Summary of Contents for WMC-1600R

Page 1: ......

Page 2: ...quipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmf...

Page 3: ...packing 3 2 2 Installation 3 2 3 Deciding How to Install the System 3 Chapter 3 IDENTIFYING FRONT PANEL 7 3 1 Front Panel 7 3 2 LED Indicators 7 Chapter 4 CONFIGURING THE SYSTEM 9 4 1 Configure Throug...

Page 4: ...chassis can be deployed with PLANET s smart media converter family Redundant power supply is also provided to enhance the reliability with option of either 100 240V AC power or 48V DC power 1 2 Featur...

Page 5: ...2...

Page 6: ...or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 32 and 104 degrees Fahrenheit 0 to 40 degrees Celsius...

Page 7: ...the rack Step 3 Proceed to the Connecting to Power section 2 3 2 Installing Media Converter The chassis is equipped with sixteen media converter carriers each of which is fitted into bays of the chas...

Page 8: ...the load without any loss Similarly if one power supply is removed from servicing it can be switched off and removed while the chassis continues functioning Protection System The power of each conver...

Page 9: ...clockwise or counter clockwise by using hand or screwdriver Note If the Chassis System needs to work alone you can stick up four Rub ber foot below the chassis 2 3 5 Power Notice 1 The device is a pow...

Page 10: ...detailed information Console Port RS 232 To configure the device through Terminal Emulation Program via RS 232 serial port 10 100Base TX Port To configure the device through Web Browser or TELNET prog...

Page 11: ...8...

Page 12: ...DB9 connector 2 Attach the DB9 serial port female cable connector to the male DB9 serial port connector on the chassis system 3 Attach the other end of the DB9 serial port cable to a remote the workst...

Page 13: ...un the device properly 4 1 3 1 2 Factory Reset This function is to set the device back to the default setting in case of the messy setting 4 1 3 1 3 Image Update The section is to set the TFTP Server...

Page 14: ...rm the setting of admit password System Name to authorize the device system name Location to show the device where it is located Refresh time to set the refreshing time of the device through the web 4...

Page 15: ...il status of each media converter 4 1 3 2 5 Media Converters Setting This screen is to set the Device function of LLCF and Link Enable the Media 1 LLR function Auto Negotiation Speed Duplex Mode Flow...

Page 16: ...ced Mode Dup Duplex mode F for Full Duplex or H for Half Duplex Enable to enable the link of the Media 1 on or off Note Some of the function can be control only depends on the Smart Media Converter 4...

Page 17: ...tation are different default enable Power Fail Trap to set the Power Fail Trap default enable Fan Fail Trap to set the fan fail trap default enable MC Plug in Trap to set the trap when a Media Convert...

Page 18: ...nd password is both root After enter its web interface the Home Page will show out the page for general configuration To set the management system click on the left side menu System Function and Confi...

Page 19: ...nt interface please be sure that the image file is correct 4 2 1 4 Configuration Update The section is explaining how to upload and download the configure setting of the management interface The Confi...

Page 20: ...s 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default Gateway to set the gateway address the default is 192 168 1 254 NOTE After configuring the system device need to p...

Page 21: ...p to set the trap when the Media Converter Module has been pulled out default enable MC Broken trap to set the trap when the Media Converter Module was broken default enable MC Link up trap to set the...

Page 22: ...appen The Redundant functions were set fixed the master slot is slot 1 odd number slot and the slave slot is slot 2 even number slot and there are eight redundant groups in all The Act will indicate w...

Page 23: ...20...

Page 24: ...andard 19 size 2 U Net Weight 7 2kg approx Only one power supply included Fan Rated Voltage 12V DC Speed 3200 RPM 250 RPM Air Delivery 42 5 CFM per min Noise Level 36 5dB A Bearing System Precise ball...

Page 25: ...duplex 200Mbps full duplex LED Indicators Power On Power Fail Fan Fail MGM Console LNK ACT Cable 10BaseT 2 pair UTP Cat 3 4 5 EIA TIA 568 100 ohm STP 100Base TX 2 pair UTP Cat 5 EIA TIA 568 100 ohm ST...

Page 26: ...Part No EM WMCv1...