Page 1: ...Web Panels with TFT Display User manual UM EN WEB PANELS ...

Page 2: ...al Web Panels with TFT Display 2014 07 01 Designation Revision Order No UM EN WEB PANELS 02 This user manual is valid for Designation Order No WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 2913632 2913645 2700307 2700309 2700934 2700935 ...

Page 3: ...ve the purpose of technical progress The receipt of technical documentation in particular user documentation does not consti tute any further duty on the part of Phoenix Contact to furnish information on modifications to products and or technical documentation You are responsible to verify the suitability and intended use of the products in your specific application in particular with regard to ob...

Page 4: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T PHOENIX CONTACT ...

Page 5: ... View Mounting Depth 22 2 3 Connecting the Device 28 2 3 1 Supply Voltage 28 2 3 2 Grounding 29 2 4 Switching On 30 2 4 1 Loading Procedure on Windows CE Operating System 30 3 Control and Display Elements 43 3 1 Touchscreen 43 3 2 Display 43 4 Interfaces of the Device 45 4 1 Standard Interfaces 45 4 1 1 Ethernet X5 46 4 1 2 USB X9 X10 47 5 Maintenance and Servicing 49 5 1 Front Panel 49 5 2 Fuse 4...

Page 6: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 6 PHOENIX CONTACT 8361_en_02 6 7 WP 15T 58 ...

Page 7: ...ntion rules and regulations that apply to the operating site Installation and operation must only be carried out by qualified and trained personnel This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER This indicates a hazardous situation which if not avoided will result...

Page 8: ...influence the EMC behavior 1 4 Target Group The use of products described in this manual is oriented exclusively to Qualified electricians or persons instructed by them who are familiar with applicable standards and other regulations regarding electrical engineering and in particular the relevant safety concepts Qualified application programmers and software engineers who are familiar with the saf...

Page 9: ...kets into the appropriate openings figure 1 and pull the brack ets downwards until they lock in place 2 3 Fasten the device into position using the threaded pins 3 NOTICE Damage When installing the device leave a gap of at least 30 mm 1 181 around the device to ensure sufficient air circulation NOTICE Damage When the operating device is installed horizontally please note that additional sources of...

Page 10: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 10 PHOENIX CONTACT 8361_en_02 2 2 1 Front Panel Dimensions 2 2 1 1 WP 04T Figure 2 2 WP 04T ...

Page 11: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 11 2 2 1 2 WP 06T Figure 2 3 WP 06T ...

Page 12: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 12 PHOENIX CONTACT 8361_en_02 2 2 1 3 WP 07T WS Figure 2 4 WP 07T WS ...

Page 13: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 13 2 2 1 4 WP 09T WS Figure 2 5 WP 09T WS ...

Page 14: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 14 PHOENIX CONTACT 8361_en_02 2 2 1 5 WP 10T Figure 2 6 WP 10T ...

Page 15: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 15 2 2 1 6 WP 15T Figure 2 7 WP 15T ...

Page 16: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 16 PHOENIX CONTACT 8361_en_02 2 2 2 Mounting Cutout 2 2 2 1 WP 04T Figure 2 8 WP 04T A Mounting Cutout B Front Panel ...

Page 17: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 17 2 2 2 2 WP 06T Figure 2 9 WP 06T A Mounting Cutout B Front Panel ...

Page 18: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 18 PHOENIX CONTACT 8361_en_02 2 2 2 3 WP 07T WS Figure 2 10 WP 07T WS A Mounting Cutout B Front Panel ...

Page 19: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 19 2 2 2 4 WP 09T WS Figure 2 11 WP 09T WS A Mounting Cutout B Front Panel ...

Page 20: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 20 PHOENIX CONTACT 8361_en_02 2 2 2 5 WP 10T Figure 2 12 WP 10T A Mounting Cutout B Front Panel ...

Page 21: ...Installation and Commissioning 8361_en_02 PHOENIX CONTACT 21 2 2 2 6 WP 15T Figure 2 13 WP 15T A Mounting Cutout B Front Panel ...

Page 22: ...09T WS WP 10T WP 15T 22 PHOENIX CONTACT 8361_en_02 2 2 3 Side View Mounting Depth 2 2 3 1 WP 04T Figure 2 14 WP 04T 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 23: ...tallation and Commissioning 8361_en_02 PHOENIX CONTACT 23 2 2 3 2 WP 06T Figure 2 15 WP 06T 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 24: ...WP 07T WS WP 09T WS WP 10T WP 15T 24 PHOENIX CONTACT 8361_en_02 2 2 3 3 WP 07T WS Figure 2 16 WP 07T WS 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 25: ...lation and Commissioning 8361_en_02 PHOENIX CONTACT 25 2 2 3 4 WP 09T WS Figure 2 17 WP 09T WS 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 26: ...6T WP 07T WS WP 09T WS WP 10T WP 15T 26 PHOENIX CONTACT 8361_en_02 2 2 3 5 WP 10T Figure 2 18 WP 10T 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 27: ...tallation and Commissioning 8361_en_02 PHOENIX CONTACT 27 2 2 3 6 WP 15T Figure 2 19 WP 15T 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal 5 Front Panel ...

Page 28: ...g out The device has reverse polarity protection In case of wrong polarity the device will not operate This is a protection class I device For safe operation safety extra low voltage SELV in accordance with DIN EN 61131 must be used for the supply voltage Table 2 1 Pin assignment supply voltage Pin Designation Function 1 Noiseless ground functional earth ground FE 2 0 V Supply voltage 0 V GND 3 24...

Page 29: ... depending on the type of device with a slip on sleeve or a ring cable lug 3 Plug the slip on sleeve on the flat tab or mount the ring cable lug with the nut to the threaded bolt Figure 2 21 Noiseless ground protective ground NOTICE Damage A separate copper conductor must always be provided for the grounding The conductor must have a minimum cross section of 1 5 mm 16 AWG and must be kept as short...

Page 30: ...e with the buttons The operating panel has three operating modes Normal no button pressed Settings button Settings was pressed Setup Main button Settings followed by OS Settings was pressed 2 4 1 1 Normal Mode The defined start URL is opened Figure 2 22 Display after startup Settings http 192 168 0 2 entry html 0 The operating device is compatible to Phoenix Contact controllers of type ILC 1xx ILC...

Page 31: ...ing device after the de fined time in seconds Settings Info Page The following informations are displayed Device designation serial number Microbrowser version operating system version plat form and resolution of the display with color depth Settings Restore Test Settings OS Settings Quit Info Page Restore Save Device Name Info Page Serial Nr MicroBrowser Ver OS Platform Display WP 04T 20090721005...

Page 32: ...tings is cancelled and the start URL is called up 2 4 1 3 Setup Main Mode If you press the button Settings followed by OS Settings during the startup phase the Setup Main mode starts Figure 2 24 Setup Main Update Figure 2 25 Update Update Copy USB Stick Figure 2 26 Copy USB Stick Update Touch Screen Registry Network Settings Start Batchfile Exit Settings Setup Main Some settings are password prote...

Page 33: ...em settings If the backup directory of the USB stick contains a corresponding log file these settings can be restored This is possible only when using identical device types Update Update Image If the image subdirectory on the USB stick contains a nb0 file this file is used to perform the image update There must be only one nb0 file located in this directory otherwise the update does not start Upd...

Page 34: ...gure 2 29 Backlight Properties A screen saver can be activated after the defined time minutes It is possible to adjust the screen saver graphic by replacing the file Screensaver bmp in the internal memory The graphic is replaced at the start up of the operating device automatically when a USB stick containing the file Screensaver bmp in the Screensaver directory is present The brightness of the ba...

Page 35: ...d protected Network Settings Figure 2 31 Network Settings Network Settings TCP IP Info Figure 2 32 TCP IP Info The following informations are displayed MAC address IP address Subnet mask address Server 5 myserver myhost local SNTP Settings Interval minutes OK Cancel Time Synchronization SNTP Client No SNTP SNTP Server TCP IP Info Fix Settings Home Network Settings DHCP Device Name FTP Settings All...

Page 36: ...his entry is able to be password protected Contents of the IPSetting ini file IPCONFIG IPAddress 172 016 042 150 SubnetMask 255 255 255 000 Network Settings Fix Settings Gateway Figure 2 34 Gateway The system automatically deselects DHCP and optionally enters the settings from the IPSetting ini file of the USB stick This file must exist in the root directory of the USB stick If no USB stick is con...

Page 37: ...P and optionally enters the settings from the IPSetting ini file of the USB stick This file must exist in the root directory of the USB stick If no USB stick is connected the information is read from the registry This entry is able to be password protected Contents of the IPSetting ini file IPCONFIG PrimaryWINS 172 016 042 150 SecondaryWINS 172 016 042 151 Network Settings DHCP Figure 2 37 DHCP Yo...

Page 38: ...S box Network Settings FTP Settings Delete a user Figure 2 39 Delete a user You may enter the user name you like to delete This entry is able to be password protected Network Settings Device Name Figure 2 40 Device Name You can define a device name with up to 14 characters Via a FTP connection you can ac cess the device with the device name instead of the IP address This entry is able to be passwo...

Page 39: ...ny action the value is not accepted Depending on the display type different values can be influenced Selection of color depth for TFT displays This entry is able to be password protected Settings Date Time Figure 2 43 Date Time Display Type Contrast Brightness STN mono X STN color X X TFT X Contrast Date Time Password Home Settings Information Printer Contrast 15 OK Apply Brightness 15 Cancel 8 bp...

Page 40: ... able to be password protected Settings Printer Figure 2 45 Printer The print function depends on the application program on the operating device Connection of a printer is possible via the network and the USB interface The operating system sup ports PCL3 compatible printers This entry is able to be password protected Table 2 2 Already used printer models Model HP OfficeJet 6000 HP OfficeJet Pro 8...

Page 41: ...entry is automatically stored in the registry Settings Printer Network Print Network Server Login Figure 2 48 Network Server Login You can save login data for network printing This enables auto login when printing without manual input at the operating device Enter a user name password and domain This entry is automatically stored in the registry Page Settings OK Cancel Letter A4 Page Settings Netw...

Page 42: ...ct ID Image version Built version Built date Size of flash Size of SRAM Size of PLC Visu RAM Bus clock speed Start Batchfile The project bat file in the FlashDrv directory starts if available Information SNR 1023456789 Image_Grafikpanel_EP9307_CE5 00 _V1 18 Built Aug 27 2007 14 00 00 Flash Size 16 MB SRAM Size 512 kB PLC VISU RAM 0 460 kB Busclock 49 MHz Click OK to go back to main ...

Page 43: ...p objects such as pens or fingernails can lead to irreparable damages of the touch screen Exclusively therefore use the fingertips or the aids indicated in the tech nical data for the operation DANGER Toxic If the display is damaged avoid touching swallowing or breathing in the liquids or gases which may leak out DANGER Corrosive If the display is damaged avoid touching swallowing or breathing in ...

Page 44: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 44 PHOENIX CONTACT 8361_en_02 ...

Page 45: ...ENIX CONTACT 45 4 Interfaces of the Device 4 1 Standard Interfaces Figure 4 1 Rear view Ethernet 1 Female Connector X5 Ethernet 2 Female Connector X9 X10 USB Host Type A 3 Threaded Bolt for Protective Grounding 4 Connector X1 Supply Voltage ...

Page 46: ...f the Ethernet interface Pin Designation Function 1 Tx Transmitted Data Positive Polarity 2 Tx Transmitted Data Negative Polarity 3 Rx Received Data Positive Polarity 4 n c Not Connected 5 n c Not Connected 6 Rx Received Data Negative Polarity 7 n c Not Connected 8 n c Not Connected NOTICE Use a twisted pair cable of category 5 CAT 5 The maximum cable length is 100 m 328 084 feet See the IEEE 802 ...

Page 47: ...sing input devices not suitable for industrial use e g keyboard mouse may decrease safety of operation This includes input devices intended for home and office use For the specification of a suitable cable please refer to the Universal Serial Bus Specifi cation Rev 2 0 NOTICE Use industrial suited USB cables with a length of maximally 2 5 m 8 202 feet ...

Page 48: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 48 PHOENIX CONTACT 8361_en_02 ...

Page 49: ...ns 5 2 Fuse A semiconductor fuse is used to protect the device Once the fuse has been tripped the de vice must be disconnected from the supply voltage to allow the semiconductor fuse to re generate At an ambient temperature of 20 C 68 F the regeneration takes approximately 20 seconds The higher the ambient temperature the longer the regeneration takes NOTICE Damage The semiconductor fuse cannot be...

Page 50: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 50 PHOENIX CONTACT 8361_en_02 ...

Page 51: ...n 1 5 Mbit s Max 12 Mbit s Max output current 100 mA per output Central Processing Unit Central processing unit RISC ARM9 Clock frequency 200 MHz Memory Flash 32 MByte SDRAM 64 MByte Connection Method RJ45 female connector USB female connector A MINI COMBICON male connector MC 1 5 3 STF 3 5 Art No 1847068 COMBICON male connector MSTB 2 5 3 STF BD Art No 1896381 Environmental Conditions Temperature...

Page 52: ...IN EN 61000 6 4 Equipment requirements DIN EN 61131 2 Storage and transportation DIN EN 61131 2 Power supply DIN EN 61131 2 Electromagnetic compatibility 2004 108 EG Degrees of protection DIN EN 60529 Impact load shocks DIN EN 60068 2 27 Sinusoidal vibrations DIN EN 60068 2 6 NOTICE Radio Interference This is a class A device This device may cause radio interference in residential areas In this ca...

Page 53: ...8 V Maximum voltage 30 V Power consumption typical at 24 V 0 3 A Power consumption maximum 0 4 A Connected load 7 2 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 90 x 120 x 5 3 543 x 4 724 x 0 197 Seal ...

Page 54: ...Minimum voltage 18 V Maximum voltage 30 V Power consumption typical at 24 V 0 4 A Power consumption maximum 0 6 A Connected load 9 6 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 126 x 168 x 5 4 961 x 6...

Page 55: ...8 V Maximum voltage 30 V Power consumption typical at 24 V 0 5 A Power consumption maximum 0 7 A Connected load 12 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 147 x 203 x 5 5 787 x 7 992 x 0 197 Seal ...

Page 56: ...nimum voltage 18 V Maximum voltage 30 V Power consumption typical at 24 V 0 6 A Power consumption maximum 0 8 A Connected load 14 4 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 172 x 260 x 5 6 772 x 10...

Page 57: ... Maximum voltage 30 V Power consumption typical at 24 V 0 6 A Power consumption maximum 0 8 A Connected load 14 4 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 220 x 295 x 5 8 661 x 11 614 x 0 196 Seal ...

Page 58: ...imum voltage 18 V Maximum voltage 30 V Power consumption typical at 24 V 1 0 A Power consumption maximum 1 2 A Connected load 24 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 329 x 400 x 5 12 953 x 15 7...

Page 59: ...USB 47 L Loading procedure on windows CE operating system 30 M Maintenance 49 Mounting 9 N Normal mode 30 P Pin assignment Ethernet 46 R Rear view Ethernet 45 S Safety notes 7 Servicing 49 Setup Main operating mode 32 Standards 52 Supply Voltage 28 Switching on 30 Symbols 7 T Target group 8 Technical data 51 WP 04T 53 WP 06T 54 WP 07T WS 55 WP 09T WS 56 WP 10T 57 WP 15T 58 Touchscreen 43 U Unpacki...

Page 60: ...WP 04T WP 06T WP 07T WS WP 09T WS WP 10T WP 15T 60 PHOENIX CONTACT 8361_en_02 ...