background image

© Baxi Heating UK Ltd 2008

User Guide and
Important Warranty Information

Please keep these instructions in a safe place.

If you move house, please hand them over to 

the next occupier.

Promax Combi

HE Plus LPG

Condensing 

Combination Boiler

You can rely on

Summary of Contents for Boiler

Page 1: ...8 User Guide and Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Promax Combi HE Plus LPG Condensing Combination Boiler You can rely on ...

Page 2: ...1 6BF Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Heating UK Ltd is a BS EN ISO 9001 Accredited Company The code of practice for the installation commissioning servicing of central heating systems Potterton supports 1 0 Quick Reference...

Page 3: ...tor will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade Central Heating Sy...

Page 4: ... on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN section between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES ...

Page 5: ...15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER Tell them the boiler is an LPG Propane model YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of...

Page 6: ...alls below 0 5 this may indicate a leak on the central heating system Fig 2 Error Code E119 will be shown on the display 3 2 To Re Pressurise the System Optional Filling Loop 1 The procedure is for the optional filling loop kit when fitted However even if your boiler has an external loop the principle is similar 2 Look at the boiler from underneath There will be two taps at the end of copper pipes...

Page 7: ...arning labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Fig 34 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in...

Page 8: ...E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your instal...

Page 9: ...nstaller is registered by telephoning 0800 915 0485 or writing to 1 Elmwood Chineham Park Crockford Lane Basingstoke RG24 8WG or check online at www trustcorgi com The boiler meets the requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired...

Page 10: ...7 0 Notes 10 Baxi Heating UK Ltd 2008 ...

Page 11: ... the boiler and can be closed by turning their taps to the right towards the wall Fig 6 4 Call your Installer or Service Engineer as soon as possible IMPORTANT This boiler operates on LPG Propane Familiarise yourself with any control and isolation valves If in doubt consult your installer about the operation of these devices If you smell gas Turn off the gas supply and call your gas supplier immed...

Page 12: ... have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boiler serial number What this warranty covers Free of charge repair or replacement of components found to be faulty from manufacture Free of charge replacement of the complete unit provided always that the f...

Reviews: