background image

HD38

6 steps ventithermoregulation

Handbook

SL 6.0

How to connect the sensors
Connect the sensor provided as shown  in  the  diagram.  For  remote  connections  use  a standard
0.5-square millimeter two-pole wire , taking great care   over  the  connections,  by insulating and sealing
the joins carefully.

 -O.C.-

  is displayed when the temperature sensor wiring is open, 

 -S.C.-

  is displayed

when the temperature sensor wiring is short circuit.

How to connect the line
Connect line on terminals L-N.

How to connect the contacts
Output  3-4......13-14  contacts are N.O. (Normally Opened free of voltage) on wich is apliable a 4AMP
AC1 maximum load.

INSTALLATION

HD38

230V  LINE

Common

Ventilation  1

Ventilation 2

Ventilation 3 Ventilation 4 Ventilation 5

Ventilation 6

SX temperat. probe

N.O contacts (normally

opened free to voltage)

max 4AMP AC1.

For HD38/HDY6 connections
use  a standard 0.5-square
millimeter two-pole.

230V LINE

HEAT

ALARM

TEMP

Warning: bridging
here (41-42) outputs
ventilation are
progressive (On-Off
regulation type).

HPAL DOTATION CABLE

N.O contacts (normally
opened free to voltage)
max 4AMP AC1.

230V LINE

Heat

Cool

Temp.alarm

981013

As it is company policy to continually improve the products the

Manufactures reserve the right to make any modifications thereto without
prior notice. They cannot be held for any damage due to malfunction.

Reviews: