The Polaris booster pump supplies high pressure
water to the Polaris pool cleaner to optimize
cleaner efficiency. The pump is not self-priming
and should only be used when the pool filtration
pump is on.

Running it without the filtration

pump will damage the booster pump.

Improper

operation of the booster pump will void 
the warranty.

Important Information

To reduce risk of electrical shock:

Read and follow all instructions.

The electrical hook-up of the pump should be
performed by a licensed electrician and
conform to all national, state and local codes.

Use solid copper bonding conductor, no
smaller than No. 8 AWG (8.4 mm

2

), 6 AWG

(13.3 mm

) in Canada, to connect the motor

to all metal parts of the pool, spa or hot tub
structure, all electrical equipment, and all
metal conduit and metal piping within 5 ft 
(1.5 m) of the inside walls of the swimming
pool, spa or hot tub.

Do not permit children to handle this product.

Use this pump only with permanently installed
pools, and hot tubs and spas if so marked. A
permanently installed pool is constructed in 
or on the ground or in a building, and cannot be
easily disassembled and reassembled.

Installation

Electrical 

The booster pump motor is factory wired for 240
volts, but can be wired for either 120 or 240 volts.
To rewire, follow the instructions on the name
plate located on the back of the motor or the
sizing plate on the side of the motor.

A separate time clock (in addition to the filtration
system time clock) is recommended to control the
On/Off functions of the booster pump. A manual
switch can also be used.

If a time clock is used, set it to turn the pump on
half an hour after the pool filtration pump is
turned on, and turn the pump off at least half an
hour before the filtration pump shuts off.
Periodically check the time clock settings to make
sure they are properly synchronized.

Plumbing

The Polaris Booster Pump requires a dedicated
return line. Plumb the booster pump into the
system so that it always receives flow from the
filtration pump.

To ensure proper function of the pump and the
cleaner, refer to the 

Typical Installation

diagram

and adhere to the following guidelines for 
specific equipment.

Plumb the dedicated line upstream of all air
inducing equipment.

If a heater is installed on the system, tap the 
inlet for the booster pump into the return line
downstream and at least three feet from the
heater discharge.

Do not tap the booster

pump inlet into the three-foot section of
heat sink pipe that comes directly out of
the heater.

Some solar heating systems utilize the entire
water flow when the panels are being purged
of air.

If the pump is installed in a non-flow

pipe during solar panel purges, install an
automatic override to shut off the pump.

Plumb the booster pump inlet higher,
upstream and as far away as possible from
the chlorinator.

Polaris Booster Pump 

Installation Instructions

Minimum
of 3 feet

From
Pool

Filtration Pump

Pool Filter

Heater

Polaris

Booster
Pump

Note: 

Plumb the booster pump up-

stream of all air inducing equipment.

To
Pool

Chlorinator

Solar

System

Plumbing

Options

1, 2 or 3

To

Spa

Typical Installation

Summary of Contents for PB4-60Q

Page 1: ...me clock is recommended to control the On Off functions of the booster pump A manual switch can also be used If a time clock is used set it to turn the pump on half an hour after the pool filtration pump is turned on and turn the pump off at least half an hour before the filtration pump shuts off Periodically check the time clock settings to make sure they are properly synchronized Plumbing The Po...

Page 2: ...hread sealant 3 Measure and cut reinforced hose ensuring cut is clean with no more than a 30º off straight edge Avoid unnecessary loops or bends in the hose 4 Push the hose onto the quick connect until it is flush against the hose barb base 5 Holding the hose in place pull and twist the sleeve on the quick connect over the hose as far as possible Snap the clip into place Checking Water Flow After ...

Page 3: ...the consumer must deliver or ship the unit or the warranty parts freight prepaid to the nearest Polaris Authorized Service Center or return it freight prepaid after proper authorization to the plant of manufacture Authorization to return a unit to the plant of manufacture must be obtained from the Polaris Customer Service Department For your convenience please check with your dealer for the local ...

Page 4: ...Quick Connect Retainer 4 R OTAT I O N Inlet 13 1 3 6 2 8 9 10 12 11 9 14 4 7 Outlet 16 17 18 15 No Part Description Qty Polaris Booster Pump Part PB4 60 No Part Description Qty 1 P5 Volute Includes Drain Plug 1 2 P15 Impeller 1 3 P55 Seal Stainless Steel Cup Spring 1 4 P95 O Ring Bracket 1 5 P10 Bracket 1 6 P35 Bolt Stainless Bracket to Motor 2 7 P40 O Ring for Shaft 1 8 P61 Motor 3 4 HP Threaded ...

Reviews: