background image

6-5/8"

8

7

6

8"

4"

1

2

5

3

PLACID

CONSTANT CURRENT

POWER SUPPLY

4

The power supply is suitable for Placid Industries brakes up to 220 lb.-in. & clutches up to 130 lb.-in. torque. The power supply is a 

constant current type, with a 3/4 turn potentiometer for setting output current from 0% to 100%.  The cutput current can also be 

controlled with a 0-10 Volt Input Signal or Follower Arm Potentiometer.   The SPAN adjustments set maximum and minimum current 

levels.

Input :    120 Volts A.C.  50 / 60 Hz.,  fused at 1 ampere

Output:  PS-12-MC,   0-12 volts D.C.,   1.25 amps,  15 watts

              PS-24-MC,   0-24 volts D.C.,   0.75 amps,  22 watts

              Fused at 2 amperes (internal)

0-10 Volt Input Resistance: 2000 ohms

1.  % RATED CURRENT potentiometer

2.  Current SPAN MAX. potentiometer

3.  Current SPAN MIN. potentiometer

4.  LED 'Power On' light

5.  L.C.D. digital ammeter

6.  On underside of case: SWITCH for

           Manual (Potentiometer) or

 

 0-10 volt control & Follower control.

7.  Terminal Strip for :

        1) D.C. Output for brake or clutch coil  ( + ,  - )

        2) Ground   (      )

        3) 0-10 Volt Input Signal  ( 0-10v,  COM. )

        4) Follower Arm Potentiometer

8.  A.C. input,   A.C. power On/Off switch,   input fuse

POWER SUPPLY

Specify 12  or 24 Volts D.C.

MODEL:  PS - ( voltage ) - MC

SPECIFICATIONS

07-xxx    1/07

Placid Industries

Lake Placid, NY

+

+

COIL  OUTPUT (dc)            

GREEN

CONTROL

INPUT

FOLLOWER POT

0-10v  COM

PLACID

INDUSTRIES

Phone 518 523-2422
www placidindustries.com

P1/4

Summary of Contents for PS-12-MC

Page 1: ... 24 volts D C 0 75 amps 22 watts Fused at 2 amperes internal 0 10 Volt Input Resistance 2000 ohms 1 RATED CURRENT potentiometer 2 Current SPAN MAX potentiometer 3 Current SPAN MIN potentiometer 4 LED Power On light 5 L C D digital ammeter 6 On underside of case SWITCH for Manual Potentiometer or 0 10 volt control Follower control 7 Terminal Strip for 1 D C Output for brake or clutch coil 2 Ground ...

Page 2: ...ed current of the brake or clutch 8 SPAN MIN Set the RATED CURRENT potentiometer to 10 Adjust the SPAN MIN potentiometer until the output current is 10 of rated current 9 Recheck Steps 6 8 ADJUSTMENTS When Using Manual Potentiometer Control RATED CURRENT POTENTIOMETER To control output current from 0 to 100 SPAN MAX Sets the maximum output current Is a 15 turn potentiometer Use the miniature plast...

Page 3: ...J Using the miniature plastic screwdriver turn the SPAN MAX potentiometer clockwise until the output current equals the 100 rated current of the brake or clutch 8 SPAN MIN Set your 0 10 volt signal to 1 volt Adjust the SPAN MIN potentiometer until output current is 10 of rated current 9 Recheck Steps 6 8 ADJUSTMENTS When Using 0 10 Volt Control 0 10 VOLT INPUT SIGNAL Output current is proportional...

Page 4: ...en the wire is connected output current is controlled by the 0 10v signal With the wire disconnected power supply output current is zero COIL OUTPUT dc INPUT GREEN CONTROL FOLLOWER POT 0 10v COM Computer or PLC BRAKE OR CLUTCH DO NOT power up power down the AC input DO NOT interrupt the DC output wires POWER SUPPLY PS MC Switch or Relay Contacts D C OUT Output Connector On Circuit Board Rated Curr...