Owner’s Manual  —  Phoenix R200 LGR Dehumidifier

Installation, Operation & Service Instructions

1

www.UsePhoenix.com • sales@UsePhoenix.com

Toll-Free 1-800-533-7533

Read and Save These Instructions

 The Phoenix R200 LGR Dehumidifier

Patented Bypass Technology - 

Increased performance over a 

wide temperature range.

R-410A Refrigerant - 

The Phoenix R200 comes charged  

with R-410A refrigerant.

Capacity - 

The Phoenix R200 removes 125 pints per day at 

AHAM (80°F/60%RH).

Energy Efficiency - 

Draws only 8.3 amps and removes 5.2 

pints/kWh.

Compact Design - 

Smaller, 20”x20”x33.5”, and only 105 lbs.

Motorized Impeller - 

325 CFM; Faster drying and superior 

static pressure for ducting.

More Grain Depression - 

Drier air from an LGR finishes jobs 

quicker versus a conventional refrigerant dehumidifier.

Focused Airflow - 

Patent focused outlet directs air downward 

across the wet surface.

Multiple Ducting Options - 

12” intake, 10” exhaust

.

Plastic Housing - 

Rugged roto-molded housing.

Solid State Controls - 

Easy to read and operate.

Protected Condensate Hose - 

Located under the top cover.

 

Quick connect, cannot catch or be damaged on obstruction

s.

Telescoping Handle - 

A heavy-duty retractable handle for ease 

of transport and reduces space for storage and stacking.

Recessed 12” Wheels - 

Allows greater maneuverability on the 

job site and efficient storage. Rolls over obstacles with ease.

Pleated Media Air Filter - 

A 12”x12”x1” MERV-11 filter is 

standard.

Stacking/Nesting - 

Reduces space for ease of stacking and 

storage.

Specifications subject to change without notice.

TS-391 

09/13

4201 Lien Rd. • Madison, WI 53704

Phoenix R200
Part No. 4027000
Patent  7,246,503 

     7,281,389 

  

7,540,166

 

The Phoenix R200 is a compact, energy efficient LGR 
dehumidifier that removes 125 pints per day (AHAM) while 
drawing only 8.3 amps of electricity. The R200 outperforms 
larger competitive dehumidifiers by removing more water, 
providing larger grain depression and consuming less power. 
The proven LGR design is surrounded by a durable roto-
molded high impact plastic to create a dehumidifier that is 
smaller and lighter than competitive units. 

In addition to the performance benefits and compact size, 
the R200 has patented bypass technology, increased 
airflow, multiple ducting options,  and a pleated media 
filter. The R200 is the latest member of the Phoenix line of 
LGR dehumidifiers; the most effective and versatile drying 
devices made.

BYPASS

Patented

Summary of Contents for R200

Page 1: ...obstructions Telescoping Handle A heavy duty retractable handle for ease of transport and reduces space for storage and stacking Recessed 12 Wheels Allows greater maneuverability on the job site and efficient storage Rolls over obstacles with ease Pleated Media Air Filter A 12 x12 x1 MERV 11 filter is standard Stacking Nesting Reduces space for ease of stacking and storage Specifications subject t...

Page 2: ... Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of sealed refrigeration system parts Dimensions Unit Shipping Width 20 21 Height 33 5 35 25 Depth 20 21 Weight 105 lbs 115 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a large water tight container and turn on To decrease drying times make sure all windows ...

Page 3: ... plastic exhaust tabs If the R200 is located in the unaffected area the intake can be ducted with 12 flex duct see accessories in section 6 Attach the flex duct to the top cover by hooking the spiral wire under the four tabs Tape the duct to the top cover for a complete seal 3 5 Defrost Cycle If the low side refrigerant temperature drops below the defrost set point due to excessive frost formation...

Page 4: ... IMPORTANT DO NOT operate the unit without the filter or with a less effective filter as the heat exchanger and coils inside the unit could become clogged and require disassembly to clean 4 2 Storage There are two issues to consider when the Phoenix R200 is stored between uses and both pertain to the water trapped in the unit damage caused by freezing or biological growth The effect of the trapped...

Page 5: ...WER button ON 1 Defective control board 2 Loose connection in internal wiring Some dehumidification air mover runs continuously but compressor only runs sporadically 1 Unit is in defrost cycle DEFROST light on 2 Defrost thermistor defective or loose 3 Loose connection in compressor circuit 4 Defective compressor overload 5 Defective compressor 6 Defective relay 7 Upper housing is not sealed to low...

Page 6: ...7 Reassemble thermistor and dehumidifier using the above procedure in reverse Figure 8 Picture of the float safety switch 5 5 Condensate Pump The internal condensate pump removes water that collects in the reservoir To replace the condensate pump 1 Unplug the unit 2 Remove the front housing 3 Unplug the pump wires from the wire harness 4 Remove the condensate hose and the one screw attaching the p...

Page 7: ...BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 9 Wiring diagram 7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 6 Options Accessories 4024750 Intake Flex Duct 12 x 25 Metallize Polyester 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 7 Wiring Diagram ...

Page 8: ...26986 13 Cord 1 4032315 14 Control Board 1 4026763 15 Capacitor Compressor 45 μF 1 4033032 05 16 Capacitor Impeller 15 μF 1 4033031 07 17 Thermistor 1 4031279 18 Handle lever 1 4026350 Description Qty Part No Compressor 1 4029190 Evaporator Coil 1 4026985 Condenser Coil 1 4026983 Accumulator 1 4028297 Condensate Pump 1 4034582 01 Description Qty Part No Float Safety Switch 1 4034374 Impeller Air M...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R200 Dehumidifier part is repaired...