background image

Pancake Compressor

Instruction

manual

The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.

Model No. ______________________________________

Type ___________________________________________

Serial No. _______________________________________

IMPORTANT

Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.

Part No. D26130-041-1

ESPAÑOL: PÁGINA 19

FRANÇAISE : PAGE 37

To learn more about Porter-Cable 

visit our website at: 

http://www.porter-cable.com

MODEL 

CPFAC2040P

Copyright © 2004 Porter-Cable Corporation

PROFESSIONAL POWER TOOLS

Summary of Contents for C2000

Page 1: ...______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations Part No D26130 041 1 ESPAÑOL PÁGINA 19 FRANÇAISE PAGE 37 To learn more about Porter Cable visit our website at http www porter cable com MODEL CPFAC2040P Copyright 20...

Page 2: ... the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from br...

Page 3: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Page 4: ...ondensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments Excessive vibration can weaken the air tank and cause rupture or explosion The tank is desi...

Page 5: ...rect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Air o...

Page 6: ...othing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD ...

Page 7: ... parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Transporting Compressor Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oil leaks will damage carpet paint or other surfaces in vehicles or trailers ...

Page 8: ... restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying ...

Page 9: ...rounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The out...

Page 10: ... NOT USE 16 OR 18 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with...

Page 11: ...Safety Valve Pressure Switch Tank Pressure Gauge Outlet Pressure Gauge Regulator Quick Connect Description of Operation Become familiar with these controls before operating the unit On Auto Off Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air ta...

Page 12: ...he compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Air Compressor Pump not shown Compresses air into the air tank Working air is not available until the comp...

Page 13: ... tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety Valve Drain Tank NOTE See Operation section for the location of controls Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources compressed air or moving par...

Page 14: ...d the reinstalled Open Drain Valve Closed Drain Valve To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual or purchase a standard hose clamp at a local hardware store SERVICE AND ...

Page 15: ...Apply pipe sealant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 Reapply pipe sealant to outlet pressure gauge and quick connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulato...

Page 16: ... is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve ca...

Page 17: ...17 ENG D26130 NOTES ...

Page 18: ...aser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRANTY DOE...