Tel:
+44 (0)1274 657 088
Fax:
+44 (0)1274 657 087
Web:
www.phoebeled.com
Images are for information only. Phoebe LED shall not be held liable for improper operation of the luminaire in circumstances where procedures and
specifications have not been followed correctly.
THANK YOU for buying this PHOEBE LED product.
To help ensure this luminaire gives complete satisfaction please only use it according to the
following instructions, and then pass the instructions to the appropriate person for retention and future reference.
This instruction sheet is relevant to Phoebe LED Atlas-Mini LED Slimline Floodlights with part codes:
6416, 6423, 6430, 6447, 6454, 6461, 7581, 7598, 10314, 10321, 10338, 10345, 10352, 10369, 10376, 10383
Specifications:
Part Codes
PIR sensor
fitted
Wattage
Voltage
Power
Factor
IP Rating
IK Rating
Useful
Lumens
Total
Lumens
Cable
Insulation
Ambient
Operating Temp
Black
White
7581
10314
No
10W
240V
50/60Hz
>0.5
IP66
IK08
760lm
900lm
VDE H05RN-F
3G 1.0mm
Class I
-20°C to 40°C
6416
10338
No
20W
>0.5
1450lm
1600lm
6430
10352
No
30W
>0.9
2200lm
2400lm
6454
10376
No
50W
>0.9
3850lm
4200lm
7598
10321
Yes
10W
>0.5
760lm
900lm
VDE H05RN-F
4G 1.0mm
6423
10345
Yes
20W
>0.5
1450lm
1600lm
6447
10369
Yes
30W
>0.9
2200lm
2400lm
6461
10383
Yes
50W
>0.9
3850lm
4200lm
Dimensions:
Part Codes
Wattage Width (W) Height (H) Depth (D) Depth inc. PIR (D2)
Black
White
7581
10314
10W
140mm
126mm
30mm
-
6416
10338
20W
201mm
166mm
34mm
-
6430
10352
30W
201mm
166mm
34mm
-
6454
10376
50W
298mm
226mm
40mm
-
7598
10321
10W
140mm
188mm
30mm
51mm
6423
10345
20W
201mm
216mm
34mm
51mm
6447
10369
30W
201mm
216mm
34mm
51mm
6461
10383
50W
298mm
272mm
40mm
55mm
IP66
IK08
BEFORE YOU START
PLEASE READ ALL THE
INSTRUCTIONS CAREFULLY
ONLY ONCE INSTALLATION
IS COMPLETE
Turn power
back on at
the mains
CIRCUIT TESTING
For high voltage circuit insulation
testing disconnect mains input
supply first
(Do not circuit test using a Megger)
Turn power
off at the
mains
PRIOR TO INSTALLATION
Warning
1. Installation only to be carried out by a qualified electrician
2. Please ensure surface is suitable and capable of holding the lamp weight
3. Do not operate if product is damaged
4. Suitable for use outdoors IP66 rating
5. This product is not suitable for fire rated installations
TI
M
E
Settings are on the
Rear of the PIR
Angle Adjustment:
1. Angle floodlight to desired angle
2. Tighten socket head screw to prevent unit from moving
Wiring Instructions:
1.
Installation only to be carried out by a qualified electrician
2. 240V mains cable connection should be made with a
suitable IP65 junction box
3. Connect power lead to 240V mains electricity in
accordance with current wiring regulations
(see wiring diograms overleaf)
Fitting:
1. Mark drill points and drill fixing holes and hole for power
cable (if required)
2. Align luminaire and fix in place surface using bolts/
fixtures suitable for chosen surface, the angled bracket
allows access to mounting points without the need to
disassemble the fitting
LUX
S
EN
S
Operation Instructions (for PIR Sensor Only):
• The monitoring angle is up to 120°
• Depending on the angle of the sensor the monitoring range
has a maximum detection distance of 12m
• Lighting time length can be adjusted from 10 seconds (±3 sec)
turning clockwise up to 8 minutes (±2 min) after detection
• Dusk-til-Dawn detection can be manually adjusted by turning
the LUX dial to allow for light levels/time of year
(for daylight sensor testing turn fully to sun position)
•
Sensitivity of the motion sensor can be changed by adjusting the SENS dial effective range 5m to 12m
H
W
D
H
W
D
D2
To 240V
Mains
PIR tilt
& Twist
Socket
Head
Screw