Part 1 

 
 
 
 

FCC Notes: 

This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions manual, may cause interference 
to radio communications. It has been tested and found to comply with limits for a Class 
A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to 
provide reasonable protection against interference when operated in a commercial 
environment. Operation of this equipment in a residential area is likely to cause 
interference in which case the user at his own expense will be required to take whatever 
measures to correct the interference. 

Warranty Limits: 

Warranty terminates automatically when  any person other than the authorized 
technicians opens the machine. The user should consult his/her dealer for the problem 
happened. Warranty voids if the user does not follow the instructions in application of 
this merchandise. The manufacturer is by no means responsible for any damage or 
hazard caused by improper application. 

About This Manual: 

Posiflex has made every effort for the accuracy of the content in this manual. However, 
Posiflex will assume no liability for any

 

technical inaccuracies or editorial or other 

errors or omissions contained herein, nor for direct, indirect, incidental, consequential 
or otherwise damages, including without limitation loss of data or profits, resulting 
from the furnishing, performance, or use of this material.

 

This information is provided  “as is” and Posiflex Technologies, Inc. expressly 
disclaims any warranties, expressed, implied or statutory, including without limitation 
implied warranties of merchantability or fitness for particular purpose, good title and 
against infringement. 
The information in this manual contains only essential hardware concerns for general 
user and is subject to change without notice. Posiflex reserves the right to alter product 
designs, layouts or drivers without notification. The system integrator shall provide 
applicative notices and arrangement for special options utilizing this product. The user 
may find the most up to date information of the hardware from web sites: 
http://www.posiflex.com or http://www.posiflex.com.tw 
All data should be backed-up prior to the installation of any drive unit or storage 
peripheral. Posiflex will not be responsible for any loss of data resulting from the use, 
disuse or misuse of this or any other Posiflex product. 
All rights are strictly  reserved. No part of this documentation may be reproduced, 
stored in a retrieval system, or transmitted in any form or by any means, electronic, 
mechanical, photocopying, or otherwise, without prior express written consent  from 
Posiflex Technologies, Inc. the publisher of this documentation. 

©

 Copyright Posiflex Technologies, Inc. 2009

 

All brand and product names and trademarks are the property of their respective holders. 

P/N:

 

19230900040

 

CR-2200 SERIES 

CASH DRAWER 

USER’S MANUAL 

                                               

Rev. B0

 

Summary of Contents for CR-2200 Series

Page 1: ...loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains on...

Page 2: ...function for maximum cash security l Check slot with check storage underneath cash tray for non cash or large bill transaction without opening drawer l 2 fixed and 4 adjustable total 6 bill compartments l 1 fixed and 7 adjustable total 8 coin compartments Partially adjustable in size and number by use of coin compartment separator l Provided with various interface selection including direct printe...

Page 3: ...terminals all Posiflex POS printers most Epson POS printers most Star POS printers and all other compatibles The user may cut the 6 pin end or order the ready cut cable CCBLA 180A and assemble this free end according to his POS printer specification if the POS printer used applies different connection The cable connection on CCBLA 180A is as below Wire color RJ45 Function Red Pin 1 Drawer open sen...

Page 4: ...lug to CR port of POS system or POS printer as shown below 2 Turn the keylock to standby position CR 2204 1 Connect the 4 pin RJ9 plug of RS232 conversion cable to the RJ9 jack at the rear side of CR 2204 and connect the DB 9 pin connector to RS232 port of host PC or POS system as shown in drawing below 2 Check the specification of power adaptor on its nameplate Insert the Coin Compartment Separat...

Page 5: ...cation of power adaptor on its nameplate Insert the power adaptor into the correct power outlet Insert the output plug to the power jack at rear side of CR 2205 to supply power for drawer kickout 4 Turn the keylock to standby position 5 Install the USB utility driver from Posiflex Product Information CD with Posiflex POS system or visit our web sites http www posiflex com or http www posiflex com ...

Page 6: ... cash drawer as in below table so that this cash drawer is going to respond accordingly in USB communication Please note that within each system there should never be any 2 USB interface cash drawers carrying the same drawer number USB PID JP1 SW 1 2 3 4 5 6 7 0 2 ON ON ON OFF OFF OFF OFF ON 3 ON OFF OFF ON ON OFF OFF ON 4 OFF ON OFF ON OFF ON OFF ON Default setting Drawer 7 SW2 OFF SW3 OFF SW4 OF...

Page 7: ... in Posiflex Product Information CDROM or go to Posiflex web sites http www posiflex com or www posiflex com tw or www posiflexusa com for USB Cash Drawer Test Program If you use the Posiflex Product Information CDROM that comes with any Posiflex POS system please go to folder Drivers CR USB and click SETUP EXE to install the USB Cash Drawer Test Program 2 Start up the test program and click STATU...

Page 8: ...e 10 max Max Current Consumption 0 75A 12 VDC 1A 24 VDC AC Adaptor for CR 2204 2205 Input Voltage 120 VAC 10 240 VAC 10 50 60 Hz Output Voltage 12 VAC at 1 5 A Interface Direct Drive CR 2200 Serial RS232C CR 2204 Baud rate 9600 19200 Parity none Data Bits 8 Stop Bits 1 USB 1 1 CR 2205 Security Code CR 2205 USB PID Drawer Open Sense CR 2200 Drawer open sense circuit shorts when drawer open CR 2204 ...

Page 9: ...nt Adjustable Bill compartment Check Storage Lock Physically lock the drawer Open Open the drawer by the key At this position the key can t be extracted and will be automatically springed away once released Standby Automatically open the drawer by POS printer or POS system or interface signal control Keylock Check Slot ...

Page 10: ...Part 10 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...