LIMITED WARRANTY
Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original purchaser only,
the RP type Electric Filter Pump against defects in material and workmanship for 180 days from the date of
purchase. Original Purchaser must retain proof of such purchase in the form of an original store sales receipt and
must produce such upon request by Polygroup or its designated agents. Warranty claims cannot be processed
without a valid proof of purchase.
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or
replacement of the product, to be decided in Polygroup’s sole discretion. Consequential damages, including claims
for loss of water, pool chemicals, damage, or labor are not covered under this Limited Warranty.
This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by
unauthorized persons; use non-Polygroup parts or accessories with the product; use the product in contravention
of the Manufacturers Instructions; use improper voltage; abuse the product in any way; or through accident or
negligence. Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the control of
Polygroup.
IN NO EVENT SHALL POLYGROUP, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE
BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or others
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
Should you encounter a problem with your Polygroup Product, please do not return the product to the place or
purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Customer Service, please
first review the Troubleshooting Guide in the Installation Manual, or review the FAQ at www.polygroup.com . If you
are still unable to correct the problem, please contact Polygroup customer service at (888) 919-0070. Have the
product type and your purchase receipt ready. Our Customer Service Representative will assist you in resolving the
problem. You may be asked to return all or part of the product for inspection and/or repair. Do not return any
product to Polygroup without a Return Authorization number.
2X
4X
F1000C / F1500C / F2000C
F600C / F700C
IMPORTANT SAFETY INSTRUCTIONS
1.
READ AND FOLLOW ALL INSTRUCTIONS
7.
SAVE THESE INSTRUCTIONS.
When installing and using this electrical equipment, basic safety precautions should always be followed, including
the following:
2.
WARNING -
To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times by an adult who is capable of assisting a child in distress.
3.
WARNING -
Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault
circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section 680-31 of the National Electrical
Code. Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI.
4.
WARNING -
To reduce the risk of electrical shock, replace damaged cord (with pump body) immediately.
NEVER bury cord. Locate cord to eliminate abuse or contact from lawn mowers, hedge trimmers, and other
equipment. NEVER use an extension cord to connect unit to electric supply; provide a properly located outlet.
5.
CAUTION -
The power filter is for use with storable pools only. DO NOT use with permanently installed pools.
A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original
integrity. A permanently installed pool is constructed in or on the ground or in a building so that it cannot be
readily disassembled for storage.
6.
CAUTION -
For continued protection against possible electric shock, use only original equipment
manufactured (OEM) parts for your replacement requirements.
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble
your Type RP Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC)
“Swimming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (15) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will hold as
many as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the proper number of
chlorine tablets to add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs.
You must have the type of Filter Cartridge (15) with a central core mesh divider (See page 3) to use the
chlorine dispenser. DO NOT use this to dispense powdered chlorine, shock treatment or any other type of
chemicals as damage to the pump, filter cartridge, and pool will occur.
PRELIMINARY STEPS
POWER FILTER
IMPORTANT NOTES:
2
RP TYPE SWIMMING POOL FILTER SYSTEM
OWNER’S MANUAL FOR ABOVE
GROUND SWIMMING POOLS
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
To order parts, accessories, or answers to frequently asked questions
about your product please visit
WWW.POLYGROUP.COM Customer Service: (888) 919-0070
Avenida Xian Xing Hai, Centro Golden Dragon, 11 Andar M, Macau
IMPORTANT SAFETY INSTRUCTIONS
1. POWER FILTER INSTALLATION
2. DIVERTER FITTING USE
3. PUMP MOTOR PROTECTION
4. PUMP OPERATION
5. FILTER CARTRIDGE CLEANING INSTRUCTIONS
6. POOL MAINTENANCE
7. POOL WATER CARE
8. TROUBLE SHOOTING GUIDE
9. POWER FILTER DISASSEMBLY AND STORAGE
ASME COMPLIANT SUCTION FITTING INFO
2
4
5
5
5
6
6
7
8
8
9