Solid Fuel Stoves Manual v4. Issued - 11/03/2014 (382)
SOLID FUEL
HEATING STOVES
MULTI-FUEL MODELS
INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
All Portway Stoves exceed the safety and performance requirements of European Standards
Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.
Independently tested by SGS Environmental Laboratory BV, Arnhem
Portway No1
Portway No2
Portway No3
Portway Inset
Fuel
Wood (Beech)
Mineral Fuel
(Anthracite)
Wood
(Beech)
Mineral Fuel
(Anthracite)
Wood
(Beech)
Mineral Fuel
(Anthracite)
Wood (Beech)
Mineral Fuel
(Anthracite)
Test Standard
EN 13240:2001+A2 2004
EN13229: 2001
Test Cycle
1.15kg over
0.75hrs
0.76kg over
1.1hrs
1.51kg over
0.72hrs
1.05kg over
1.0hrs
2.15kg over
0.73hrs
1.65kg over
1.01 hrs
1.06kg over
0.82hrs
0.74kg over
1.01 hrs
Settings
Primary 0,
2nd 25mm
Primary 30,
2nd 25mm
Primary 0,
2nd 25mm
Primary 35,
2nd 20mm
Primary 0,
2nd 25mm
Primary 45,
2nd 25mm
Primary 5,
2nd 30mm
Primary 32,
2nd 20mm
Flue Draught Pa (ins WG)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
Efficiency %
78.8
78.2
78.2
77.3
76.3
70.0
76.5
75.5
Recommended Output Rating kW
4.9
4.9
6.9
6.9
9
9
4.7
4.7
Output when fitted with reducer
brick pair, kW
3.0
3.0
5.0
5.0
7.1
7.1
2.9
2.9
Mean Flue Gas Temp Rise ºC
226
216
280
292
297
358
237
273
Minimum air entry requirement
2700 mm ²
3800 mm ²
4900 mm ²
2700 mm ²
Minimum Clearance to
combustibles (allow min 50mm
clearance to non-combustibles)
350mm
300mm
300mm
With 150mm or longer legs or base fitted, hearth temperature is <100°C – A light duty hearth
may be used.
In masonry fireplace, 150mm
at sides
350mm above
E
m
is
si
o
n
s
a
s
if
02
=
1
3
%
NOx mg/m³
44
-
77
-
55
-
66
-
CO %
0.19
0.10
0.14
0.08
0.19
0.08
0.35
0.08
CxHy mg/m³
169
-
94
-
205
-
761
-
Gas flow g/sec
4.6
5.4
5.4
6.1
7.3
10.0
4.6
5.0
Smoke Emission mg/m³
38
21
74
36
135
21
78
14
Read these instructions! Use only recommended fuels!
This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of Building
Law. It must be left with the householder and placed where it can easily be found.
INSTALLED AT LOCATION:
BY:
EMERGENCY CONTACT:
Flue Draught measured
on commissioning:
Fuel used on
commissioning
I definitively assert that this installation is safe, has been lit and demonstrated to the householder,
conforms with current building regulations and with these instructions
SIGNED: DATE:
TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY
SWEEP, CONTACT:
UK:
The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55
7AS Tel:0845-601-4406 www.solidfuel.co.uk
RoI:
Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1
Tel:01-801-5959 www.fireplace.ie
Portway 1, 2, 3 and Inset stoves may be used in smoke control areas
when operated strictly in accordance with these instructions and with
Soliftec Smoke Advice Sheet No1
(
www.soliftec.com/smokeadvice.htm
), when burning:
UK:
Untreated wood logs or authorised smokeless fuels (
Exempted from s20
of the Clean Air Act 1993
)
RoI:
Wood logs, smokeless fuels or peat briquettes, but not petroleum coke
(Control of Atmospheric Pollution Regulations, 1970)
1
Pa
WG
PRODUCTION NUMBER