background image

Performa 28

Gas Fired Wall Mounted Combination Boiler

User’s Operating
Instructions

Please keep these instructions safe.
Should you move house, please hand
them over to the next occupier.

Summary of Contents for Performa 28

Page 1: ...Performa 28 Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Please keep these instructions safe Should you move house please hand them over to the next occupier ...

Page 2: ...ee operates from the date installation is completed for the customer who is the original user To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which beco...

Page 3: ...o under Gas in the phone directory 1 3 Servicing your Appliance 1 For reasons of safety and economy your appliance should be serviced annually Servicing must be performed by a competent person Your Installer or British Gas Service will be able to advise you 1 4 Electricity Supply 1 THIS APPLIANCE MUST BE EARTHED 2 A standard 230V 50Hz supply is required The appliance must be protected by a 3 amp f...

Page 4: ...r Neons 6 to 11 have a dual function indicating the temperature of the central heating water when constantly illuminated If a fault develops the appropriate neon will begin to flash Refer to Sections 3 3 to 3 7 2 1 0 4 3 bar 30 40 50 60 70 80 Reset Fig 3 30 40 50 60 70 80 1 On Off Reset Selector Switch 2 Central Heating Temperature Control 3 Hot Water Temperature Control 4 Central Heating System P...

Page 5: ...al heating neon will extinguish Fig 5 Neons 6 to 11 will illuminate as the temperature rises 5 Position ii In this position hot water will be provided when a tap or shower is turned on Fig 8 The hot water neon will illuminate Fig 5 6 The boiler will light automatically on demand 7 The orange burner on neon will illuminate when the boiler is operating and the main burner is on Fig 5 IMPORTANT When ...

Page 6: ...ht or when incomplete lighting of the burner occurs Fig 11 2 Turn the selector switch fully anti clockwise against the spring pressure to the reset position hold for 2 seconds and release Fig 12 Set the selector to the required position to light the boiler 3 If the flame failure light illuminates repeatedly a fault is indicated Your Service Engineer should be contacted as soon as possible 3 4 Safe...

Page 7: ...tem pressure drops below the minimum requirement Fig 12 2 Check the pressure gauge as descibed in Section 3 9 If the pressure is in the normal range a pump fault is indicated Contact your Service Engineer to determine the nature of the fault 3 7 Sensor Fault 1 When the or neon is illuminated a fault on the hot water or central heating temperature sensor is indicated Fig 12 Contact your Service Eng...

Page 8: ...or long periods during cold weather the boiler and whole system should be drained unless there is additional frost protection 3 Your installer will advise you about frost protection and draining the system IMPORTANT When the selector switch is in the 0 Off position the electrical supply to the boiler is isolated The boiler will not operate and the integral timer if fitted will require resetting on...

Page 9: ...rances are kept The compartment should be large enough to house the boiler and ancillary equipment only 5 IT SHOULD NOT BE USED AS A STORAGE CUPBOARD 4 2 Check List 1 If a fault develops or is suspected call your Service Engineer as soon as possible 2 Go through the following check list before you make contact a Is the electricity supply on b Is the selector switch on giving a green Power ON neon ...

Page 10: ...ler will usually be the responsibility of the Installer during the guarantee period after which spare parts may be obtained through approved Potterton stockists if required 2 Quote the appliance name model number and where possible the part number when ordering spares A parts list is included in the Installation and Servicing Instructions 3 The name model number and serial number can be found on t...

Page 11: ...6 0 Notes 11 ...

Page 12: ...Potterton Baxi UK Limited Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 www baxi com Comp No 249108 Iss 1 3 01 922 048 1 ...

Reviews: