background image

Tel:

 +44 (0)1274 657 088   

Fax:

 +44 (0)1274 657 087   

Web:

 www.phoebeled.com

Images are for information only. Phoebe LED shall not be held liable for improper operation of the luminaire in circumstances where procedures and 

specifications have not been followed correctly.

THANK YOU for buying this PHOEBE LED product. 

To help ensure this luminaire gives complete satisfaction please only use it according to the 

following instructions, and then pass the instructions to the appropriate person for retention and future reference.

This instruction sheet is relevant to Phoebe LED Atlas-Mini LED Slimline Floodlights with part codes:

 

6416, 6423, 6430, 6447, 6454, 6461, 7581, 7598, 10314, 10321, 10338, 10345, 10352, 10369, 10376, 10383

Specifications:

Part Codes 

PIR sensor

fitted

Wattage

Voltage

Power 

Factor

IP Rating

IK Rating

Useful 

Lumens

Total

Lumens

Cable

Insulation

Ambient

 

Operating Temp

Black

White

7581

10314

No

10W

240V 

50/60Hz

>0.5

IP66

IK08

760lm

900lm

VDE H05RN-F

 

3G 1.0mm

Class I

-20°C to 40°C

6416

10338

No

20W

>0.5

1450lm

1600lm

6430

10352

No

30W

>0.9

2200lm

2400lm

6454

10376

No

50W

>0.9

3850lm

4200lm

7598

10321

Yes

10W

>0.5

760lm

900lm

VDE H05RN-F

 

4G 1.0mm

6423

10345

Yes

20W

>0.5

1450lm

1600lm

6447

10369

Yes

30W

>0.9

2200lm

2400lm

6461

10383

Yes

50W

>0.9

3850lm

4200lm

Dimensions:

Part Codes 

Wattage Width (W) Height (H) Depth (D) Depth inc. PIR (D2)

Black

White

7581

10314

10W

140mm

126mm

30mm

-

6416

10338

20W

201mm

166mm

34mm

-

6430

10352

30W

201mm

166mm

34mm

-

6454

10376

50W

298mm

226mm

40mm

-

7598

10321

10W

140mm

188mm

30mm

51mm

6423

10345

20W

201mm

216mm

34mm

51mm

6447

10369

30W

201mm

216mm

34mm

51mm

6461

10383

50W

298mm

272mm

40mm

55mm

IP66

IK08

BEFORE YOU START

PLEASE READ ALL THE 

INSTRUCTIONS CAREFULLY

ONLY ONCE INSTALLATION 

IS COMPLETE

Turn power 

back on at 

the mains

CIRCUIT TESTING

For high voltage circuit insulation 

testing disconnect mains input 

supply first

 

(Do not circuit test using a Megger)

Turn power 

off at the 

mains

PRIOR TO INSTALLATION

Warning

1.  Installation only to be carried out by a qualified electrician

2. Please ensure surface is suitable and capable of holding the lamp weight

3.  Do not operate if product is damaged

4.  Suitable for use outdoors IP66 rating

5.  This product is not suitable for fire rated installations

TI

M

E

Settings are on the

 

Rear of the PIR

Angle Adjustment:

1.  Angle floodlight to desired angle
2.  Tighten socket head screw to prevent unit from moving

Wiring Instructions:

1.  

Installation only to be carried out by a qualified electrician

2.  240V mains cable connection should be made with a 

suitable IP65 junction box

3.  Connect power lead to 240V mains electricity in 

accordance with current wiring regulations

(see wiring diograms overleaf)

Fitting:

1.  Mark drill points and drill fixing holes and hole for power 

cable (if required)

2.  Align luminaire and fix in place surface using bolts/

fixtures suitable for chosen surface, the angled bracket 

allows access to mounting points without the need to 

disassemble the fitting

LUX

S

EN

S

Operation Instructions (for PIR Sensor Only):

• The monitoring angle is up to 120°

•  Depending on the angle of the sensor the monitoring range 

has a maximum detection distance of 12m

•  Lighting time length can be adjusted from 10 seconds (±3 sec) 

turning clockwise up to 8 minutes (±2 min) after detection

•  Dusk-til-Dawn detection can be manually adjusted by turning

 

the LUX dial to allow for light levels/time of year

 

(for daylight sensor testing turn fully to sun position)

• 

 Sensitivity of the motion sensor can be changed by adjusting the SENS dial effective range 5m to 12m

H

W

D

H

W

D

D2

To 240V 

Mains

PIR tilt 

& Twist

Socket 

Head 

Screw

Reviews: