background image

 

HOT TUB OWNER’S MANUAL 

MODELS:

 

PINNACLE PLUS – PN 631, PN 741, PN 743, 

                 PN 850, PN 855 

                LUXURY –   LX 4000, DX 5000, LX 5000, 

                                     LX 8000, LX 9000, LX 11000 

 

 

6101 45

th

 St. N. 

St. Petersburg, FL 33714 

800.304.9684 

www.PinnacleSpas.com

 

Part Number 7636 

SKUs: (1001-1011) 

Revised 5/11 

Summary of Contents for LUXURY DX 5000

Page 1: ...ELS PINNACLE PLUS PN 631 PN 741 PN 743 PN 850 PN 855 LUXURY LX 4000 DX 5000 LX 5000 LX 8000 LX 9000 LX 11000 6101 45th St N St Petersburg FL 33714 800 304 9684 www PinnacleSpas com Part Number 7636 SK...

Page 2: ...___________________ Address __________________________ Telephone __________________________ Hot Tub Date Delivered __________________________ Model __________________________ Color ___________________...

Page 3: ...the limited warranty card within 30 days of purchase to ensure you understand what you are entitled to in terms of service If you have any questions you can call our customer care center at 800 304 9...

Page 4: ...al provides feel free to visit our Web site at www PinnacleSpas com or call our customer care center at 800 304 9684 WARNING This manual was written to ensure the proper use and installation of your h...

Page 5: ...l The GFCI must be tested before each spa use DANGERS RISK OF ACCIDENTAL DROWNING Extreme caution must be exercised to prevent unauthorized access by children To avoid accidents ensure that children c...

Page 6: ...dication should consult a physician before using a spa hot tub since some medication may include drowsiness while other medication may affect heart rate blood pressure and circulation Do not connect a...

Page 7: ...a hot tub should never exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for young children senio...

Page 8: ...prior to using your hot tub each time to ensure it operates properly Any electrical devices near your hot tub must be GFCI protected and out of reach from inside the hot tub Keep all breakables away f...

Page 9: ...solid flat surface designed to properly support its weight For external installations a 4 inch 10 cm thick cement pad suffices See page 8 for conduit entry locations for your model hot tub 5 For inte...

Page 10: ...m 13 33 cm LX 9000 1003 20 51 cm 13 33 cm LX 11000 1002 22 56 cm 12 30 cm PN 631 1011 12 30 5 cm 9 23 cm PN 741 1007 29 73 5 cm 15 38 cm PN 743 1009 27 68 5 cm 13 33 cm PN 850 1008 25 63 5 cm 13 33 cm...

Page 11: ...ns for export models Failure to do so will cause equipment damage and will not be covered under your warranty All hot tubs must be over current protected with a built in GFCI or RCD for export models...

Page 12: ...essible to a person in the hot tub Earthed appliances must be permanently connected to fixed wiring Parts incorporating electrical components except remote control devices must be located or fixed so...

Page 13: ...Page 11 For HELP call 800 304 9684...

Page 14: ...4 9684 Figure 4 European 1x32A Wiring Diagram All wiring is 3x4mm2 solid copper See wire size chart on page 9 Note Make sure that the DIP switches in the hot tub Pack are properly set for 50Hz operati...

Page 15: ...04 9684 Figure 5 European 2x16A Wiring Diagram All wiring is 5x4mm2 solid copper See wire size chart on page 9 Note Make sure that the DIP switches in the hot tub Pack are properly set for 50Hz operat...

Page 16: ...Page 14 For HELP call 800 304 9684 Figure 7 Domestic Wiring Diagram for LX 8000 LX 9000 and LX 11000 Models Single phase 240V with VS510SZ Control Pack See wire size chart on page 9...

Page 17: ...0 304 9684 Figure 8 Board Diagram for LX 8000 LX 9000 and LX 11000 Models Single phase 240V Domestic version Figure 9 Panel Button Positions for LX 8000 LX 9000 and LX 11000 Models Single phase 240V D...

Page 18: ...Page 16 For HELP call 800 304 9684...

Page 19: ...Page 17 For HELP call 800 304 9684 Figure 10 Domestic Wiring Diagram for LX 4000 and LX DX 5000 Models Single phase 240V with VS515Z Control Pack See wire size chart on Pg 9...

Page 20: ...Page 18 For HELP call 800 304 9684 Figure 11 Board Diagram for LX 4000 and LX DX 5000 Models Single phase 240V Domestic version...

Page 21: ...Page 19 For HELP call 800 304 9684 EXPORT WIRING ALL MODELS LX 4000 LX 11000 Figure 12 Export Wiring Diagram for all models for GS510SZ Control Pack See wire size chart on Pg 9...

Page 22: ...Page 20 For HELP call 800 304 9684 Figure 13 Board Diagram for all models Export version for GS510SZ Control Pack Figure 14 Panel Button Positions for all models Export version...

Page 23: ...our customer care center at 800 304 9684 For best results read each step in its entirety before proceeding Caution Running the hot tub pump dry without water running through it can cause IMMEDIATE dam...

Page 24: ...ge to unions and gaskets which will not be covered under warranty Figure 17 Unions Tight 6 Check that the unions on all pumps are tight 7 Clean out any foreign debris from within the service access ar...

Page 25: ...the other end of the hose point the pre filter into a suitable drain turn on the water and allow any sediment to be flushed down the drain Once the water stream runs clear turn off the hose 4 Put the...

Page 26: ...tomatically trip the hot tub s circuit breaker DANGER If this breaker does not trip immediately call your electrician Do not use your hot tub Only if pushing this button successfully trips this circui...

Page 27: ...t the light is on 8 Press the Light button a second time to turn off the light 9 If equipped press the Jets 2 button You should hear the pump turn on see water circulating and see the Jets2 light illu...

Page 28: ...power off After the five minute priming the filtration cycle starts 12 hours later You can also skip the priming period by pressing Warm Cool or Temp for the 4 button panel Filter duration is program...

Page 29: ...EXPORT ONLY VL600S Figure 21 Topside Callouts for VL600S Controls Initial Start Up When your hot tub is first actuated it will go into Priming mode indicated by Pr The priming mode will last for less...

Page 30: ...temperature and again to make the temperature change in the desired direction Jets 1 and Jets 2 Buttons Press the JETS 1 button once to activate the low speed of Pump 1 Press it a second time to acti...

Page 31: ...ring filter cycles SLP or SL will display solid when temperature is not current and will alternate with temperature when temperature is current Preset Filter Cycles The first filter cycle begins six m...

Page 32: ...ed the air from the system see page 43 Turn the power on again Sometimes momentarily turning the pump off on will help prime the pump Do this no more than three times 3 If the water is running smoothl...

Page 33: ...Your Pinnacle Plus PN model hot tub comes with a built in SPA FROG sanitizing system Depending on the area you live in and the local regulatory rules your SPA FROG consists of some combination of a mi...

Page 34: ...p Shock hot tub to establish a 1 0 2 0 ppm bromine or chlorine residual Add directly to hot tub water Do NOT add through the SPA FROG In Line System When spa reaches 95 degrees set the mineral and bro...

Page 35: ...Set SPA FROG Mineral Cartridge wide open on 6 by holding the bottom and turning the top until the number 6 appears in the setting window The SPA FROG Mineral Cartridge must be replaced every 4 months...

Page 36: ...Page 34 For HELP call 800 304 9684...

Page 37: ...age 35 For HELP call 800 304 9684 Electronic Controls for PN Models Your spa is equipped with a full function in K450 keypad Basic operation of this control is provided next Spa Functions for PN Model...

Page 38: ...Page 36 For HELP call 800 304 9684 Programming Steps for PN Models...

Page 39: ...key to confirm new setting If the Light key is not pressed the 25 second automatic timeout will exit Low level configuration mode without changing any setting See below reference table between spa mod...

Page 40: ...water and run with P1 low in Filter cycle only Ozone generator will turn off if there is any user demand for pumps blower or light and remains off 40 minutes after last user demand Filtration Sanitat...

Page 41: ...n your hot tub Keeping the cover in place anytime the hot tub is not in use reduces the heating time and minimizes operating costs The time required for initial heat up varies depending on the startin...

Page 42: ...r lift device W a t e r M a n a g e m e n t Our chemical water purification system is a perfect match for your hot tub If your water quality seems improper increasing the time your hot tub filters the...

Page 43: ...e your hot tub filters per day by turning your filtration cycle time or duration up Heavy Use After a period of heavy use your hot tub may cloud Shock your hot tub with 2 ounces of non chlorine shock...

Page 44: ...not turn off too many jets at the same time This will create backflow and possible damage to your hot tub How do I bleed air from my system When draining and refilling your hot tub the pump may becom...

Page 45: ...artridge into the injector Replace cap and tighten Turning on the pump activates the aromatherapy via the jets What is the insulation made of We use a Thermazone process to fully insulate all of our h...

Page 46: ...our problem please call our customer care center at 800 304 9684 Additional information is also available at www PinnacleSpas com You will need your serial number to access this site Important Most pr...

Page 47: ...f problem persists check for loose electrical connections Check for Neutral wiring error at GFCI Fuse blown Check for blown Fuse 4 F4 inside of spa pack Pump not running No power to hot tub Reset circ...

Page 48: ...s automatically If the hot tub does not reset turn off the GFCI and call service ICE IC Potential freeze condition detected Ice No action required The pump will automatically operate regardless of the...

Page 49: ...dd water if necessary Be sure that slide valves are open Make sure the pump is primed and has power Press any button to reset automatically reset within 15 minutes If the problem persists contact serv...

Page 50: ...cover on the ground wearing of the vinyl could easily develop into a tear 2 The insulating foam in your cover is not designed to hold the weight of a person or an animal Important Cracked foam in the...

Page 51: ...e the front cap 5 Attach a garden hose to the exposed threads and route the hose downhill to your drainage area 6 Twist the drain fitting 1 3 turn counterclockwise to unlock the drain valve and pull i...

Page 52: ...ll our order line at 800 304 9684 to order replacement filters and our special Filter Cleanser Jets Remove and clean the jets as needed using our special Plumbing Cleanser water and a cloth or soft br...

Page 53: ...nitizer a little at a time and testing the water again after two days Surface The acrylic surface of your hot tub should be cleaned with recommended cleaners and thoroughly rinsed with warm not cold w...

Page 54: ...d winterize your hot tub to avoid accidental freezing due to a power or equipment failure We highly recommend that you have a hot tub professional winterize and restart your hot tub WARNING Damage fro...

Page 55: ...olonging equipment life Ozone O3 Produced by an Ozonator Ozone is a form of oxygen O2 and is a powerful oxidizing agent used to destroy organic waste and byproducts and help in the control of algae an...

Page 56: ...11000 Model 1002 Specifications Dimensions 96 L x 96 W x 34 D Seats 6 Water Jets 53 Air Jets 14 Capacity 450 USG 1703 L Dry Weight 900 Lbs 408 Kg Filled Weight 4647 Lbs 2108 Kg Electrical 240VAC 48A...

Page 57: ...03 Specifications Dimensions 84 L x 84 W x 34 D Seats 7 Water Jets 50 Air Jets 14 Capacity 350 USG 1325 L Dry Weight 745 Lbs 338 Kg Filled Weight 3666 Lbs 1663 Kg Electrical 240VAC 48A 60Hz GFCI 60A S...

Page 58: ...01 Specifications Dimensions 84 L x 84 W x 34 D Seats 6 Water Jets 39 Air Jets 14 Capacity 350 USG 1325 L Dry Weight 680 Lbs 308 Kg Filled Weight 3595 Lbs 1630 Kg Electrical 240VAC 48A 60Hz GFCI 60A S...

Page 59: ...4 D Seats 6 Water Jets 32 Air Jets 14 optional Capacity 255 USG 965 L Dry Weight 555 Lbs 252 Kg Filled Weight 2682 Lbs 1216 Kg Electrical 240VAC 40A 60Hz GFCI 50A LX 5000 includes the 14 optional air...

Page 60: ...006 Specifications Dimensions 86 L x 58 W x 30 D Seats 3 Water Jets 19 Air Jets 10 Capacity 175 USG 662 L Dry Weight 480 Lbs 218 Kg Filled Weight 1940 Lbs 880 Kg Electrical 240VAC 40A 60Hz GFCI 50A Sp...

Page 61: ...07 Specifications Dimensions 84 L x 84 W x 36 D Seats 5 Water Jets 41 Air Jets 0 Capacity 310 USG 1173 L Dry Weight 840 Lbs 380 Kg Filled Weight 3427 Lbs 1554 Kg Electrical 240VAC 48A 60Hz GFCI 60A Sp...

Page 62: ...09 Specifications Dimensions 84 L x 84 W x 36 D Seats 6 Water Jets 43 Air Jets 0 Capacity 305 USG 1 155 L Dry Weight 845 Lbs 383 Kg Filled Weight 3390 Lbs 1538 Kg Electrical 240VAC 48A 60Hz GFCI 60A S...

Page 63: ...08 Specifications Dimensions 91 L x 91 W x 36 D Seats 5 Water Jets 50 Air Jets 0 Capacity 375 USG 1 420 L Dry Weight 900 Lbs 408 Kg Filled Weight 4030 Lbs 1828 Kg Electrical 240VAC 48A 60Hz GFCI 60A S...

Page 64: ...0 Specifications Dimensions 91 L x 91 W x 36 D Seats 6 Water Jets 55 Air Jets 0 Capacity 400 USG 1 514 L Dry Weight 906 Lbs 411 Kg Filled Weight 4 244 Lbs 1 925 Kg Electrical 240VAC 48A 60Hz GFCI 60A...

Page 65: ...1 Specifications Dimensions 84 L x 78 W x 34 D Seats 5 Water Jets 31 Air Jets 0 Capacity 285 USG 1 080 L Dry Weight 710 Lbs 322 Kg Filled Weight 3 091 Lbs 1 402 Kg Electrical 240VAC 40A 60Hz GFCI 50A...

Page 66: ...on levels Damage due to shorted heater elements Corrosion at jets Deterioration of pillows filter lid filters any seals and gaskets Note Pinnacle Spas must receive written notification within 10 days...

Page 67: ...ts reliability and your long term satisfaction in mind Your new hot tub is constructed to our strictest quality standards A certificate similar to the one pictured here is created for every hot tub we...

Page 68: ...Page 66 For HELP call 800 304 9684 PN 855 PN 850 PN 743 PN741 PN 631 Exploded View of PN Filter and Spa Frog System...

Page 69: ...qual to the original purchase In such event owner is responsible for expenses including removal shipping and re installation of the existing or replacement hot tub The replacement spa or part will car...

Page 70: ...6101 45th St N St Petersburg FL 33714 800 304 9684 www PinnacleSpas com...

Reviews: