Page 1 of 3
Posh Domaine Brass Rail Shower 3 Functions Chrome (4*)
Plumbers, please ensure a copy of the Installation
Instructions are left with the end user for future reference
Installation Instructions
Step 2
Match the mounting brackets to wall bosses and push
into place.
Slide the rail up or down to centralise the brackets.
Remove the rail and tighten the tensioning screws firmly.
Relocate the rail onto wall bosses and tighten grub
screws top and bottom.
•
•
•
•
Step 3
To adjust slider position, rotate the slider
handle to unlock and lock the slider as shown.
•
Unlock
Lock
1850mm (Recommended)
655mm Rail
555mm
Grub Screw
Underside
Grub Screw
Topside
FLOOR
Step 1
Mount the wall boss housings in
desired position with the screws. Check
the mounts are vertically aligned.
Ensure the grub screws are located on
the correct sides as shown.
•
Rail
Slider
Grub Screw
Internal
Mounting
Bracket
Elbow
(if supplied)
Self Tapping Screw
*This product must be installed in
compliance with all relevant regional
regulations.
It is the responsibility of the installer to
ensure a waterproof seal is achieved
between the product and mounting
surface. If in doubt about the quality of
the seal, remove the product and
reinstall using silicone to ensure a seal is
achieved.
All pipe work must be thoroughly flushed
prior to the installation of the hose.
After installation all connections must be
checked for leaks.
All outlets used primarily for personal
hygiene shall deliver water at a safe
temperature as per regional regulations.
•
•
•
•
IMPORTANT:
Please read all of the
instructions before installation.
General:
•
Wall Plug
(Recommended)
Important Installation Considerations
1. NOTE: Some showers may not provide an effective shower when used
with gravity fed heated water systems or where pressures are less
than 150kPa at the outlet. Additionally showers with flow rates of less
than 9L/min may not allow the following to function correctly:
_ some instantaneous water heaters
_ some tempering valves
_ some thermostatic mixing valves
2. Some shower heads only operate correctly when hot and cold water
supplies are both mains pressure and may not be suitable for some
instantaneous hot water services.
3. When water pressure is in excess of 500kPa a pressure limiting device
is required in accordance with AS/NZS 3500 1.12 recommendation
www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to
customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0284
ISSUE A
DECEMBER 2015
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at
www.methven.com
TWIN SHOWER SYSTEM
Installation Guide
Recommended installation of pressure limiting
valve if supply exceeds 500kPa
NOTE:
- After installation all connections must be
checked for leaks
- All installations must be carried out in
compliance with relevant water regulations*.
Important Installation Considerations
1. NOTE: Some showers may not provide an effective shower when used
with gravity fed heated water systems or where pressures are less
than 150kPa at the outlet. Additionally showers with flow rates of less
than 9L/min may not allow the following to function correctly:
_ some instantaneous water heaters
_ some tempering valves
_ some thermostatic mixing valves
2. Some shower heads only operate correctly when hot and cold water
supplies are both mains pressure and may not be suitable for some
instantaneous hot water services.
3. When water pressure is in excess of 500kPa a pressure limiting device
is required in accordance with AS/NZS 3500 1.12 recommendation
www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to
customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0284
ISSUE A
DECEMBER 2015
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at
www.methven.com
TWIN SHOWER SYSTEM
Installation Guide
Recommended installation of pressure limiting
valve if supply exceeds 500kPa
NOTE:
- After installation all connections must be
checked for leaks
- All installations must be carried out in
compliance with relevant water regulations*.