background image

FCC Notes: 

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, 

may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to EN55022 and 47 
CFR, Part 2 and subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial 

environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to 
take whatever measures to correct the interference.

For CE-countries:

This scanner is in conformity with CE standards. Please note that an approved, CE-marked power supply unit should be used in order to 

maintain CE conformance.

Laser Safety:

The laser scanner complies with safety standard IEC 60825 –1 for a Class I laser produce. It also complies with CDRH as applicable to a 

Class IIa laser product.  Avoid long term staring into direct laser light.

Radiant Energy: 

The laser scanner uses one low-power visible laser diodes operating at 650nm in an opto-mechanical scanner resulting in less than 3.9

μ

radiated power as observed through a 7mm aperture and averaged over 10 seconds.
Do not attempt to remove the protective housing of the scanner, as unscanned laser light with a peak output up to 0.8mW would be accessible inside.

Laser Light Viewing:

 The scan window is the only aperture through which laser light may be observed from this product.  A failure of the scanner motor, 

while the laser diode continues to emit a laser beam, may cause emission levels to exceed those for safe operation.  The scanner has safeguards to prevent 
this occurrence.  If, however, a stationary laser beam is emitted, the failing scanner should be disconnected from its power source immediately.

Adjustments:

Do not attempt any adjustments or alteration of this product.  Do not remove the protective housing of the scanner.  There are no user-

serviceable parts inside.

Caution:

 Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

Optical:

The use of optical instruments with this product will increase the eye hazard.  Optical instruments include binoculars, magnifying glasses, and 

microscopes but do not include normal eye glasses worn by the user.

Warranty Limits: 

Warranty terminates automatically when any person other than the authorized technicians opens the machine. The user should consult 

his/her dealer for the problem happened. Warranty voids if the user does not follow the instructions in application of this merchandise. The manufacturer is 

by no means responsible for any damage or hazard caused by improper application.

No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed, or translated into any language or 
computer language in any form or by any means electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without express 
written consent and authorization.
We reserve the right to make changes in product design without reservation and without notification.  The material in this guide is for 
information only and is subject to change without notice.
All trademarks mentioned herein, registered or otherwise, are the properties of their various respective owners.

About This Manual:

Posiflex Technologies, Inc. has made every effort for the accuracy of the content in this manual. However, Posiflex Technologies, Inc. will assume no 

liability for any technical inaccuracies or editorial or other errors or omissions contained herein, nor for direct, indirect, incidental, consequential or
otherwise damages, including without limitation  loss of data or profits, resulting from furnishing, performance, or use of this material.

This information is provided “as is” and Posiflex Technologies, Inc. expressly disclaims any warranties, expressed, implied or statutory, including without 
limitation implied warranties of merchantability or fitness for particular purpose, good title and against infringement.
The information in this manual contains only essential hardware concerns for general user and is subject to change without notice. Posiflex Technologies,

Inc. reserves the right to alter product designs, layouts or drivers without notification. The system integrator shall provide applicative notices and
arrangement for special options utilizing this product. The user may find the most up to date information of the hardware from: http://www.posiflex.com or 

http://www.posiflex.com.tw or http://www.posiflexusa.com
All data should be backed-up prior to the installation of any drive unit or storage peripheral. Posiflex Technologies, Inc. will not be responsible for any loss 

of data resulting from the use, disuse or misuse of this or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, 

electronic, mechanical, photocopying, or otherwise, without prior express written consent from Posiflex Technologies, Inc. the publisher of this
documentation.

©

 Copyright Posiflex Technologies, Inc. 2009

All brand and product names and trademarks are the property of their respective holders.

LS-1000 Series

Laser Barcode Scanner

User’s Manual

Rev. A0

P/N: 18050900030

Page 1

Summary of Contents for LS-1000 Series

Page 1: ... happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application No part of this document may be reproduced transmitted stored in a retrieval system transcribed or translated into any language or computer language in any form or by any means electronic mechani...

Page 2: ...the interface cable to an appropriate USB or RS232 port Fig 4 Connect the power adaptor to the power input connector on interface cable Fig 5 or set the 5V power support in pin 9 of the system COM port for RS232 model Set the COM port protocol to 9600 n 8 1 and no handshaking for RS232 model Peel off the protective film on scanner for ready to use after all the operations done The scanner will alw...

Page 3: ...anning performance you could expect The scanner includes key features as z Button switch in between omni directional and single line scanning capability ideal for increasing your operating efficiency z Powerful 20 line scan pattern yields 9 1400 scans per second for omni directional scanning 9 74 scans per second for single line scanning z Implement with the proprietary real time hardware decoding...

Page 4: ...er onto the bracket of SK 200 kit Interface Cable Connector For USB interface cable connection Operation Status When the scanner powers up the buzzer gives four beeps and the LED indicator in function button glows Present a known good test barcode to the scanner The scanner should issue a short beep and the LED should flash red momentarily Note Refer to LED Indications and Beeper Indications secti...

Page 5: ...eters may be set at any time without affecting the other parameters Scan Test With the scanner running LED blue and the host system on with an active window of a text editor try to scan several known good barcodes Check the results on the system screen If the scanner is reading okay no further setup may be necessary If the POS screen does not show the expected scans go to Set Up below Reset to Def...

Page 6: ...wn good barcodes If results are good you are done setting up Otherwise return to step 1 and try again A demonstrative process flow chart is given below to illustrate the whole setup process Page 6 Read Enter Exit programming mode barcode to start configuration Change scanner setting by scanning required mode barcode Read Enter Exit programming mode barcode to save and exit Display Firmware Version...

Page 7: ...ure the scan line crosses every bar and space of the symbol code as indicated in the right Press the function button to decode and transmit the barcode the good read beeps once For consecutive single line scan present the next barcode and press the function button within 5 seconds When the function button is released it automatically switches back to omni directional scan mode in 5 seconds Press t...

Page 8: ...ow loud beeper cycle every level of setting beeps twice Release the button when you hear the right beeps The scanner beeps accordingly Note The volume setting in this way is not saved in non volatile memory In other words the change will be lost by power off and reset to the configured setting Use the advanced programming guide to set the changes if you wish to keep the changed volume setting LED ...

Page 9: ...ing the scan window The scan window may be cleaned while the scanner is running Replacing Interface Cable The standard interface cable is attached to the scanner with an 10 pin modular connector When the connector is properly seated it is secured in the scanner by a flexible retention tab The cable is designed to be field replaceable Replacement cables can be obtained from your authorized distribu...

Page 10: ...utton to wake up the scanner or present an object close to the scan window The LED remains red and blue purple Possible failure of the scanning safeguard circuit Disconnect the scanner from its power source immediately and contact your dealer There is no proper handshaking with the POS system Check connection and communication settings of the host POS system A stray barcode is sitting somewhere in...

Page 11: ...ed earlier for conceptual understanding Please cover the unwanted codes for scanning the specific code required for the programming to prevent confusion in code scanning Use the download file from our web for advanced programming Display Firmware Version Note The reading of the Display Firmware Version label will read out the firmware version and exit the programming mode Abort Exit programming mo...

Page 12: ...arameters back to default values but leaving the interface mode unchanged It is suggested to scan also the Return to USB default or Return to RS232 default label after this for LS 1000 scanners Return to USB default US Keyboard Return to RS232 default Page 12 ...

Page 13: ...Message Terminator Enter Message Terminator H tab Message terminator None International Keyboard ALT method Page 13 ...

Page 14: ...Return to customer default Note The reading of the label will recover all parameter back to customer default Codabar Enable Save as customer default Codabar Disable Page 14 ...

Page 15: ...Full ASCII CODE 39 Disable Code 39 Enable Code 39 Disable Full ASCII CODE39 Enable Page 15 ...

Page 16: ...UPC EAN JAN Disable UPC EAN JAN Enable ITF 2 OF 5 Disable ITF 2 of 5 Enable Page 16 ...

Page 17: ...UPC EAN ADD ON OFF ADD ON 5 only ADD ON 2 only ADD ON 2 or 5 Page 17 ...

Page 18: ...EAN UPC Add on none mandatory Force UPC A to EAN 13 format enable EAN UPC Add on mandatory Force UPC A to EAN 13 format disable Page 18 ...

Page 19: ...EAN 13 Convert to ISBN ISSN Enable EAN 13 Convert to ISBN ISSN Disable EAN 128 Enable EAN 128 Disable Page 19 ...

Page 20: ...Code 128 Enable Code 128 Disable Code 93 Enable Code 93 Disable Page 20 ...

Page 21: ...Chinese Post Code Enable Chinese Post Code Disable Code 32 Italian Pharmacy Code Enable Code 32 Italian Pharmacy Code Disable Page 21 ...

Page 22: ...MSI enable MSI Disable Enter Exit Programming Mode Page 22 ...