 Bluetooth symbol 14 Travel lock symbol 15 Battery charge indicator 16 Pouch 17 Su...

Page 7: ...inAnalyst sensor can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of both appliances in a safe way and understand the hazards involved Children shall not play with the shaver Cleaning and user maintenance shall not be made by chil...

Page 8: ... agents or aggressive liquids such as petrol or acetone to clean the shaver Water may drip from the socket at the bottom of the shaver when you rinse it This is normal and not dangerous because all electronics are enclosed in a sealed power unit inside the shaver Do not use the supply unit in or near wall sockets that contain an electric air freshener to prevent irreparable damage to the supply un...

Page 9: ...complies with all shaver standards and regulations regarding exposure to electromagnetic fields General This shaver is waterproof It is suitable for use in the bath or shower and for cleaning under the tap For safety reasons the shaver can therefore only be used without cord The shaver is suitable for mains voltages ranging from 100 to 240 volts The supply unit transforms 100 240 volts to a safe l...

Page 10: ...n feature is activated Every time you switch on the shaver this feature automatically recognizes the attachment shaving unit cleansing brush that is attached to the shaver handle and adapts the settings accordingly Unpairing of your iPhone and the shaver deactivates this feature Manually select attachment Make sure your shaver is connected to your iPhone The SkinAnalyst app also offers the possibi...

Page 11: ...ou to clean the shaver Clean the shaver and the attachments after each use for optimal performance Bluetooth The shaver is equipped with Bluetooth 4 0 to connect your shaver to the app on your iPhone Bluetooth is automatically activated when you switch on the shaver for the first time You can only deactivate it by switching on the travel lock Travel lock You can lock the shaver when you are going ...

Page 12: ...l flashes and then goes out The shaver is now ready for use and Bluetooth is activated again Charging Battery charge indicator Charging takes approx 1 hour Quick charge When the battery is empty and you connect the shaver to the wall socket the battery charge indicator flashes quickly When the shaver contains enough energy for one shaving or cleansing session the battery charge indicator starts fl...

Page 13: ... is almost empty the battery charge indicator flashes orange When the battery is completely empty the battery charge indicator flashes orange quickly Charging Charging takes approx 1 hour Charge the shaver before first use and when the display indicates that the battery is almost empty Note You can charge the shaver after every use This will not harm the battery Charging with the supply unit 1 Mak...

Page 14: ...ng routine Note The app is available for iPhone 6 iPhone 6 Plus iPhone 6S and iPhone 6S Plus equipped with iOS9 or higher To create a secure and safe connection first the shaver and your iPhone need to be paired once 1 Download the SkinAnalyst app from the App store 2 Make sure Bluetooth on your iPhone is switched on S7920 3 Open the app on your iPhone 4 Follow the instructions in the app After yo...

Page 15: ...sion Note When you use the shaver keep your iPhone and shaver within transmission range no more than 5 meters from each other in the same room Using the shaver Using the SkinAnalyst sensor 1 Open the app before measuring your skin 1 2 2 If you have an iPhone case first remove the case from your iPhone 3 Pull the clamp of the SkinAnalyst sensor outwards and gently place your iPhone into the holder ...

Page 16: ...the sensor before and after skin measurement When you take a picture of the skin please position the sensor flat onto your skin so to ensure it can take a clear picture of your skin Connecting with the shaver 1 Make sure Bluetooth on your iPhone is switched on S7920 2 Open the app on your iPhone 3 When paired the shaver and the app connect automatically You can now start with your daily skincare r...

Page 17: ...er to benefit optimally from the treatments you have to synchronize your treatments regularly The shaver can store up to 15 shaves and or cleansing treatments so make sure you synchronize the shaver at least once after every 15 treatments As an extra reminder the notification symbol flashes every 9 treatments without a connection between the shaver and the app to tell you to connect with the app 1...

Page 18: ... Then press down the attachment to attach it to the shaver click Using the cleansing brush Use the rotating cleansing brush with your daily cleansing cream The cleansing brush removes oil and dirt contributing to a healthy and oil free skin We advise you to use it no more than twice a day It is recommended not to use the cleansing brush directly after shaving to prevent skin irritation For better ...

Page 19: ...t cleanse the sensitive area around your eyes 20 sec 7 After approx 15 20 seconds depending on the selected setting the shaver pulsates twice to indicate that you have to move the shaver to your other cheek Start cleansing this part of your face After approx 15 20 seconds move the shaver to your other cheek and start cleansing this part of your face 20 sec 8 After approx 15 20 seconds the shaver p...

Page 20: ...or oily Using the shaving unit Note This shaver can only be used without cord Skin adaptation period Your first shaves may not bring you the result you expect and your skin may even become slightly irritated This is normal Your skin and beard need time to adapt to any new shaving system We advise you to follow the advice provided by the app and shave regularly at least 3 times a week with this sha...

Page 21: ...nit under the tap to ensure that the shaving unit glides smoothly over your skin 4 Switch on the shaver 5 Move the shaving heads over your skin in circular movements to catch all hairs growing in different directions Make sure each shaving head is fully in contact with the skin Exert gentle pressure for a close comfortable shave Note Do not press too hard this can cause skin irritation Note Rinse ...

Page 22: ...ipped with iOS9 or higher follow the steps below 1 Remove pairing from the app open the app Go to the menu in the app Select App settings and press Remove pairing from app 2 Unpair the shaver press and hold the on off button on the handle for approx 10 seconds to remove the bond between shaver and app Note The unpairing of the shaver is successful when the Bluetooth and notification symbol flash s...

Page 23: ... shaving unit with a towel or tissue as this may damage the shaving heads 1 Switch on the shaver 2 Rinse the shaving unit under a warm tap 3 Switch off the shaver Pull the shaving head holder off the bottom part of the shaving unit 4 Rinse the hair chamber under the tap 5 Rinse the shaving head holder under a warm tap 6 Carefully shake off excess water and let the shaving head holder air dry compl...

Page 24: ...he shaver 2 Detach the brush head from the attachment holder 3 Clean the parts thoroughly with warm water and soap 4 Dry the cleansing brush with a towel Cleaning the SkinAnalyst sensor Caution Never clean the SkinAnalyst sensor under the tap as this may cause damage 1 Remove the jack plug of the SkinAnalyst sensor 2 Detach your iPhone from the SkinAnalyst sensor 24 English ...

Page 25: ...advise you to let the shaver and its attachments dry before you put the protection caps on the cleansing brush and SkinAnalyst sensor and store the shaver in the pouch Store the shaver in the pouch supplied Put the protection cap on the cleansing brush to protect it from dirt accumulation Put the protection cap on the SkinAnalyst sensor to protect it from dirt accumulation 25 English ...

Page 26: ...eplace damaged shaving heads immediately Always replace the shaving heads with original Philips shaving heads see Ordering accessories 1 Switch off the shaver 2 Pull the shaving head holder off the bottom part of the shaving unit 2 1 3 Turn the retaining rings anticlockwise and remove them Place them aside in a safe place 4 Remove the shaving heads from the shaving head holder Discard the used sha...

Page 27: ...s fixed 1 Note Hold the shaving head holder in your hand when you reinsert the shaving heads and reattach the retaining rings Do not place the shaving head holder on a surface as this may cause damage to the shaving heads 7 Attach the shaving head holder to the bottom part of the shaving unit click 8 To reset the replacement reminder press and hold the on off button for approx 7 seconds Replacing ...

Page 28: ...al household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment This product contains a built in rechargeable battery which shall not be disposed of with normal household waste Please take your product to an official collection point or a Philips service center to have a professional remove the rechargeable b...

Page 29: ...le tools to open the shaver Be careful the battery strips are sharp 1 Remove the screw in the back panel with a screwdriver Then remove the back panel 2 Bend the hooks aside and remove the power unit 3 Break the snap hooks and remove the front panel of the power unit 4 Take out the battery holder and cut the battery tags with a pair of cutting pliers 29 English ...

Page 30: ...quently asked questions or contact the Consumer Care Center in your country Problem Possible cause Solution I cannot connect the shaver to the app You have not downloaded the app Download the SkinAnalyst app The app is available for iPhone 6 iPhone 6 Plus iPhone 6S and iPhone 6S Plus equipped with iOS9 or higher Your shaver is not switched on Make sure the shaver is switched on You have not opened...

Page 31: ...nd advice based on your usage With the app you can set your shave settings The app also reminds you when you need to replace the shaving heads to clean the shaver etc I cannot change the shave settings cleansing brush settings on the shaver Make sure there is a good connection between the shaver and your iPhone You can select the attachment shaving unit cleansing brush on the shaver In the app you...

Page 32: ...roughly remove the shaving heads from the shaving head holder one by one see Replacing the shaving heads Then separate the cutter from its guard and rinse each matching set under the tap After rinsing place the cutter back into its corresponding guard Finally put the shaving heads back into the shaving head holder see Replacing the shaving heads The cleansing brush does not clean as well as it use...

Page 33: ...an only be used without cord Unplug the shaver and press the on off button to switch on the shaver The rechargeable battery is empty Recharge the battery The travel lock is activated Press the on off button for 3 seconds to deactivate the travel lock The shaving unit is soiled or damaged to such an extent that the motor cannot run Clean the shaving heads thoroughly or replace them Also see Hairs o...

Page 34: ...Analyst sensor Make sure that the cover case of your iPhone is detached the camera lens of your iPhone is clean the SkinAnalyst sensor is correctly attached to your iPhone Your phone did not recognize the SkinAnalyst sensor Make sure that your volume limit settings are reset to default settings go to Settings Music Volume limit slide to the max Water is leaking from the bottom of the shaver During...

Page 35: ...及洁面刷的设置 调整为适合您皮肤 的剃须和清洁模式 并提供您相关护肤建议 基本说明 图 1 1 洁面刷保护盖 2 洁面刷 3 洁面刷基座 4 剃毛刀头部件 5 开 关按钮 6 手柄 7 小插头插座 8 SkinAnalyst 皮肤检测仪 9 通知符号 10 剃须刀头部件探测器 11 洁面刷探测器 12 清洗提示 13 蓝牙 符号 14 旅行锁符号 15 电池充电指示灯 16 存储袋 17 电源部件 适配器 18 充电插头 请参考快速入门指南和应用程序 了解如何将 SkinAnalyst 皮肤检测仪与应用程序关联 以及 如何使用应用程序获取个性化护肤建议的说明 使用剃须刀和 SkinAnalyst 皮肤检测仪之前 请仔细阅 读本重要信息 并妥善保管以供日后参考 随附的附 件可能因产品而异 35 简体中文 ...

Page 36: ...检测仪可以由 8 岁及 以上年龄的儿童以及肢体不健全 感官或精神上有 障碍或缺乏相关经验和知识的人士使用 但前提是 有人对他们使用这些产品进行监督或指导 以确保 他们安全使用 并且让他们明白相关的危害 切勿 让儿童玩弄剃须刀 不要让儿童在无人监督的情况 下对本产品进行清洁和保养 在自来水龙头下清洗剃须刀之前 务必拔掉其电源 插头 使用前 请务必检查剃须刀和 SkinAnalyst 皮肤检 测仪 请勿使用损坏的设备 否则可能造成人身伤 害 请务必用原装型号更换损坏的部件 切勿拆开剃须刀更换充电电池 警告 切勿使用温度高于 80 C 的热水冲洗剃须刀 切勿在水龙头下冲洗 SkinAnalyst 皮肤检测仪 警告符号注释 禁止在打开的水龙头下进行清洗 36 简体中文 ...

Page 37: ... 封闭在剃须刀内部的密封电源部件中 请勿在包含电动空气清新器的墙壁插座上或其周围 使用电源部件 以免电源部件受到不可修复的损 坏 您的 iPhone 应远离水和潮湿的环境 蓝牙剃须刀的短波射频信号可能会影响其他电子和 医疗设备的工作 请勿在医疗机构 飞机舱 加油站 以及靠近自动 门 自动火灾报警器或其他自动控制设备的场所使 用本剃须刀 请在禁止蓝牙的场所关闭蓝牙 请将本剃须刀与心脏起搏器及其他医疗设备之间保 持至少 20 厘米的距离 无线电波可能会影响心脏 起搏器及其他医疗设备的工作 电磁场 EMF 这款飞利浦剃须刀符合所有有关暴露于电磁场的剃 须刀标准和法规 概述 该剃须刀具有防水性能 适合在沐浴或淋浴时使 用 也可以放在水龙头下清洗 出于安全原因 该 剃须刀在使用时不能连接电线 37 简体中文 ...

Page 38: ...应用程序中提供重要建议 时 此符号会亮起 请转到应用程序以查看此建议 它会提醒您在打开本剃须刀电源之前拔掉剃须刀插头 并对其进行清洁以获得出色性能 另外 它还会提醒 您每两年更换一次剃须刀头 或每三个月更换一次洁面 刷 附件检测功能 在 iPhone 与本剃须刀配对后 附件检测功能将被激 活 每次打开本剃须刀电源时 此功能都会自动识别 安装到本剃须刀手柄上的附件 剃须刀头部件 洁面 刷 并相应地调整设置 如果解除 iPhone 和本剃须 刀的配对 则将禁用此功能 手动选择附件 确保您的剃须刀已连接到 iPhone 您还可以通过 SkinAnalyst 应用程序激活或禁用附件检测功能 您可 以前往 我的个人资料 然后进入 我的剃须刀 并 关闭自动附件检测功能 然后 您可以通过开启剃须 刀并按住开关按钮一秒钟 手动选择洁面刷附件 1 sec 38 简体中文 ...

Page 39: ...安装 到手柄上 洁面刷探测器 洁面刷探测器会亮起 表示已检测到洁面刷 清洗提示 关闭剃须刀时 清洗提示符号闪烁 提醒您需要清洁剃 须刀 为获得出色性能 请在每次使用后都清洁本剃 须刀和附件 蓝牙 本剃须刀配备了蓝牙 4 0 可用于将该剃须刀连接到 iPhone 上的应用程序 首次启动剃须刀时 即可自动 激活蓝牙 只能通过启动旅行锁来解除蓝牙 旅行锁 您可以在携带剃须刀旅行之前将其锁住 旅行锁可防 止剃须刀被意外打开 旅行锁还会禁用蓝牙 启用旅行锁 39 简体中文 ...

Page 40: ... 然后熄灭 本剃须刀现在可供使 用 蓝牙被重新激活 充电 电池充电指示灯 充电约需 1 小时 快速充电 电池电量耗尽后 当您将本剃须刀连接到 电源插座时 电池充电指示灯会快速闪烁 本剃须刀 包含的电量足够完成一轮剃须或清洁时 电池充电指示 灯开始缓慢闪烁 如果本剃须刀继续充电 电池充电指示灯会缓慢闪烁 直至电池充满电 电池已完全充满 电池充满电后 电池充电指示灯将呈蓝色持续亮起 注意 本剃须刀只能在不接电源的情况下使用 注意 电池充满电后 显示屏会在 30 分钟后自动关 闭 如果在充电期间按开 关按钮 则通知符号会呈蓝 色亮起 提醒您需要断开本剃须刀与电源插座的连接 40 简体中文 ...

Page 41: ... 样做将对电池有益无害 使用电源部件充电 1 确保剃须刀已关闭 1 2 2 将小插头插入剃须刀 然后将电源部件插入壁式插 座 3 充电之后 从壁式插座上拔下电源部件 并从剃须 刀上拔下小插头 使用准备 将本剃须刀和 iPhone 进行配对 我们为此剃须刀提供了一个特殊的应用程序 您可以 从 App Store 下载 SkinAnalyst 应用程序 通过使用该 应用程序 可以对护肤和剃须程序进行个性化设置 根据您的皮肤 剃须方法和当地的气候条件等 应用程 序会为您提供专业的建议 以支持您的日常护肤和剃须 程序 注意 该应用程序适用于安装有 iOS9 或更高版本的 iPhone 6 iPhone 6 Plus iPhone 6S 和 iPhone 6S Plus 41 简体中文 ...

Page 42: ...在填写完皮肤评估 后 应用程序会要求您将 iPhone 和本剃须刀进行配 对 5 打开剃须刀 蓝牙将被自动激活 6 在应用程序中 将出现弹出消息 按 配对 在 iPhone 和本剃须刀成功配对后 蓝牙符号将短暂闪 烁 然后熄灭 如果蓝牙未被激活 请参阅 故障 处理方法 7 在本剃须刀与应用程序进行配对后 该剃须刀将自 动选择合适的个人设置 具体视卡入的附件而定 在剃须或洁面期间 您可以打开应用程序 查看当 前使用的设置 以及剃须或洁面的时长 注意 使用本剃须刀时 确保 iPhone 和剃须刀在 传输范围内 在同一个房间内 彼此之间的距离不 超过 5 米 使用剃须刀 使用 SkinAnalyst 皮肤检测仪 1 测量皮肤前要打开应用程序 42 简体中文 ...

Page 43: ...hone 6S Plus 4 将 SkinAnalyst 皮肤检测仪的插头插入 iPhone 中 5 从 SkinAnalyst 皮肤检测仪上卸下保护盖 注意 上述说明也会显示在应用程序中 仅当卸下 iPhone 的手机壳时 SkinAnalyst 皮肤检 测仪才工作 6 按照应用程序中的说明测量皮肤 注意 测量期间 始终将 SkinAnalyst 皮肤检测仪 置于皮肤上 以免闪入您的眼睛 在皮肤测量前后 请勿直视该皮肤检测仪 在拍摄皮肤照片时 请将该皮肤检测仪平放在皮肤 上 以便确保可以拍摄到清晰的皮肤照片 与剃须刀建立连接 1 确保 iPhone 上的蓝牙已打开 S7920 2 打开 iPhone 上的应用程序 3 成功配对后 剃须刀和应用程序将自动连接 现 在 您便可以开始执行日常护肤程序了 注意 要想充分利用应用程序功能 应确保网络连 接良好 4 同步本剃须刀和应用程序 请参见 同...

Page 44: ...一下开 关按钮 2 要关闭剃须刀 请按一下开 关按钮 同步剃须和洁面护理数据 为了从护理中获得最大受益 您需要定期同步护理数 据 本剃须刀最多可以存储 15 次剃须和 或洁面护理 数据 因此 请确保每进行 15 次护理后至少同步一次 本剃须刀 作为额外的提醒 如果本剃须刀未连接应 用程序 则每进行 9 次护理后 通知符号会闪烁一 次 告知您要连接应用程序 1 打开应用程序 确保您贴近本剃须刀 2 应用程序会自动与本剃须刀相连 并同步您的最新 剃须或洁面护理数据 使用附件 注意 请先将洁面刷安装到洁面刷基座上 然后再安 装到本剃须刀上 拆卸或安装附件 1 确保剃须刀已关闭 44 简体中文 ...

Page 45: ...须刀上 可听到 咔哒 一 声 使用洁面刷 将旋转洁面刷与日常洁面产品一起使用 洁面刷可去 除油脂和污垢 焕发健康无油脂的肌肤 建议每天使 用本产品不超过 2 次 建议不要在剃须后直接使用洁 面刷 以免皮肤过敏 为获得更佳的剃须效果 请在 剃须前使用洁面刷 警告 请不要在受伤或发炎的皮肤或伤口上使用本剃 须刀 1 将洁面刷安装到本剃须刀上 听到 咔哒 一 声 2 用水湿润洁面刷 注意 切勿在洁面刷干燥的情况下使用本剃须刀 否则可能会刺激皮肤 3 用水润湿面部 并将洁面乳涂抹到脸上 4 将洁面刷置于面颊上 5 打开剃须刀 45 简体中文 ...

Page 46: ...大约 15 20 秒钟后 本剃须刀将震动两下 表示您 需要将本剃须刀移至前额 开始清洁这部分面部皮 肤 轻轻将刷头从左向右移动 剃须刀会在完成整 个面部程序后自动停止 注意 建议您不要过度清洁 任何部位的清洁时间 不要超过 15 20 秒钟 9 护理后 洗脸并擦干 现在您可以进行日常面部护 肤的下一步了 10 使用后 请清洁洁面刷 洁面刷设置 应用程序还可个性化定制清洁设置 转至 使用跟踪 器 并更改洁面刷设置 您可以根据个人的洁面需要 调整设置 并从四种设置中进行选择 敏感 干燥 正常或油性 使用剃须刀头部件 注意 本剃须刀只能在不接电源的情况下使用 皮肤适应期 前几次剃须可能不会带给您预期效果 并且您的皮肤可 能会受到轻度刺激 这是正常的 您的皮肤和胡须需 要时间适应任何新的剃须系统 我们建议您按照应用程 序提供的建议操作 并在 4 周的时间内定期 至少每 46 简体中文 ...

Page 47: ...以获取舒适贴 面的剃须感受 注意 不要用力按压剃须刀 这样做可能会导致皮 肤疼痛 3 使用后应立即清洁剃须刀 湿剃 您也可以先用剃须泡沫或剃须啫喱将脸弄湿 然后再用 此剃须刀进行剃须 要用剃须泡沫或剃须啫喱剃须 请按照下面的步骤执行 操作 1 用水润湿皮肤 2 在皮肤上涂抹剃须泡沫或剃须啫喱 3 在水龙头下冲洗一下剃须刀头部件 确保剃须刀头 部件可以在您的皮肤上顺畅滑动 4 打开剃须刀 5 让剃须刀头在您的皮肤上作迂回运动 以刮剃向不 同方向生长的所有须发 轻轻按压 以获取舒适贴 面的剃须感受 注意 不要用力按压剃须刀 这样做可能会导致皮 肤受刺激 47 简体中文 ...

Page 48: ...ne 之间的连接 要删除此连接 例如 如果您使用安装有 iOS9 或更高 版本操作系统的新 iPhone 6 iPhone 6 Plus iPhone 6S 或 iPhone 6S Plus 请按照以下步骤操作 1 从应用程序中删除配对 打开应用程序 转到应 用程序中的菜单 选择 应用程序设置 并按 从应用程序中删除配对 2 解除剃须刀配对 按住手柄上的开 关按钮约 10 秒 钟 以解除剃须刀与应用程序之间的联系 注意 如果蓝牙和通知符号同时闪烁 约 4 秒 钟 则表示成功解除了本剃须刀的配对 3 解除 iPhone 的配对 选择 设置 通用 蓝牙 按 i 选择设备 按 忘记设备 清洁和保养 如果本剃须刀和应用程序已配对 则作为额外的提醒 在每次剃须后 本剃须刀上的洁面提示会亮起 告知您 清洁剃须刀 在水龙头下冲洗剃须刀头部件 每次剃须后清洁剃须刀头部件 以获得出色的性能 48 简体中文 ...

Page 49: ...使用热水要当心 切记先检查水温是否太高 以防烫 手 不要用毛巾或纸巾擦拭剃须刀头部件 因为这样可能会 损坏剃须刀头 1 打开剃须刀 2 用温水冲洗剃须刀头部件 3 关闭剃须刀 将剃须刀头支架从剃须刀头部件的底 部抽离 4 在水龙头下冲洗胡茬储藏室 5 用温水冲洗剃须刀头支架 6 小心地甩掉多余水分并彻底晾干剃须刀头支架 7 将剃须刀头支架安装到剃须刀头部件的底部 可听 到 咔哒 一声 49 简体中文 ...

Page 50: ... 2 从附件基座上卸下刷头 3 用温水和肥皂彻底清洗部件 4 用毛巾擦干洁面刷 清洁 SkinAnalyst 皮肤检测仪 警告 切勿在水龙头下清洗 SkinAnalyst 皮肤检测仪 否则可能会造成损坏 1 拔下 SkinAnalyst 皮肤检测仪的插头 2 从 SkinAnalyst 皮肤检测仪上卸下 iPhone 3 使用蘸过酒精的棉签 轻轻地清洁 SkinAnalyst 皮 肤检测仪中的两个镜面 4 使用干净的棉签擦干这两个镜面 50 简体中文 ...

Page 51: ...SkinAnalyst 皮肤检测仪上 将剃 须刀存放在收纳袋中 将剃须刀存放在随附的软袋中 将保护盖放在洁面刷上 以防产品积聚灰尘 将保护盖放在 SkinAnalyst 皮肤检测仪上 以防产 品积聚灰尘 更换 更换剃须刀头 2yrs 在应当更换剃须刀头时 通知符号也会亮起 以作为额 外的提示 应用程序中也提供此建议 为获得更好剃须效果 建议每两年更换一次剃须刀头 立即更换损坏的剃须刀头 务必使用原装飞利浦剃须 刀头 请参见 订购配件 进行更换 1 关闭剃须刀 51 简体中文 ...

Page 52: ...2 将剃须刀头支架从剃须刀头部件的底部抽离 2 1 3 逆时针旋转固定环并将其取下 将其存放在安全的 地方 4 从剃须刀头支架上卸下剃须刀头 立即丢弃用过的剃须刀头 以免与新的剃须刀头混 淆 5 将新的剃须刀头装到剃须刀头支架中 注意 确保剃须刀头两侧的槽口正好卡入剃须刀头 支架上的凸起部位 2 1 6 将固定环放回剃须刀头上 然后顺时针旋转以重新 安装固定环 52 简体中文 ...

Page 53: ...头支架安装到剃须刀头部件的底部 可听 到 咔哒 一声 8 要重置更换提醒 请按住开 关按钮约 7 秒钟 更换洁面刷 每 3 个月应更换一次刷头 或当刷毛在更短时间内出 现变形或损坏时更换 在应当更换刷头时 通知符号 也会亮起 以作为额外的提示 应用程序中也提供此建 议 订购配件 要购买附件或备件 请访问 www shop philips com service 或联系您的飞利浦经销 商 您还可以联系所在国家 地区的飞利浦客户服务中 心 请参阅全球保修卡了解详细联系信息 可选配以下附件和备件 SH70 飞利浦剃须刀头 HQ110 飞利浦剃须刀头清洁喷雾剂 RQ560 RQ563 飞利浦洁面刷 HQ8505 电源部件 注意 配件可用性可能因国家 地区而异 53 简体中文 ...

Page 54: ... Ġ ȕ PBDE PCB s מ ŪǗɢ ذ X O O O O O Electrical contact pins ǗˈਝǦ X O O O O O Power plug Ǘ۷ Ǽ X O O O O O ǕȪϜ SJ T 11364Ā ܪ ǭৠ 뺯 O ȪФ ĈҴˀΙć ˌɫǨĈߴΙࠒնġĀߒʔߴćGB T 26572 ܪ ǭĀՄʔđ ŘĪ뺯 X ȪФ ĈҴˀΙψɺć ˌɫĀԚĂߴΙࠒնġĀߒʔɸŜGB T 26572 ܪ ǭĀՄʔđ 뺯 该表格中所显示的 有害物质 在产品正常使用情 况下不会对人身和环境产生任何伤害 该表格中所显示的 有害物质 及其存在的部件向 消费者和回收处理从业者提供相关物质的存在信 息 有助于产品废弃时的妥善处理 拆下充电电池 在废弃器具前 必须将电池从器具中取出 卸下 电池之前 请确保剃须刀与电源断开连接并且电 池电量已耗尽 当您使用工具打开剃须刀时 请采取...

Page 55: ...向外掰 取出电源部件 3 脱开安全钩 取下电源部件的前面板 4 用一把钢丝钳剪下电池带 保修和支持 如需信息或支持 请访问 www philips com support 或 阅读国际保修卡 故障处理方法 本章归纳了使用本剃须刀 SkinAnalyst 皮肤检测仪及 其附件时最常见的一些问题 如果您无法根据以下信 息解决问题 请访问 www philips com support 查阅常 见问题列表 或联系您所在国家 地区的客户服务中 心 55 简体中文 ...

Page 56: ... 6S Plus 未打开剃须刀电源 确保剃须刀已开启 尚未打开应用程序 确保打开应用程序 iPhone 找不到本剃须 刀 本剃须刀适用于安装有 iOS9 或更高版本操作 系统的 iPhone 6 iPhone 6 Plus iPhone 6S 和 iPhone 6S Plus 蓝牙未打开 确保本剃须刀和 iPhone 上的蓝牙已启 用 剃须刀未充电 确保本剃须刀已充电 我想在没有应用程序的 情况下使用本剃须刀 即使没有应用程序 您 也可以使用本剃须刀 但是 仅当应用程序与 本剃须刀结合使用时 应用程序才能根据您的 使用情况提供提示和建 议 您可以通过应用 程序设置剃须设置 应用程序还会在需要更 换剃须刀头和清洁剃须 刀等时候提醒您 56 简体中文 ...

Page 57: ... 剃须刀的剃须效果没有 以前好 剃须刀头已损坏或磨 损 更换剃须刀头 请参见 更换剃须刀头 毛发或污垢堵塞了剃须 刀头 对剃须刀头进行常规或 彻底清洁 要彻底清洁剃须刀头 请将剃须刀头从剃须刀 头支架上逐一 请参见 更换剃须刀头 卸下 然后 分离刀片和网 罩 并在水龙头下冲洗 每个刀片和网罩套装 冲洗后 将刀片放回对 应的网罩中 最后 将剃须刀头装回到剃须 刀头支架 请参见 更换 剃须刀头 中 洁面刷的清洁效果没有 以前好 洁面刷已损坏或磨损 更换洁面刷 请参见 更 换洁面刷 剃须刀检测不到正确的 附件 附件受到严重污染或损 坏 尝试清洁附件 请参见 清洁和保养 如果问 题依然存在 请通过应 用程序关闭检测功能 并手动选择该附件 方 法是在打开本剃须刀电 源时 按下开 关按钮 一秒钟 57 简体中文 ...

Page 58: ...彻底清洁剃须刀头或将 其更换 有关如何彻 底清洗剃须刀头的详细 说明 另请参阅 毛发 或污垢堵塞了剃须刀 头 剃须刀会在我选择不同 的刷头程序时关闭电 源 在洁面期间 不能更改 刷头程序 在选择不同的刷头程序 前 请关闭剃须刀电 源 在皮肤测量期间 应用 程序出现错误 未将 SkinAnalyst 传感 器平放在皮肤上 将 SkinAnalyst 传感器 平放在皮肤上 未将 SkinAnalyst 传感 器的插头正确地插入手 机 从手机上拔下 SkinAnalyst 传感器的 插头 然后将插头重新 插入手机 手机无法识别 SkinAnalyst 皮肤检测 仪 确保满足以下条件 已卸下iPhone机 套 壳 iPhone 的摄像镜头 洁净 已将 SkinAnalyst 皮肤检测仪正确地 连接到 iPhone 58 简体中文 ...

Page 59: ...常现象 而且没 有危险 因为所有电子 元件都封闭在剃须刀内 部的密封电源部件中 产品 飞利浦电动剃须刀 型号 S7980 额定电压 220V 额定频率 50Hz 额定输入功率 9 W 产地 荷兰 生产日期 请见产品本体 CMIIT ID 2017DP0589 SRRC申请单位 飞利浦 中国 投资有限公司 制造商 飞利浦电子香港有限公司 香港新界沙田香港科学园科技道东五号 经销单位 飞利浦 中国 投资有限公司 上海市静安区灵石路718号A1幢 全国顾客服务热线 4008 800 008 本产品根据国标 GB4706 1 2005 GB4706 9 2008 信部无 2002 353号制造 保留备用 发行日期 13 02 2017 59 简体中文 ...

Page 60: ......

Page 61: ......

Page 62: ......

Page 63: ...Empty page before back cover ...

Page 64: ... 2018 Koninklijke Philips N V All rights reserved 保留所有权利 4222 002 5991 4 16 2 2018 75 循环再造纸 75 recycled paper 75 papier recyclé ...