SFS TYPE SWIMMING POOL FILTER SYSTEM
OWNER’S MANUAL FOR ABOVE GROUND
SWIMMING POOLS
IMPORTANT SAFETY INSTRUCTIONS
1. POWER FILTER INSTALLATION
2. PUMP OPERATION
3. PUMP MOTOR PROTECTION
4. FILTER CARTRIDGE CLEANING INSTRUCTIONS
5. POOL MAINTENANCE
6. POOL WATER CARE
7. TROUBLE SHOOTING GUIDE
8. POWER FILTER DISASSEMBLY AND STORAGE
PART LIST
2
3
4
4
5
5
5
6
7
8
084-120839 with GFCI - 2014
2
1
PRELIMINARY STEPS
POWER FILTER IMPORTANT NOTES:
1.
READ ALL INSTRUCTIONS CAREFULLY
and get a thorough understanding of what is required to
assemble your Type SFS Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC)
“Swimming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (9) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will hold as
many as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the proper number of
chlorine tablets to add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs.
You must have the type of Filter Cartridge (9) with a central core mesh divider (See page 3) to use the
chlorine dispenser. DO NOT use this to dispense powdered chlorine, shock treatment or any other type of
chemicals as damage to the pump, filter cartridge, and pool will occur.
4. These Skimmer Filter Systems are manufactured by Polygroup and ETL control number 4000608 - double
insulated and grounded - 115 V.A.C. - 60 Hz. (Unit must have a minimum of 105 V.A.C. to start and run properly.)
The units’ wattage and capacity is as follows:
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
Avenida Xian Xing Hai, Centro Golden Dragon, 11 Andar M, Macau
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner,
the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground
current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and
have the problem corrected by a qualified service representative before using.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
Press
"RESET"
Button
To Start
Pump
Operation
How to use the GFCI plug:
*Do not connect
to a timer device
To order parts, accessories, or answers to frequently asked questions
about your product please visit WWW.POLYGROUPSTORE.COM
Customer Service: (888) 919-0070
To watch how to setup your product please visit:
WWW.POLYGROUP.COM/VIDEO
DO NOT RETURN PRODUCT TO STORE
12X
2X (One Spare)
2X
F1000C / F1500C / F2000C
F600C & F700C
PATENT
PENDING
FILTER
SYSTEM
2X
Should you encounter a problem with your Polygroup Product, please do not return the prod-
uct to the place or purchase. All Warranty claims must be made directly to Polygroup. Prior to
contacting Customer Service, please first review the Troubleshooting Guide in the Installation
Manual, or review the FAQ at www.polygroup.com.
Please review setup instruction videos on
www.polygroup.com/video.
If you are still unable to correct the problem, please contact Poly-
group customer service at (888) 919-0070. Have the product type and your purchase receipt
ready. Our Customer Service Representative will assist you in resolving the problem. You may
be asked to return all or part of the product for inspection and/or repair. Do not return any
product to Polygroup without a Return Authorization number.
WARNING -
To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
WARNING -
Risk of Electric Shock. Connect only to a grounding type receptacle.
This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug or cord is needed, use only identical replacement parts.
WARNING -
To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING -
To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION -
To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appli-
ances closer than 5 feet (1.5 m) from the pool.
CAUTION -
This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of
being readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such
that it cannot be readily disassembled for storage.